{"title":"Design considerations for robust suspension-based microfluidic systems for biomedical applications","authors":"B. Mustin, B. Stoeber","doi":"10.1109/IMS3TW.2008.4581610","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581610","url":null,"abstract":"Polymer microspheres are commonly used in microfluidic devices for biomedical applications. However, the presence of these particles can compromise the reliable operation of the microfluidic devices, as particles have been observed to deposit successively until they block a flow passage, which then leads to device failure. This paper presents investigations of the mechanics of particle deposition to give a better understanding of the process leading to subsequent device failure. Our measurements and observations show that commercially available suspensions can have a high polydispersity, and that a low concentration of relatively large particles can have a major effect on the mean time to failure of a microchannel through blockage by particles.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130235473","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A droplet routing technique for fault-tolerant digital microfluidic devices","authors":"Xiao Zhang, F. van Proosdij, H. Kerkhoff","doi":"10.1109/IMS3TW.2008.4581596","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581596","url":null,"abstract":"Efficient droplet routing is one of the key approaches for realizing fault-tolerant microfluidic biochips. It requires that run-time diagnosis and fault recovery can be made possible in such systems. This paper describes a droplet routing technique for a fault-tolerant digital microfluidic platform. This technique features handling of many microfluidic operations simultaneously and uses on-chip sensors for diagnosis at run-time. Once a fault is detected during the droplet routing, recovery procedures will be started-up immediately. Faulty units on the chip will be marked and isolated from the array so that the remaining droplets can still be routed along a fault-free path to their destinations. This method guarantees a non-stop fault-tolerant operation for very large microfluidic arrays.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125446244","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Asquini, F. Badets, S. Mir, J. Carbonéro, L. Bouzaida
{"title":"PFD output monitoring for RF PLL BIST","authors":"A. Asquini, F. Badets, S. Mir, J. Carbonéro, L. Bouzaida","doi":"10.1109/IMS3TW.2008.4581625","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581625","url":null,"abstract":"With devices operating at ever increasing speed, high resolution RF circuit performances are rapidly becoming non measurable even with the use of RF dedicated testers at affordable costs. This work deals with the development of BIST techniques for RF PLLs. Our aim is to find test measures that are highly correlated to performances that are too costly to measure on-chip and/or on-tester, in order to reduce test time and resources for production test while maintaining standard quality. A BIST output is typically a Go/No-Go output digital signal (most often associated with a structural test). In this work, we will consider as BIST outputs low frequency outputs from embedded monitors (BIST sensors) that can be used by the tester for the evaluation of circuit performances by means of regression functions (Alternate Test). In particular, we will consider monitoring the output of the phase frequency detector (PFD) for PLL BIST purposes. Our case-study is a 65 nm CMOS RF PLL designed and manufactured at ST Microelectronics.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132570749","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Nojeh, P. Pande, A. Ganguly, S. Sheikhaei, B. Belzer, A. Ivanov
{"title":"Reliability of wireless on-chip interconnects based on carbon nanotube antennas","authors":"A. Nojeh, P. Pande, A. Ganguly, S. Sheikhaei, B. Belzer, A. Ivanov","doi":"10.1109/IMS3TW.2008.4581628","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581628","url":null,"abstract":"Design technologies for integrated systems beyond the current CMOS era will present unprecedented advantages such as very high device densities and challenges such as soaring power dissipation issues. Most of the research effort in the emerging area of nanoelectronics has revolved around creating novel devices to replace the traditional CMOS transistor. The development of higher-level communication architectures necessary for integrating such devices into high performance systems has not received the same level of attention so far. With the current trend of CMOS scaling, traditional planar metal-based on-chip interconnect schemes are projected to be the principal bottleneck in meeting the performance needs and specifications of Systems on Chip (SoCs). Three-dimensional integration and on-chip optical and RF communication links have been envisioned as promising alternatives. In this paper we explore the possibility of having an on-chip wireless communication infrastructure using carbon nanotube antennas operating in optical frequencies, and the effect of variations in nanotube properties on the communication behavior.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129364921","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Adaptive ZPETC method for dual-stage actuator controller design in miniaturized optical disc drive","authors":"S. Cheng, Po-Chien Chou","doi":"10.1109/IMS3TW.2008.4581603","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581603","url":null,"abstract":"A swing-arm/PZT dual-stage actuator is designed to provide high performance solution to realize precise tracking and focusing operation of miniaturized optical disc drive (mini-ODD). Because of its dual-stage mechanical characteristics can perform the focusing action smoother and more precise for better fault and error tolerance, the servo system to control such a dual-stage system tends to be more effective than a conventional single-stage ODD system. However, it is not enough to restrain the unwanted outside disturbance. Therefore, the zero phase error tracking controller (ZPETC), as proposed by Tomizuka (1987), which is very sensitive to improve the modeling error in motion control is used for this dual-stage miniaturized actuator. This paper presents an adaptive ZPETC method in dual-stage actuator design to achieve better focusing performance.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122114496","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Picosecond delay adjustment for 12.8 Gbps multiplexed testing","authors":"D. Keezer, D. Minier, P. Ducharme","doi":"10.1109/IMS3TW.2008.4581626","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581626","url":null,"abstract":"A novel high-bandwidth adjustable delay circuit is described that is used for XOR-based multiplexing of multi-Gbps test signals. By precisely-aligning the phase offset of two 6.4 Gbps ATE signals, an Indium-Phosphide exclusive-OR gate is used to synthesize a double-data-rate signal with picosecond resolution and ~30 ps accuracy. The delay circuit is based on an experimentally-observed second-order effect in a SiGe variable-amplitude differential buffer. A 2-channel module for testing serial and parallel signals up to 12.8 Gbps is described. The performance of the module is demonstrated between 6.4 Gbps and 12.8 Gbps.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114560547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A carrier platform for microfluidics research and prototyping","authors":"R. Mallard","doi":"10.1109/IMS3TW.2008.4581594","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581594","url":null,"abstract":"The technology of microfluidics has the potential to revolutionize the way in which a wide range of analytical and diagnostic tests are implemented in applications ranging from genomics to healthcare to environmental monitoring. The translation of innovation in microfluidic devices developed through academic research into actual applications is greatly facilitated by the availability of a prototyping platform, through which a proof-of-concept microsystem can be rapidly and efficiently prototyped. We present a description of a platform developed by CMC Microsystems and its academic research partners for the development of microsystem prototypes employing microfluidic technology. Implementing such a platform in a modular configuration is one means of addressing the diversity of functional requirements driven by the wide range of microfluidic research interests. The challenge of the developing such a platform is strongly concerned with defining not only a physical layout, but also the interfacial standards between the platform modules. The prototyping environment we describe is termed a ldquoCarrier Platformrdquo as it provides a standard for carrying the various microfluidic devices and signals which comprise the system function.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126535083","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Simultaneous optical and fluorescent microscopic measurement of drug retention in single cancer cells","authors":"Yuchun Chen, P.C.H. Li","doi":"10.1109/IMS3TW.2008.4581629","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581629","url":null,"abstract":"A single cancer cell was isolated and captured by a microfluidic single-cell biochip. The chip was made of glass and was fabricated by standard photolithography and wet etch process. Simultaneous optical observation and fluorescent measurement were achieved on the captured cancer cell. This was achieved by using red light to observe the cell; whereas the green fluorescent emission was measured photometrically to monitor the drug concentration. A CCD camera was used to image the cell morphology. At the same time, a PMT detector was used to monitor the cellular drug concentrations change in the single cell as a decrease in the cellular fluorescence intensity. Kinetic information of drug concentration change was obtained by analyzing the real time PMT data. This experiment revealed that during the efflux process, the anti-cancer drug (daunorubicin, DNR) decreased as the drug was pumped out of the cell because of multidrug resistance. The reversal effect of a multidrug resistance inhibitor (Sodium orthovanadate, OVN) on the cellular drug retention in single cancer cells was examined in this study. It was found that a higher cellular DNR concentration was resulted when OVN was present.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128099551","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluation of a fully electrical test and calibration method for MEMS capacitive accelerometers","authors":"N. Dumas, F. Azais, F. Mailly, P. Nouet","doi":"10.1109/IMS3TW.2008.4581616","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581616","url":null,"abstract":"This paper presents an evaluation of a fully electrical test and calibration method for MEMS capacitive accelerometers. The method is based on analytical expressions of the sensitivity that involve both physical parameters of the structure and electrical test parameters. To evaluate the method, an accelerometer has been designed under the Coventor environment and a nodal model parameterized with the material properties and the dimensions of the structure has been built. This model permits to perform low-level fault injection by varying the material properties and the geometrical parameters. Both global and intra-die mismatch variations can be considered. Results show that the proposed method shows the potential for testing sensitivity variations due to process scattering and permits to reduce the sensitivity dispersion after calibration. However, the improvement factor strongly depends on the characteristics of the population.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"66 11","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114135659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design for testing SU-8 and PDMS based hybrid glucose sensor","authors":"J. Patel, B. Kaminska, B. Gray, B. Gates","doi":"10.1109/IMS3TW.2008.4581612","DOIUrl":"https://doi.org/10.1109/IMS3TW.2008.4581612","url":null,"abstract":"In this paper, a test method for testing SU-8 and PDMS based hybrid glucose sensor with gold electrodes sandwiched between the two SU-8 layers is presented. Poly dimethylesiloxane (PDMS) and SU-8 is used as a flexible and bio-compatible sensor substrate material. Furthermore, SU-8 and PDMS is optically transparent and haemocompatible which is very important for implantable sensors. Different methods for testing glucose sensors are mentioned in a separate section. These test methods are categorized in different sections namely, material related tests, fabrication related tests, electrochemical related test and glucose response tests. And each test section is sub-categorized in appropriate sub-sections. The bottom PDMS layer of the sensor is ~500 mum thick and both SU-8 layers are ~100 mum. Each sensor chip is 5.5 mm X 10.5 mm in size with 2 mm X 3 mm for the actual sensor area. Resistance of the successfully fabricated gold electrodes is measured between 1 to 5 mOmega. The drift of the sensors are measured using phosphate buffer followed by the linearity test using the glucose solution.","PeriodicalId":378286,"journal":{"name":"2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121096264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}