Lei Yan, Xiaodong Zhou, Lu Lu, Arthur G. Centeno, L. Kuan, M. Hawrylycz, M. Larimer, G. Rosen, Robert W. Williams
{"title":"Global exploratory analysis of massive neuroimaging collections using Microsoft Silverlight PivotViewer","authors":"Lei Yan, Xiaodong Zhou, Lu Lu, Arthur G. Centeno, L. Kuan, M. Hawrylycz, M. Larimer, G. Rosen, Robert W. Williams","doi":"10.1109/BSEC.2011.5872323","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872323","url":null,"abstract":"Microsoft Silverlight PivotViewer is a web service architecture that provides fluid access to massive image databases using digital zoom image technology. The Pivot interface models some aspects of human vision, with the ability both to perform a global scan and to rapidly focus on the finest details. The inclusion of many levels of metadata in an XML file makes it possible for clients to rapidly re-sort and filter images on the web in ways that are powerful and highly informative. We have used Pivot to restructure a very large collection of histological images (2D) taken from the Mouse Brain Library (MBL, www.mbl.org). The new Pivot system (mbl.pivotcollections.org) can be subdivided, filtered, and sorted using a range of continuous and discrete metadata variables (sex, age, strain, genotype, behavior). The current implementation is optimized for visualization, but does not yet have analytic or annotation tiers that would enable facile quantitative dissection of image collections.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129629421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Marc O. Griofa, Rebecca S. Blue, Robert Friedman, K. Cohen, Philip Hamski, A. Pal, R. Rinehart, T. Merrick
{"title":"Radio Frequency Impedance Interrogation monitoring of hemodynamic parameters","authors":"Marc O. Griofa, Rebecca S. Blue, Robert Friedman, K. Cohen, Philip Hamski, A. Pal, R. Rinehart, T. Merrick","doi":"10.1109/BSEC.2011.5872326","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872326","url":null,"abstract":"Non-contact, non-invasive monitoring of hemodynamic parameters has long been deemed to be important to medical monitoring in a variety of environments. Radio Frequency Impedance Interrogation (RFII) measures hemodynamic function via resonance frequency coupling to a hydrophilic protein molecule. We examined the use of RFII for hemodynamic monitoring of human subjects during Lower Body Negative Pressure (LBNP) and physiological hemodynamic maneuvers using valsalva and orthostatic position changes in this small pilot study. Results demonstrate a high degree of correlation between stroke volume waveform amplitude (R2 = 0.92) and RFII derived R-R interval (R2 = 0.99) and classic electrocardiogram (ECG). These results suggest that RFII may be of great utility in the pre-hospital triage setting and for in-hospital patient monitoring.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130491510","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Multiparameter physiological signal reconstruction using NARX Neural Networks","authors":"R. Wham, Xiaopeng Zhao","doi":"10.1109/BSEC.2011.5872316","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872316","url":null,"abstract":"Constant monitoring of a variety of physiological signals is vitally important in numerous clinical care settings. This signals are not perfect, however, and can be corrupted or lost. The loss of a signal can be devastating to the patient, as the physician may lose key information to understanding disease processes, or worse, be unaware of the patient's status in either surgery or the ICU. This study uses a NARX-type Artificial Neural Network to reconstruct portions of physiological signals that have become corrupted. The effectiveness of this network was tested using signals and guidelines from the Computing in Cardiology/Physionet 2010 challenge, “Mind the Gap.” The NARX network performs quite well under these conditions, comparing favorably with other top entrants in the Physionet competition. Additionally, it is noted that the accuracy of the signal reconstructions also depends on which channel was corrupted. This work has important implications in many areas ranging from sports medicine and sleep studies to surgery and the ICU.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126316808","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of crosslinked silica aerogels for implant applications","authors":"F. Sabri, J. Cole, M. Scarbrough, N. Leventis","doi":"10.1109/BSEC.2011.5872330","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872330","url":null,"abstract":"Silica-based Aerogels have a number of unique properties that make them suitable for a range of applications. These include superior thermal, acoustic, and electrical insulation capabilities, all associated with the highly-porous nature of this class of materials. Crosslinked (X) silica aerogels have improved mechanical and surface properties making them suitable for biomedical device applications, particularly in the peripheral regions of the body. Aerogel's ability to dampen sounds waves is particularly important since it would allow an external non-invasive imaging technique for aerogel based implants. The biocompatibility of this class of material must be addressed prior to the development of in vivo imaging data. In this work, the authors report on the growth and interaction of Opossum Kidney cells and dorsal root ganglia on crosslinked silica aerogels, paving the way for implant applications.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125592713","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E. Brodsky, W. Block, Andy L. Alexander, M. Emborg, C. Ross, Karl A. Sillay
{"title":"Intraoperative device targeting using real-time MRI","authors":"E. Brodsky, W. Block, Andy L. Alexander, M. Emborg, C. Ross, Karl A. Sillay","doi":"10.1109/BSEC.2011.5872335","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872335","url":null,"abstract":"Real-time MRI has the potential to significantly improve intraoperative surgical processes. However, development of these technologies is complicated by the need for software tools that support task-oriented visualization of 2D and 3D datasets, enable flexible real-time image processing pathways, and interface with proprietary scanner hardware. Developing such tools requires substantial software engineering effort for these low-level tasks that distracts from a focus on developing and implementing algorithms that relate to the surgical technique in question. RTHawk and Vurtigo are extensible software platforms that simplify the development of tools for performing real-time MRI-guided procedures. We present here initial work on a system for performing intracerebral drug infusion under real-time MRI guidance using the Navigus pivot point-based MRI-compatible external trajectory guide. Initial testing performed using a GE scanner targeting a rigid object in a water-filled phantom allowed realtime aiming and infusion monitoring with 1 mm targeting accuracy. In vivo testing is forthcoming.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121518823","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ann Wells, S. Bewick, K. Kruse, R. Ward, J. Biggerstaff
{"title":"Modeling the effect of soluble fibrin on the immune-tumor interaction","authors":"Ann Wells, S. Bewick, K. Kruse, R. Ward, J. Biggerstaff","doi":"10.1109/BSEC.2011.5872324","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872324","url":null,"abstract":"Cancer is the second leading cause of death in the United States. It is believed that many people develop cancers in their lifetime but the immune system kills these cells without the need for outside treatments. In cancer progression, however, tumor cells may evade the immune system by a mechanism that is not fully understood. Soluble fibrin (sFn), a marker for disseminated intravascular coagulation, may play a role in evasion by tumor cells. As sFn becomes the predominant substance of the matrix surrounding the tumor cells it becomes immunosuppressive. This change from a predominantly collagen matrix to a sFn matrix could play a major role in tumor evasion. Previous research has shown that when sFn is present during the immune-tumor interaction monocyte receptors (MAC-1 and LFA-1) that, interact with CD54 on the tumor cell are altered. When sFn is bound to CD54 the LFA-1 receptor can no longer bind to the tumor cell, however, MAC-1 is still functional. If sFn binds to both, MAC-1 and CD54, then the monocyte is no longer functional against the tumor cell. A mathematical model was developed using a series of scenarios to create a set of continuous ordinary differential equations. These equations were coded in MATLAB to obtain simulations. Parameters were altered to show that the equations validated the experimental research previously published.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128932132","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Validation of a 3D hidden-Markov model for breast tissue segmentation and density estimation from MR and tomosynthesis images","authors":"Christina M. Shafer, V. Seewaldt, Joseph Y. Lo","doi":"10.1109/BSEC.2011.5872317","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872317","url":null,"abstract":"Breast cancer is the most common non-skin cancer and the second leading cause of cancer-related death in women here in the United States. Mammography is the current standard clinical imaging modality for breast cancer screening and diagnosis, and mammographic breast density (i.e. the percentage of the entire breast volume that is taken up by dense glandular tissue) has been shown to be a biomarker well correlated with cancer risk. However, a mammogram is limited by its projective nature, and its quantitative abilities would likely be surpassed by 3D imaging modalities. This study plans to extract quantitative 3D breast tissue density information using a fully automatic probabilistic model trained on pre-segmented MRIs. This model “ground truth” was obtained from MRIs for 293 breasts by iterative threshold-based voxel value classification. Before model training/testing, all images were processed to optimize the available range of values for this breast tissue segmentation task. After training a 3D hidden Markov model (HMM) on 10 segmented “ground truth” MR images, our model was validated by segmenting the remaining 283 breasts. Initial training/testing of the HMM on MRIs matched density to thresholding within 5% for 99/283 breasts and 10% for 171/213 breasts. After the same task-based value optimization method was applied to digital breast tomosynthesis (“tomo”) images, the same trained HMM was tested to segment tomo volumes of subjects with at least one MRI for validation. HMM segmentation was qualitatively superior at the most cranial/caudal slices in MRIs and quantitatively superior when tested across modalities. Its robustness and ease of modification give the HMM great promise and potential for expansion to more novel 3D breast imaging modalities like breast tomo.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123225085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Firjani, A. Elnakib, F. Khalifa, G. Gimel'farb, M. A. El-Ghar, Adel Said Elmaghraby, A. El-Baz
{"title":"A new 3D automatic segmentation framework for accurate extraction of prostate from diffusion imaging","authors":"A. Firjani, A. Elnakib, F. Khalifa, G. Gimel'farb, M. A. El-Ghar, Adel Said Elmaghraby, A. El-Baz","doi":"10.1109/BSEC.2011.5872329","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872329","url":null,"abstract":"Prostate segmentation is an essential step in developing any non-invasive Computer-Assisted Diagnostic (CAD) system for the early diagnosis of prostate cancer using Magnetic Resonance Images (MRI). In this paper, a novel framework for 3D segmentation of the prostate region from Diffusion-Weighted Magnetic Resonance Imaging (DW-MRI) is proposed. The framework is based on a Maximum the Posteriori (MAP) estimate of a new log-likelihood function that consists of three descriptors: (i) 1st-order visual appearance descriptors of the Diffusion-MRI, (ii) a 3D spatially rotation-variant 2nd-order homogeneity descriptor, and (iii) a 3D prostate shape descriptor. The shape prior is learned from the co-aligned 3D segmented prostate Diffusion-MRI data. The visual appearances of the object and its background are described with marginal gray-level distributions obtained by separating their mixture over prostate data. The spatial interactions between the prostate voxels are modeled by a 3D 2nd-order rotation-variant Markov-Gibbs Random Field (MGRF) of object/background labels with analytically estimated potentials. Experiments with real in vivo prostate Diffusion-MRI confirm the robustness and accuracy of the proposed approach.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123094402","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A finite element analysis and experimental study of human edentulous mandible","authors":"Yi-Min Yang, P. Rahmanivahid, W. Xu, A. Crocombe","doi":"10.1109/BSEC.2011.5872334","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872334","url":null,"abstract":"By the means of finite element analysis (FEa), biomechanical behaviors of human mandible have been widely studied over decades. Many different types of simulation of muscle forces have been employed in studies to increase the reality of mastication environment. Among these studies, Cruz et al (2003)'s[1] calculation of muscle forces was well accepted. However, these simulations have not been verified experimentally as seen in literatures. In this study, a three dimensional (3D) finite element model of human mandible was created from CT images of a cadaver mandible bone. 4 pairs of muscle forces was applied to this 3D model based on a calculation by using Cruz et al (2003)'s method. The exact cadaver bone was used in an experimental testing rig to evaluate strain distribution and, hence, to verify the results of FEa. A set of different sizes of loads which matches with the one used in FE study was applied to the cadaver bone. Strain gauges were employed to gain data of strain distribution on the bone. The experimental result shows that the trend of stress/strain during increase or decrease of muscle forces coincides with FE result. This verifies the masticator muscle force calculation of Cruz et al (2003) to be correct.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"10 7","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131868738","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. McBride, S. Zhang, M. Wortley, M. Paquette, G. Klipple, E. Byrd, L. Baumgartner, X. Zhao
{"title":"Neural network analysis of gait biomechanical data for classification of knee osteoarthritis","authors":"J. McBride, S. Zhang, M. Wortley, M. Paquette, G. Klipple, E. Byrd, L. Baumgartner, X. Zhao","doi":"10.1109/BSEC.2011.5872315","DOIUrl":"https://doi.org/10.1109/BSEC.2011.5872315","url":null,"abstract":"Osteoarthritis is a degenerative joint disease, which causes the degradation of articular cartilage and subchondral bone. The disease may result in mechanical abnormalities of the joints, including weight bearing joints such as the knees and hips. In this work, we analyze gait biomechanical data using neural network models to predict the level of joint deterioration and the level of pain in participants suffering from knee osteoarthritis. The results of the analyses demonstrate strong correlation between gait kinetics and joint deterioration and level of pain in osteoarthritic individuals.","PeriodicalId":377652,"journal":{"name":"Proceedings of the 2011 Biomedical Sciences and Engineering Conference: Image Informatics and Analytics in Biomedicine","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126133638","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}