2023 12th Asia-Pacific International Conference on Lightning (APL)最新文献

筛选
英文 中文
Transient Overvoltage Response of Photovoltaic Panels to Lightning Impulse: Experimental Observations and Analysis 光伏板对雷电冲击的瞬态过电压响应:实验观察与分析
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181419
Ibrahim Hetita, A. S. Zalhaf, D. Mansour, Yang Han, P. Yang, Congling Wang
{"title":"Transient Overvoltage Response of Photovoltaic Panels to Lightning Impulse: Experimental Observations and Analysis","authors":"Ibrahim Hetita, A. S. Zalhaf, D. Mansour, Yang Han, P. Yang, Congling Wang","doi":"10.1109/APL57308.2023.10181419","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181419","url":null,"abstract":"In recent years, the utilization of solar energy systems for electricity generation has increased. This is attributed to the fact that they are environmentally friendly and sustainable sources of energy, unlike the limited supply of fossil fuels. Among the various forms of solar energy, photovoltaic (PV) cells are a significant means of generating electricity directly from the sun. However, since PV arrays are typically installed in outdoor areas, they are vulnerable to lightning strikes resulting in transient overvoltage, which can lead to equipment failure and potential safety hazards. Therefore, it is crucial to implement an efficient protection system to prevent lightning strikes and assess the transient performance of PV systems during such occurrences. This paper presents experimental observations and analysis of the transient overvoltage response of PV panels under lightning impulse conditions. The experiments are conducted using an impulse generator that allowed for the controlled application of lightning impulse to a small-scale PV panel. The transient overvoltage response is recorded using high-speed data acquisition systems. The experimental results showed that the transient overvoltage response of the PV panels was affected by several factors, including changing the measuring point location, the impulse voltage value, the earthing resistance value, and the earthed leg. Furthermore, an analysis of the experimental data was conducted to identify the underlying mechanisms responsible for the observed transient overvoltage behavior. The experimental observations and analysis presented in this paper provide valuable insights into the transient overvoltage response of PV panels under lightning impulse conditions. The results can be used to develop appropriate protective measures to minimize the risk of equipment failure and ensure the safe and reliable operation of PV systems.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123360231","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of the Electromagnetic Field (EMF) Distribution on the Human Body due to Earth’s Potential Rise (EPR) of Different Types of Soil 不同土壤类型对地球电位上升对人体电磁场分布的影响分析
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181900
Siti Nurhidayu Binti Bani Hashim, N. H. Ali, Md Moshiur Rahman, D. Johari, F. A. Haris, M. Z. A. Kadir
{"title":"Analysis of the Electromagnetic Field (EMF) Distribution on the Human Body due to Earth’s Potential Rise (EPR) of Different Types of Soil","authors":"Siti Nurhidayu Binti Bani Hashim, N. H. Ali, Md Moshiur Rahman, D. Johari, F. A. Haris, M. Z. A. Kadir","doi":"10.1109/APL57308.2023.10181900","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181900","url":null,"abstract":"This paper investigates the magnetostatic properties of Earth’s Potential Rise (EPR) distribution caused by a direct lightning strike on the ground, taking into account the specific characteristics of different parts of the human body. The study includes various soil parameters and considers different distances between objects and striking points. To simulate these conditions, a designed model was used in conjunction with finite element software (ANSYS). The simulation results show that lightning striking the soil can significantly increase the current potential around the attachment point, extending to distant parts of the earth due to soil conductivity. To evaluate the potential impact on the human body, the study analyzed the values of the Electromagnetic Field (EMF) and EPR distributions, which can cause injuries or fatalities. Understanding these effects is crucial for developing effective grounding and lightning protection systems. Public safety measures should also be disseminated to reduce the risks posed to humanity. The results of the analysis demonstrate that different soil factors influence the human body in distinct ways. This information can be used to develop more effective safety measures and improve the protection of human life from lightning strikes.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"100 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128587999","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Japanese Industrial Standards Requirements and Performance Evaluation of Lightning Detector for Wind Turbine 日本工业标准风力发电机雷电探测器要求及性能评价
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181802
Yoshito Abe, Koji Inazaki, Kazuma Shinomura
{"title":"Japanese Industrial Standards Requirements and Performance Evaluation of Lightning Detector for Wind Turbine","authors":"Yoshito Abe, Koji Inazaki, Kazuma Shinomura","doi":"10.1109/APL57308.2023.10181802","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181802","url":null,"abstract":"In Japan, Japanese Industrial standards (JIS) for lightning protection for wind turbines is scheduled to be revised and the required performance of lightning detectors for wind turbines will be added. We conduct evaluation tests of a newly developed lightning detector for wind turbines and confirm that it satisfies the performance requirements of JIS. Furthermore, we confirm that the detector can detect and record lightning strikes in an actual installation environment through demonstration tests.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130898174","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Coordinated SPD Systems for Mitigating the Effect of Lightning-Induced Voltage on Hybrid Solar PV-Battery Energy Storage System 缓解雷击电压对混合太阳能-光伏-电池储能系统影响的协调SPD系统
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10182043
N. I. Ahmad, M. A. Ab. Kadir, Z. Ali, M. Osman, M. H. Roslan, N. H. Zaini
{"title":"Coordinated SPD Systems for Mitigating the Effect of Lightning-Induced Voltage on Hybrid Solar PV-Battery Energy Storage System","authors":"N. I. Ahmad, M. A. Ab. Kadir, Z. Ali, M. Osman, M. H. Roslan, N. H. Zaini","doi":"10.1109/APL57308.2023.10182043","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10182043","url":null,"abstract":"This paper discusses the effect of lightning-induced voltage on a hybrid solar photovoltaic (PV)-battery energy storage system (BESS) without an external lightning protection system (LPS). Solar PV generates electricity by converting solar energy and providing it to the user. In addition, battery energy storage is also utilised to supply consistency and satisfy the need for energy. However, because the system is installed in open spaces, lightning has always been a huge difficulty for it to work at optimal efficiency. In this paper, the single SPD Class I was installed near the inverter on the DC side. The study on cable length with various lightning current amplitude and lightning strike distance is conducted. The simulation findings found that the inverter is well protected by the SPD whereby the impulse withstand voltage is 6 kV, however, the solar PV-BESS is affected by the lightning-induced voltage regardless of any cable length. In this way, providing the requirement for an adequate SPD installation will ensure improved maintenance and extend the equipment’s lifespan.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133157352","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Simulation and Analysis on Dynamic Distribution of Space Charge of Wind Turbine Blade Tip Corona Discharge at Different Rotation Angles 风电叶片叶尖电晕放电在不同旋转角度下空间电荷动态分布的仿真与分析
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181324
Qianhui Yang, Yeqiang Deng, Fang Chaoyin, Yu Wang, Chen Xiaoyue, X. Wen, L. Lan, Jun Xu, Shaokang Chen
{"title":"Simulation and Analysis on Dynamic Distribution of Space Charge of Wind Turbine Blade Tip Corona Discharge at Different Rotation Angles","authors":"Qianhui Yang, Yeqiang Deng, Fang Chaoyin, Yu Wang, Chen Xiaoyue, X. Wen, L. Lan, Jun Xu, Shaokang Chen","doi":"10.1109/APL57308.2023.10181324","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181324","url":null,"abstract":"Aiming at the problem of unclear distribution characteristics of space charge near the blade tip of the wind turbine, this paper used the simulation modelling method to simulate corona discharge of the blade tip at different angles. The relative motion between the wind turbine’s blade and surrounding air when the wind turbine rotates is equivalent to the high-speed airflow through the blade tip. A two-dimensional positive space charge distribution model of corona discharge was established considering the attachment and collision between positive ions and other ions. Based on the above model, the blade tip corona discharge was simulated, and the distribution and migration characteristics of positive space charge were obtained when the blades were at different angles. It is found that, under the lightning electric field and high-speed airflow, the transfer velocity of space charge provided by the high-speed airflow flowing through the blade tip is much higher than that provided by electric field traction. Therefore, the transfer and diffusion direction of space charge in the blade tip is mainly determined by the direction of the high-speed airflow at the blade tip. At the same time, the space charge no longer symmetrically distributed in space causes space potential distortion, the potential on the left side (windward side) of the blade tip air-termination is higher than that on the right side at the same height, and the direction of the maximum electric field near the blade tip air-termination shifts to the left, and the electric field amplitude also increases compared with that in the static condition. The work in this paper can provide a basis for the initiation and development calculation of upstream pilot wind turbine blades.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127735319","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Air Terminal Requirement for Offshore Platform’s Vent Stack: Assessment and Mitigation Plans 海上平台排气系统的空气终端要求:评估和缓解计划
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181674
Ir. S Juhaida Yusof, A. L. Maryani
{"title":"Air Terminal Requirement for Offshore Platform’s Vent Stack: Assessment and Mitigation Plans","authors":"Ir. S Juhaida Yusof, A. L. Maryani","doi":"10.1109/APL57308.2023.10181674","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181674","url":null,"abstract":"On a new offshore platform construction project, as part of lightning protection system (LPS), an air terminal (AT) was designed to be installed at the platform’s process vent tip to mitigate potential ignition at that area during coincident existence of hydrocarbon release and lightning occurrence phenomenon. The AT was designed as part of compliance to company’s standardized technical practice on LPS, which is intended to prevent any accidental ignition at the vent tip area that may result in flame getting propagated into the vent system. Calculated hazardous zone radius of 7.01 meters, requires the AT designed height to be approximately 8 meters to ensure it is outside of the hazardous area cloud. This height is deemed impractical. Dimension of the AT contributes to major impact on the vent stack structural design as it leads to additional construction material which results to increase in platform weight. From project execution perspective, this will increase overall cost and lengthen the project execution schedule. Risk assessment was done on not having to install the AT on vent stack and several means are identified to manage the risk through appropriate mitigation plans. These mitigation plans support project management team decision to deviate from company’s standardized technical practice on LPS.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"1 15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127979325","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Lightning Resistance Test and Lightning Protection Safety Design of Glass Curtain Wall 玻璃幕墙耐雷击试验及防雷安全设计
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181323
Jiang Xiong, Huahui Chen, Yifeng Song
{"title":"Lightning Resistance Test and Lightning Protection Safety Design of Glass Curtain Wall","authors":"Jiang Xiong, Huahui Chen, Yifeng Song","doi":"10.1109/APL57308.2023.10181323","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181323","url":null,"abstract":"This paper analyzes the common lightning protection designs of glass curtain wall, and investigates the lightning protection method of non-exposed frame glass curtain wall. Furthermore, we propose the safety equivalence principle of risk and safe and economic lightning protection designs applying to glass curtain wall with various structure types base on the latest lightning tolerance test standard of glass curtain wall as well as the principle of lightning protection.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"44 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128500784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Characteristics of bolt-from-the-blue lightning discharge produced by a thunderstorm in Japan on August 26, 2018 2018年8月26日日本雷暴产生的闪电放电特征
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181852
T. Kudo, Namiko Sakurai
{"title":"Characteristics of bolt-from-the-blue lightning discharge produced by a thunderstorm in Japan on August 26, 2018","authors":"T. Kudo, Namiko Sakurai","doi":"10.1109/APL57308.2023.10181852","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181852","url":null,"abstract":"A thunderstorm that occurred in the Kanto area in Japan, on August 26, 2018, was confirmed to accompany bolt-from-the-blue (BFB) lightning by photographic analysis. To examine the characteristics of BFB lightning flashes caused by this thunderstorm, occurrence frequency, horizontal discharge distance, and direction of discharge progress, quantitative analysis was conducted using lightning mapping array data and extended radar information network (XRAIN) precipitation data for the first time in Japan. This thunderstorm produced 18 BFB flashes. The maximum and average horizontal discharge distance from the edge of the precipitation area were 3,652 m and 1,431 m, respectively. The distance from the edge of the precipitation area and the discharge inception altitude of the BFB flashes seemed to be longer and higher than normal cloud-to-ground (CG) lightning flashes. In particular, the direction of the BFB discharge progress showed a characteristic distribution concentrated on the south side of the thunderstorm and right side of its movement direction. The surface wind around this area flowed from the south side into the thunderstorm. According to XRAIN precipitation data, BFB flashes occur around heavy rain regions (convective region) inside the thunderstorm. The BFB-producing thunderstorm in this study was extremely dangerous because BFB flashes occurred in the opposite direction of the thunderstorm’s movement direction.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115885785","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Estimation of Direct Lightning Flashover Rate of Medium Voltage Distribution lines under Salt Pollution Condition 盐污染条件下中压配电线路直击闪络率估算
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181493
K. Ishimoto, Tomoyuki Sato
{"title":"Estimation of Direct Lightning Flashover Rate of Medium Voltage Distribution lines under Salt Pollution Condition","authors":"K. Ishimoto, Tomoyuki Sato","doi":"10.1109/APL57308.2023.10181493","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181493","url":null,"abstract":"Lightning performance assessment is important to carry out the effective lightning countermeasures for medium voltage distribution lines. And thus, many studies of indirect and direct lightning performance have been carried out. In many studies, the reduction of the flashover voltage due to salt pollution of distribution insulators has not been considered. When the insulator is polluted by salt, flashover voltage of the insulators decreases, and it may cause the increase of the flashover rate due to lightning. In this paper, at first, we show the flashover characteristics of insulators considering the salt pollution. Next, we estimate the direct lightning flashover rate under salt pollution condition by Monte Carlo procedure. The calculation results show that the influence of salt pollution on the flashover rate may be relatively greater in the well-protected distribution lines.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"215 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116827083","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Lightning Behaviour in Beaufort, Sabah 沙巴州博弗特的闪电行为
2023 12th Asia-Pacific International Conference on Lightning (APL) Pub Date : 2023-06-12 DOI: 10.1109/APL57308.2023.10181354
M. Jaafar, M. F. Awang, I. Musirin, M.A.R. Parsat, D. Johari, R. Lim, A. K. Majeed
{"title":"Lightning Behaviour in Beaufort, Sabah","authors":"M. Jaafar, M. F. Awang, I. Musirin, M.A.R. Parsat, D. Johari, R. Lim, A. K. Majeed","doi":"10.1109/APL57308.2023.10181354","DOIUrl":"https://doi.org/10.1109/APL57308.2023.10181354","url":null,"abstract":"This paper presents behaviour of cloud-to-ground (CG) lightning in Beaufort Sabah, Malaysia. The main contribution of this work is to investigate the behavior of cloud-to-ground (CG) lightning in Beaufort by retrieving data from Lightning Detection System (LDS). This is achieved by analyzing data from LDS for three years from year 2020 to 2022 and tabulate them into visual aids. To validate the data, a lightning detection system (LDS) which owned by Sabah Electricity Sdn Bhd (SESB) which consisting of 6 sensors in Sabah state is used to retrieve data for lightning activities in Sabah. From the analysis, it found a total number of 117,113 cloud-to-ground (CG) events in radius of 10km from Beaufort district and the pattern shows the distribution of lightning discharges (CG) for three years are increased from year 2020 to 2022. All these data are important for the purpose of lightning protection for transmission lines tower and line lightning performance in Beaufort area.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124204022","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信