Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference最新文献

筛选
英文 中文
Comparison of several methods for calculating power line electromagnetic interference levels and calibration with long term data 电力线电磁干扰电平的几种计算方法及长期数据校准方法的比较
R. Olsen, S.D. Schenuum, V. Chartier
{"title":"Comparison of several methods for calculating power line electromagnetic interference levels and calibration with long term data","authors":"R. Olsen, S.D. Schenuum, V. Chartier","doi":"10.1109/TDC.1991.169590","DOIUrl":"https://doi.org/10.1109/TDC.1991.169590","url":null,"abstract":"Five different methods for predicting foul weather electromagnetic interference from power overhead lines have been studied. Differences between the predictions in excess of 10 dB are common. Each method has been optimized by adding a constant chosen to minimize the difference between predictions and a set of long term measurements. The rationale for doing this is that each generation function was developed under somewhat different weather conditions. The best optimized method is the one with the smallest difference. The best methods have respectively 1.7 and 4.4 dB RMS differences between average stable foul and average fair weather measurements.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"2011 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129635256","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Utilization of polymer enclosed intermediate class arresters to improve the performance of modern power systems 利用聚合物封闭中间级避雷器提高现代电力系统的性能
D.W. Lenk, J. Koepfinger, J.D. Sakich
{"title":"Utilization of polymer enclosed intermediate class arresters to improve the performance of modern power systems","authors":"D.W. Lenk, J. Koepfinger, J.D. Sakich","doi":"10.1109/TDC.1991.169541","DOIUrl":"https://doi.org/10.1109/TDC.1991.169541","url":null,"abstract":"The first commercially available polymer enclosed intermediate class metal oxide surge arrester is introduced. The unique construction of the design is described, including reduced size, increased flexibility, a collared seal on the polymer housing and an open webbed fiberglass-epoxy module which houses the metal oxide disc elements. Performance advantages are discussed. These include improved short term contamination performance of the insulator-like polymer design when compared to multi-unit porcelain housed designs. Data show that polymer housed open-webbed fiberglass module construction extends the pressure relief capability beyond that of typical porcelain enclosed designs. The capability of the polymer enclosed design to withstand repeated pressure relief tests, simulating system reclose on a failed arrester, is also discussed. The circumstances at one utility which has considered utilizing polymer enclosed intermediate class arresters to effectively upgrade their system protection capabilities are discussed. Some suggested changes to the current ANSI C62.11 standard relative to testing polymer enclosed intermediate class arresters are addressed.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121099193","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
The Brazilian Power System and the challenge of the Amazon transmission 巴西电力系统与亚马逊输电的挑战
J. Alqueres, J. Praca
{"title":"The Brazilian Power System and the challenge of the Amazon transmission","authors":"J. Alqueres, J. Praca","doi":"10.1109/TDC.1991.169526","DOIUrl":"https://doi.org/10.1109/TDC.1991.169526","url":null,"abstract":"The Brazilian energy resources to be exploited in the near future are located in the Northern region (Amazon basin), where there is a great hydroelectric potential. Major power markets on the other hand are expected to be in the southeastern and northeastern regions. The distances between these Amazon hydro power plants and the load centers range from 2000 to 2800 km. Therefore, a great challenge will have to be faced in the future, namely the transmission of large amounts of energy from very remote sources. The main aspects of the Brazilian Power System and the factors which are being taken into consideration in the definition of the main characteristics of these transmission lines are presented.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"707 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116107559","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 51
Separable insulated connector loadbreak testing. I. The switching characteristic and its implications 可分离绝缘连接器负载断裂试验。1 .开关特性及其含义
R. Filter, J. Mintz, D. Cherney
{"title":"Separable insulated connector loadbreak testing. I. The switching characteristic and its implications","authors":"R. Filter, J. Mintz, D. Cherney","doi":"10.1109/TDC.1991.169487","DOIUrl":"https://doi.org/10.1109/TDC.1991.169487","url":null,"abstract":"Separable insulated connector switching reliability has become a concern for some utilities, particularly at higher distribution voltages. To facilitate assessments of in-service switching reliability, a second generation switching characteristic has been developed for use during laboratory loadbreak tests. This new switching characteristic is one step towards a realistic reliability assessment of separable connector switching. First generation switching characteristics are compared to the newly developed characteristic to demonstrate that the latter stresses separable connectors more realistically. A laboratory test protocol using the switching characteristic is proposed.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"90 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121584071","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Development of prefabricated type straight through joint for 275 kV XLPE cable 为 275 kV XLPE 电缆开发预制型直通接头
T. Tanaka, Y. Sekii, H. Satoh, M. Yamaguchi
{"title":"Development of prefabricated type straight through joint for 275 kV XLPE cable","authors":"T. Tanaka, Y. Sekii, H. Satoh, M. Yamaguchi","doi":"10.1109/TDC.1991.169514","DOIUrl":"https://doi.org/10.1109/TDC.1991.169514","url":null,"abstract":"The research involved in developing a prefabricated-type straight-through joint for 275 kV cross-linked polyethylene (XLPE) cable is described. Based on a review of the results of electric field analysis, a compact insulation structure using a molded epoxy insulation unit and a molded ethylene propylene rubber (EPR) stress-relieving cone was designed. The AC and lightning impulse voltage test as well as the short-circuit test and the offset test were conducted on the joint developed. The results have shown that the joint possesses excellent assembly properties and superb insulation performance. The accelerated long-term aging test was also conducted for six months and provided verification that the joint developed has adequate long-term reliability.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131395861","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Research facility for the study of power system magnetic fields 研究电力系统磁场的研究设施
L. Zaffanella, G. Rauch, G. Johnson
{"title":"Research facility for the study of power system magnetic fields","authors":"L. Zaffanella, G. Rauch, G. Johnson","doi":"10.1109/TDC.1991.169589","DOIUrl":"https://doi.org/10.1109/TDC.1991.169589","url":null,"abstract":"A magnetic field research facility was constructed at EPRI's High Voltage Transmission Research Center (HVTRC) for the purpose of reproducing power system magnetic fields under controlled conditions. The facility includes a 1200' overhead distribution line that can be configured in different ways and a water distribution system that can be connected in different ways to the neutral wires. The distribution line serves a two-storey test residence and 18 other residences simulated by load cabinets. The electrical connections, grounding, electrical wiring and appliances of the test residences were designed to study the effect of source parameters on residential magnetic fields. Examples of measurements and applications of this facility are given.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115780531","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
An automated fault locating system 自动故障定位系统
J. Steiner, W. Weeks, H. W. Ng
{"title":"An automated fault locating system","authors":"J. Steiner, W. Weeks, H. W. Ng","doi":"10.1109/TDC.1991.169511","DOIUrl":"https://doi.org/10.1109/TDC.1991.169511","url":null,"abstract":"A prototype system for automatically locating faults is described and all of the measurements are interpreted by computer. The instrument implements a three step procedure for locating the fault. A global procedure is used to locate the fault to the nearest transformer. Precision methods are then used to localize and then pinpoint the fault. The general theory necessary for the implementation of the system is developed.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125596274","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
A computerized numerical database on electrical insulating materials for power transmission and distribution applications 输配电用电绝缘材料的计算机数字数据库
G. Marinescu, H.H. Li, C.Y. Ho, N. Singh
{"title":"A computerized numerical database on electrical insulating materials for power transmission and distribution applications","authors":"G. Marinescu, H.H. Li, C.Y. Ho, N. Singh","doi":"10.1109/TDC.1991.169508","DOIUrl":"https://doi.org/10.1109/TDC.1991.169508","url":null,"abstract":"A computerized numerical database on electrical, thermal, mechanical, degradation and other properties of electrical insulating materials for overhead and underground electric power transmission and distribution has been developed. The database is continuously updated and upgraded following new developments in insulating materials for transmission and distribution systems. As a central source of technical and applications data on electrical insulating materials directly accessible online, this database is a valuable tool in developing, designing, and manufacturing insulating systems for electric utility equipment. The database is interactive, menu-driven, and user-friendly. It permits the direct mode of search/retrieval of data for specified materials, properties, and independent variables, and the inverted mode of search/retrieval of qualified materials that meet a set of specified property requirements (which is the computer-aided materials selection). It also enables units conversion, variable transformation, and interactive graphical display and manipulation of the retrieved data. The methodology for data compilation, evaluation, analysis, and correlation and the database development, content, and operation are presented and discussed.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125128459","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Considerations for higher voltage distribution 高压配电的注意事项
A. Jones, B.E. Smith, D. Ward
{"title":"Considerations for higher voltage distribution","authors":"A. Jones, B.E. Smith, D. Ward","doi":"10.1109/TDC.1991.169577","DOIUrl":"https://doi.org/10.1109/TDC.1991.169577","url":null,"abstract":"The proper selection of a distribution voltage is one of the more important considerations of the electric utility planning engineer. This determination can have a significant effect on the economics and efficiency of transmission and distribution power delivery. The major considerations involving the selection of the voltage level for distribution facilities, principally 25 kV and 35 kV systems, are discussed, and experience with 34.5 kV is highlighted.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134487858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Failure mode testing of underground polymer surge arresters 地下聚合物避雷器失效模式试验
H.G. Yaworski
{"title":"Failure mode testing of underground polymer surge arresters","authors":"H.G. Yaworski","doi":"10.1109/TDC.1991.169540","DOIUrl":"https://doi.org/10.1109/TDC.1991.169540","url":null,"abstract":"Underground metal oxide surge arresters are being used in increasing numbers to protect underground distribution cable and equipment. Laboratory failure mode tests and field experience have shown that current UD surge arrester designs fail in a manner which may not provide adequate safety for nearby operating personnel. The mode of failure of these arresters is described, and a design that limits the outcome of violent failures through controlled energy release is proposed.<<ETX>>","PeriodicalId":367010,"journal":{"name":"Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132149656","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书