{"title":"Photoacoustic imaging of a biological sample using in-phase-sum focus algorithm","authors":"W. Cai, Z. Tang, D. Xing","doi":"10.1117/12.403983","DOIUrl":"https://doi.org/10.1117/12.403983","url":null,"abstract":"Photoacoustic (PA) imaging is a new imaging modality, which converts pressure signals received by an array of transducers to a regional distribution of electromagnetic absorption density. In this paper we present an experiment result of a photoacoustic imaging to depths of approximately 3mm for a fabricated absorber within a real tissue, using a 1064-nm pulse YAG laser. The time-resolved stress detection technique was used for PA signal detection and an in-phase- sum-focus algorithm was used for image reconstruction. To obtain excellent temporal resolution, a wideband PVDF membrane hydrophone and a fast-digitizing oscilloscope was used for time-resolved detection of PA signals. A computer controlled translation stage on which the sample cell was fixed was used to a 2D scanning mode. Images of different depth profile was obtained with a lateral and depth resolution of approximately 0.5mm.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116968646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Introduction to photon traditional Chinese medicine","authors":"Song-hao Liu, T. Liu, Yan Li, Yaoyong Meng","doi":"10.1117/12.403969","DOIUrl":"https://doi.org/10.1117/12.403969","url":null,"abstract":"Photon traditional Chinese medicine (PTCM), and inter- discipline of photonics and traditional Chinese medicine (TCM), studies TCM, such as the diagnostics, therapeutics, indistinct disease theory, rehabilitation, health care and so forth, by using photonics. IN this paper, we will give an introduction of PTCM and review its progress in the collective interaction of low intensity laser irradiation with biological systems, the propagation of low intensity laser irradiation through tissue, the biophotonics representation of acupoint, low intensity laser therapy, TCM laser hemotherapy, laser acupuncture. In this paper, the concept of biological unit was put forward for acupoint and cell membrane receptors to be considered as an identical particle model. The interaction of identical particles was studied by quantum chemistry, as well as the response of the system interacting with physical factors by the time quantum theory on radiation-matter interaction. It was shown that the identical particles from coherent states, the response rate of the super-change state is a linear function of N2 and N3 (N is the particle number), and the one of the sub-change state is zero. Its application led to the explanation of the contribution of biological unit number of acupoint to acupoint specificity and the contribution of cell membrane receptors to low in tensity laser irradiation. The comparative research of acupoint effect and cell function with biophoton emission showed that acupoint states and the membrane receptor state are related to body diseases.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117136586","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yonghong He, D. Xing, Yong Yao, Yonghong Tang, Shici Tan, K. Ueda
{"title":"Enhanced sonoluminescence of tissues","authors":"Yonghong He, D. Xing, Yong Yao, Yonghong Tang, Shici Tan, K. Ueda","doi":"10.1117/12.403982","DOIUrl":"https://doi.org/10.1117/12.403982","url":null,"abstract":"In this paper, biological sonoluminescence (SL) of different tissues was investigated for the first time. Tissue samples (muscle, liver and fat) were prepared and put into a column- shaped ultrasound field. A photomultiplier tube and a back- illuminated cooled CCD were used to detect the SL signal. In the experiments, FCLA (Fluoresceinyl Cypridina Luminescent Analog) was used to enhance SL. With the chemiluminescence technique, we suggest that the biological SL mainly come from the free radicals produced by the ultrasound cavitation, which is different from the mechanism of the SL in aqueous solutions.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"352 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123406547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"New doughnut mode for optical tweezers and spanners","authors":"Chunqing Gao","doi":"10.1117/12.403920","DOIUrl":"https://doi.org/10.1117/12.403920","url":null,"abstract":"The doughnut mode is of great importance in optical tweezers and spanners. Such mode is generated by transforming the Hermite-Gaussian mode of a laser-diode end-pumped Nd:YAG laser through a rotated cylindrical lens system. The field distribution and the intensity profile of the doughnut mode were calculated theoretically from the field of the input Hermite-Gaussian mode. The beam transformation was confirmed in the experiments.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126721539","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Functions of laser light, laser-absorbing dye, and immunoadjuvants in photodynamic immunotherapy","authors":"Wei R. Chen, Hong Liu, K. Bartels, R. Nordquist","doi":"10.1117/12.403939","DOIUrl":"https://doi.org/10.1117/12.403939","url":null,"abstract":"Photo Dynamic Immuno Therapy (PDIT) is a novel approach for treatment of metastatic tumors. It involves an intratumor administration of a laser-absorbing dye and an immunoadjuvant, followed by a non-invasive laser irradiation. Previous studies using a novel immunoadjuvant, glycated chitosan, showed the effect of the treatment on a metastatic breast tumor in rats, including the eradication of treated primary tumors, regression of untreated metastases, and the evidence of immune responses induced by the treatment. To further understand the mechanism of PDIT, tumor-bearing rats were treated by different combinations of the three PDIT components. The rat survival rates and profiles of primary and metastatic tumors, after treatment by individual component and different combinations of components, were analyzed. All the experimental groups without using immunoadjuvant showed none or little positive effect. The use of glycated chitosan, either by itself or in combination of other components, has showed that among the concentrations of 0.5%, 1% and 2%, glycated chitosan was most effective at 1% in PDIT. Another immunoadjuvant, incomplete Freund's adjuvant, was also used and the results were compared with that of using glycated chitosan. PDIT was applied to a different tumor model- Met-Lu, a prostatic tumor with lung metastases in male rats and the preliminary results are reported.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"119 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116383963","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Mathematical modeling and fiber optics parameter optimization in diagnostics of biotissue by PNC method","authors":"A. Sokolovsky, V. Masychev","doi":"10.1117/12.403946","DOIUrl":"https://doi.org/10.1117/12.403946","url":null,"abstract":"Optical PNC-diagnostics is one of the methods to diagnose biotissue in norm and pathology. In primary case backscattering and fluorescent components of detected secondary radiations are registered by means of PNC-method. These radiations are stimulated and occur when probing laser beam radiates biotissue. For diagnostic purposes both monofibers and multifiber probes (fiber bundle), where probing radiation transmits to biotissue via one of the fibers, are usually used. Registered secondary radiations from biotissue are detected by distal end of a multifiber probe (peripheral fibers). This work was intended to mathematically modulate and determine optimization parameters of fiberoptic probes, applied in PNC-diagnostics inclusive localization and depth of pathological underskin hearth. Main mathematical correlations and formulas for calculation and optimization of backscattering radiation in dependence on applied waveguide characteristics inclusive radiation absorption in biotissue were obtained. All calculations are made regarding each biotissue layer as reflective or Lambert quasi-source of backscattering signal. It is found out, that varying parameters in a probe we can vary the depth of tissue where the maximum signal received from and optimize the value of the signal.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121952037","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Rong Yang, Guoliang Huang, Jing Cheng, Minxian Wu, Guofan Jin
{"title":"Confocal scanning fluorescence detection system and its optimization","authors":"Rong Yang, Guoliang Huang, Jing Cheng, Minxian Wu, Guofan Jin","doi":"10.1117/12.403993","DOIUrl":"https://doi.org/10.1117/12.403993","url":null,"abstract":"Fluorescence detection by confocal scanning systems has advantages of large area detection, small focus depth, large numerical aperture, complete laser rejection, low background noise, high sensitivity and S/N ratio. It is a sensitive and precise method to record and analyze results of biological or biomedical assay, such as DNA hybridization assay or micro capillary electrophoresis assay on biochip. Parameters like power of laser or sensitivity of PMT are responsible for signal to noise ration and sensitivity of the system, which should be optimized relative to different situations. The structural design and experimental analysis on parameter optimization of a confocal scanning fluorescence detection system are presented in this paper.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134541981","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Michael L. Stachanov, V. Masychev, L. Velsher, V. Kirkin, Roman V. Zhashkov, Emilia A. Kocharian
{"title":"10-year experience of CO2-laser application in ambulance gynecology","authors":"Michael L. Stachanov, V. Masychev, L. Velsher, V. Kirkin, Roman V. Zhashkov, Emilia A. Kocharian","doi":"10.1117/12.403945","DOIUrl":"https://doi.org/10.1117/12.403945","url":null,"abstract":"CO2-laser surgical systems have come to stay in everyday practice of modern physicians and are successfully used in colposcopic and laparoscopic surgery. Results, obtained in ambulance gynecology are especially impressing. CO2- laser provides high medical- and cost-effective treatment. Presented work describes many-years experience of CO2- laser application. 439 patients with various vulvaric and cervix diseases were operated within this period. Laser beam parameters were selected according to requirements ((tau) =4 J/cm2) treatment without carbonization. Analyses of the results showed that the laser successfully destructs uterine cervix erosion, endocervicosis, dysplasia, leukoplakia, eritoplakia of uterine cervix, various benignant pathologies and focus degenerative process in ambulate conditions.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"6 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134392112","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"X-ray source with microbeam","authors":"Kaige Wang, H. Niu","doi":"10.1117/12.403951","DOIUrl":"https://doi.org/10.1117/12.403951","url":null,"abstract":"A novel x-ray source with micro-beam which has high brightness and micrometers or sub-micrometers micro-focus comprise primarily emitting system, focusing system, and permutable metallic foil targets. In this paper, the axial potential of system has been calculated by means of Boundary element method (BEM) and the electronic trajectory was traced by Runge-kutta method, respectively. The results show that when the temperature of LaB6 cathode is about 1900K and it was set behind the Wehnelt grid accurately and correctly, with partial pressures being kept below 10-7 torr, micro-focus electron-beam (60 microampere current) focused onto the face of target adapts to the producing x-ray micro- beam requirement.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133812496","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Insoluble components in human gallstones by Raman and IR spectroscopy","authors":"Gang Liu, D. Xing, Huai-min Gu","doi":"10.1117/12.403980","DOIUrl":"https://doi.org/10.1117/12.403980","url":null,"abstract":"Human gallstones were immersed with chloroform, ethanol and ether. The insoluble components were studied by normal Raman (SER) and FT-infrared (IR) spectroscopy. The results show that bilirubinate salts and proteins are the main components in the insoluble materials of gallstones. The secondary structure of the proteins in gallstones are dominated by (alpha) -helix structure. The results suggest that proteins play a key role in the formation of gallstones.","PeriodicalId":376509,"journal":{"name":"Optics and Optoelectronic Inspection and Control","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114409497","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}