{"title":"Turn to turn fault detection and classification in stator winding of synchronous generators based on terminal voltage waveform components","authors":"M. Fayazi, F. Haghjoo","doi":"10.1109/PSPC.2015.7094926","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094926","url":null,"abstract":"In this paper, a novel method is presented to detect and classify turn-turn faults (TTF) in stator winding of the synchronous generators on the basis of resulting harmonics contents in the terminal voltage waveforms. Analytical results by using Decision Tree (DT) show that this algorithm is practicable using only the first harmonic of residual voltage and only two harmonic component values. Simulations in Maxwell software are done using Fuji's technical documents and data sheets of an actual salient pole synchronous generator (one unit of an Iran's hydroelectric power plants) and all of related parameters (such as B-H curve, unsymmetrical air gap and pole saliency, slot-teeth effect, and so on) are considered to obtain a comprehensive model, without any simplifier assumption.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"167 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123533335","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PMU placement to reduce state estimation bias considering parameters uncertainty","authors":"M. Davoudi, Elssodani Abdelhadi Muhammed","doi":"10.1109/PSPC.2015.7094929","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094929","url":null,"abstract":"In this paper, a novel analysis is performed to determine the bias of Weighted Least Squares (WLS) power system state estimator to find out how much different placements of Phasor Measurement Unit (PMU) will affect the state estimator's bias behavior whereas the network parameters are subjected to different quantities of uncertainties for a given measurement uncertainty. The lack of unbiasedness is an important defect of state estimators hence, for each network parameters uncertainty the bias of state estimator is computed. To determine how much the state estimator is biased, using the classical hypothesis test approach a threshold is assigned. The analysis is simulated on IEEE 14-Bus power network test case. To have an idea about the visualization of bias test concept, the bias of voltage magnitude and phase angle errors versus the parameters uncertainty are shown for a PMU placement. Then, for different PMU placements, the values of parameters uncertainty that the state estimator is less biased are shown. The novelty of this analysis is that it finds the location of PMUs to have the state estimator less biased, considering different network parameters uncertainties.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"128 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131706066","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PMU placement for HVDC connected network considering united and islanded conditions","authors":"M. Dalali, H. Kazemi Kargar","doi":"10.1109/PSPC.2015.7094923","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094923","url":null,"abstract":"PMUs play an essential rule in monitoring and control of power network. However, it is not possible to install PMUs at all buses of network, due to economical and technical constrains. Therefore, optimal PMU placement (OPP) is done to obtain full observability of network with minimum number of PMUs and maximum redundancy. On the other hand, presence of HVDC links in power network and operating in islanded condition impose new constraints on OPP problem. Therefore, OPP considering all of mentioned goals is presented in this paper. Binary integer linear programming (BILP) is used as solver algorithm, due to linear and binary characteristics of problem. OPP is tested on IEEE 14-bus test system and different contingencies consist of single PMU failure, single line outage and occurrence of simultaneous events are studied and presented in the paper.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"162 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132102413","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Designing a compensating electronic circuit to enhance capacitive voltage transformer characteristics","authors":"M. Zare, A. Mirzaei, H. Askarian Abyaneh","doi":"10.1109/PSPC.2015.7094922","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094922","url":null,"abstract":"Capacitive voltage transformer (CVT) is widely used to convert high voltage signals to low voltage ones for measurement, protection and control. It has poor dynamics which can lead to maloperation of protective relays. Moreover, CVT has a non-smooth frequency response and limited band width which make it inappropriate for system harmonic measurements. This paper proposes a new method for decreasing CVT voltage distortions and correcting CVT dynamic response as well as its steady state response. An electronic circuit is designed so as to reproduce CVT transients. The final output which is the summation of CVT voltage and the designed circuit voltage has considerably low distortions and is a replica of the input voltage. The proposed method is independent of the load and the Ferroresonance Suppression Circuit (FSC) connected to the CVT. Simulation results confirm the efficiency and accuracy of the proposed method. Finally, CVT percentage error for the proposed method is compared with the dynamic compensation method.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"341 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117350176","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Raeisi, Mohammad Mahdi Hosseini-Biyouki, Hossein Askarian‐Abyaneh, Sabah Danyar
{"title":"Implementation of a high speed cumulative determinant-based fault detection algorithm for power system relaying","authors":"A. Raeisi, Mohammad Mahdi Hosseini-Biyouki, Hossein Askarian‐Abyaneh, Sabah Danyar","doi":"10.1109/PSPC.2015.7094931","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094931","url":null,"abstract":"A high speed cumulative determinant-based fault detection algorithm is presented in this paper. The proposed algorithm is proven to be faster and more reliable than other conventional sample-based methods such as sample to sample, cycle to cycle and cumulative sum based algorithms especially for high impedance faults. In the developed methodology, the impact of important parameters such as noise, frequency deviation, current spikes and sudden load changes as well as fault detection speed are considered to evaluate the algorithm applicability. The algorithm is applied to a single line to ground (SLG) fault in a simple two source model as well as a SLG in MANESHT to ESLAMABAD-E-GHARB 230kV power transmission line of Iran national grid as a real case.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125810091","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Active fault current limiter and comparison of its performance with SFCL","authors":"Morteza Zafari, E. Gholipour, S. M. Madani","doi":"10.1109/PSPC.2015.7094925","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094925","url":null,"abstract":"In this paper, a new approach for controlling the Static Synchronous Series Compensator (SSSC) during the fault condition is proposed. To limit the flow of large line currents, and therefore protect the SSSC and other system components, a fault limiting function is exploited in the SSSC operation.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134572436","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mohsen Tajdinian, Mehdi Zareian Jahromi, Mojtaba Jalalpour, Shahram Montaser Kouhsari
{"title":"Comprehensive and innovative method for dynamic phasor and frequency estimation","authors":"Mohsen Tajdinian, Mehdi Zareian Jahromi, Mojtaba Jalalpour, Shahram Montaser Kouhsari","doi":"10.1109/PSPC.2015.7094927","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094927","url":null,"abstract":"During the incidence of major disturbances in a large interconnected power network, frequency deviates from its nominal value. This deviation affects the estimated parameters of the phasor. This is especially very important during fault in transmission lines and generator terminals, because under fault conditions, the exponentially decaying dc component appears in current and voltage signals. An innovative hybrid method for dynamic phasor and frequency estimation is represented in this paper. Fundamental mathematics of the proposed algorithm is based on utilizing Taylor series and Nonlinear Least Squares. To increase the effectiveness of the phasor and frequency estimation, the least square method is improved. Algorithm performance has been investigated by using signals which are generated in MATLAB and PSCAD/EMTDC software. Evaluation results demonstrate that algorithm is faster and more accurate than present methods in pursuing the signal variations. This characteristic is significant, especially in fault event. In addition, simple calculations and low-latency in estimation are the other advantages of this method. This feature makes the proposed method a good performance in Real-time simulation of power systems.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126777940","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new hybrid islanding detection method combination of NJSMS and Q-f for islanding detection of microgrids","authors":"F. Namdari, Mahsa Parvizi, E. Rokrok","doi":"10.1109/PSPC.2015.7094921","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094921","url":null,"abstract":"Microgrids can provide economic and environmental benefits, but their performance poses great technical challenges in control, protection and energy management. Microgrids can be operated either grid-connected or islanded mode. Such dual configuration capability produces challenges on the design of the protection system. Fault current magnitudes will change depending on the microgrid operating mode. this paper proposes a novel hybrid method for islanding detection of microgrids. The proposed method which is a combination of nonlinear jumping Slip mode frequency shift (NJSMS) and reactive power versus frequency (Q-f) as active methods, detects the islanding phenomena by forcing the DG lose its stable operation and drift the frequency out of the normal range of the system frequency. A simple passive islanding detection scheme that relies on system frequency such as under/over frequency protection (UFP/OFP) would be sufficient to detect the moment of islanding. The effectiveness of proposed method is demonstrated and discussed through a comprehensive set of simulation studies conducted in the Matlab/Simulink environment.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132347041","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A novel static external network equivalencing method for protection studies on Iran Transmission Grid","authors":"M. Khodadadi, M. Khalilifar, S. Shahrtash","doi":"10.1109/PSPC.2015.7094928","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094928","url":null,"abstract":"In this paper, a novel static external network reduction appropriate for fault studies and relay coordination in transmission system is proposed. By applying the proposed method to IEEE 14-bus network and Hormozgan Transmission Network, its major advantages, simplicity and accuracy (less than 5% error) have been confirmed in comparison with accurate classic and approximate engineering methods. Conforming to the information structure of Iran Transmission Grid and being practical distinct the proposed method from all other accurate classic methods.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122796055","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Yousefi, Aydin Zaboli, Mohammad Mahdi Hosseini-Biyouki, Hossein Askarian‐Abyaneh, S. H. Hosseinian
{"title":"Design of a new structure for hybrid filters to eliminate harmonics of 25 kV AC electric railways","authors":"S. Yousefi, Aydin Zaboli, Mohammad Mahdi Hosseini-Biyouki, Hossein Askarian‐Abyaneh, S. H. Hosseinian","doi":"10.1109/PSPC.2015.7094930","DOIUrl":"https://doi.org/10.1109/PSPC.2015.7094930","url":null,"abstract":"In electric railways, thyristor rectifiers are used in order to control the speed. As a consequence in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Hybrid filters have several different structures. Since electric railway has a non-linear and variable nature, a novel hybrid filter structure is designed that compensates reactive power and eliminates harmonics to attain desired harmonic level regarding the conventional allowable harmonics level standards. The designed filter model is simulated in MATLAB/SIMULINK and then applied to a harmonic model of an electric railway.","PeriodicalId":368014,"journal":{"name":"The 9th Power Systems Protection and Control Conference (PSPC2015)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126812395","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}