{"title":"Development of a tethered epicardial crawler for minimally invasive cardiac therapies","authors":"N. Patronik, M. Zenati, C. Riviere","doi":"10.1109/NEBC.2004.1300083","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1300083","url":null,"abstract":"This paper describes the development of a robotic surgical device to facilitate minimally invasive, beating-heart cardiac therapies that can be performed within the pericardium. The concept we propose is that the device be equipped with the ability to adhere to the surface of the epicardium and locomote to any position and orientation under the direct control of a physician. As compared to current minimally invasive cardiac robotics, our approach obviates cardiac stabilization, lung deflation, differential lung ventilation, and reinsertion of laparoscopic tools. These advantages will result in greater efficiency and reduced trauma for the administration of intrapericardial therapies. This paper describes the current design of the robotic device and presents preliminary results.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117027565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The effects of drugs on Pluronic F127 structure","authors":"P. K. Sharma, S. Bhatia","doi":"10.1109/NEBC.2004.1300078","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1300078","url":null,"abstract":"Small-angle neutron scattering was used to study the effects of several drugs and additives on the aggregation number, core and corona radii and interparticle interaction distance of Pluronic F127 micelles. Depending upon their molecular weight and partition coefficient, these drugs were found to cause changes in the micellar structure. Our findings have implications on the performance and design of F127 drug delivery formulations.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"161 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127317562","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electrode chemistry of prolonged external pacing","authors":"P. F. Meyer, P. Gadsby","doi":"10.1109/NEBC.2004.1299979","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1299979","url":null,"abstract":"Prolonged external cardiac pacing can produce electrochemical skin burns associated with the production of OH/sup -/, and eventually H/sup +/, through hydrolysis. This study compares the performance of a new multifunction defibrillation/pacing/ECG electrode design to that of other commercially available electrodes during sustained pacing. Pacing voltage changes and pH measurements predict the eventual depletion of electrode constituents and the onset of hydrolysis. The results indicate that the new electrode delays the rise of electrode offset voltage and resulting pH increases compared to several competing electrode designs.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"33 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116386356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Spinning of collagen fibers and characterizing thermal, mechanical, tensile and structural properties","authors":"G. Tatagiri, G. Collins, M. Jaffe","doi":"10.1109/NEBC.2004.1300031","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1300031","url":null,"abstract":"This study focuses on the wet spinning of collagen fibers using dispersions made from bovine tendon, and to the modification of the resulting fiber properties by cross-linking the collagen with gluteraldehyde. The fibers are characterized for mechanical properties, effect of temperature on dimension changes, temperature dependent heat flow, and temperature dependent weight loss. The above tests are conducted using TMA, DSC and TGA.The fiber diameters and surface features are studied using SEM. The results of these analyses are compared with cross-linking and without cross-linking for each of the three dispersion percentages, 1%, 1.6% and 2%. The mechanical behavior of cross linked collagen fibers was enhanced relative to the non cross linked fibers with higher denaturation temperature and lower tensile deformation.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128292482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A neural network based method for the inverse problem of electrical impedance tomography","authors":"S. Acharya, B. C. Taylor","doi":"10.1109/NEBC.2004.1299990","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1299990","url":null,"abstract":"Electrical impedance tomography is an emerging imaging modality based on reconstruction of the resistivity distribution of the interior of the body, using non-invasive surface electrical measurements. Image reconstruction is a nonlinear, ill-posed, inverse problem. A new approach to the reconstruction problem is proposed, using multi-layer feed forward neural networks. The technique was tested using numerical simulations and actual measurements from a physical model. When compared with iterative techniques, superior performance was observed vis-a-vis image quality, reconstruction time and robustness to noise. This method can be easily adapted for different forward models of resistivity distribution used in existing reconstruction algorithms.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128603453","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fatigue of human cortical bone under axial-torsional loading","authors":"W. T. George, D. Vashishth","doi":"10.1109/NEBC.2004.1300039","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1300039","url":null,"abstract":"Since bone mass based measurements have demonstrated limited success in predicting age-related increase in fracture incidence, recent emphasis has been placed on quantification of bone quality. The current study reports the multiaxial failure characteristic of bone (quality) by conducting fatigue tests on human cortical bone specimens under physiologically relevant axial-torsional loading. Our results show for the first time that, compared to uniaxial tests, multiaxial fatigue tests show a four-fold reduction in the fatigue life of human cortical bone. Furthermore, the weak mode in physiologically relevant axial-torsional loading changes with age. Bones in the older group (> 50 yrs) were weaker in torsional than in axial loading and the bones in the younger donor group (< 50 yrs) were weaker in axial than torsional loading (p < 0.05).","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130396462","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of tissue factor on plasma and packed RBC clotting parameters","authors":"D. Patel, J. Davidson, D. Kristol, C. Spillert","doi":"10.1109/NEBC.2004.1300089","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1300089","url":null,"abstract":"Tissue factor (TF) is a transmembrane glycoprotein and the main triggering element for blood coagulation. Expression of TF on the cell surfaces and its appearance as a soluble molecule are characteristic features of acute and chronic inflammation in conditions such as arteriosclerosis leading to stroke and myocardial infection. A study was performed on human citrated whole blood, by separating plasma from the red blood cells. Ten microlitres of 25% tissue factor (TF) was added to both the plasma and packed red blood cells (RBC's), and the clotting time, rate of clot formation and the maximum strength of the clot determined. TF bearing samples clotted more rapidly and had greater clot strength when compared to that of control aliquots.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114763709","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement of acoustic properties of breast tissue phantoms using ultrasound","authors":"L. McLeod, P. Griffin, D. Muratore","doi":"10.1109/NEBC.2004.1299987","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1299987","url":null,"abstract":"Breast tissue phantoms will be created in order to measure their acoustic properties using ultrasound (US). This study could potentially further the development of US as a supplement or alternative to breast cancer screening techniques.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124095995","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ultrasound image enhancement based on an annular array pulse-echo system","authors":"P. Pedersen, A. Nadkami","doi":"10.1109/NEBC.2004.1299989","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1299989","url":null,"abstract":"An important aspect of diagnostic ultrasound is a good visualization of organ or tissue surfaces. The goal of the ultrasound image enhancement method presented in this paper is to selectively enhance the clarity of anatomical structures of a specified geometry, such as arteries. With ultrasound array transducers, e.g. linear and annular arrays, a large number of different insonifying ultrasound fields can be produced, including ultrasound fields which will maximize the energy of the received signal for a given transducer and reflector geometry. The calculation of such fields is described in this paper.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"s3-19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130083165","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Carbon nanofibers:polycarbonate urethane composites as a neural biomaterial","authors":"D. Khang, J. McKenzie, T. Webster","doi":"10.1109/NEBC.2004.1300084","DOIUrl":"https://doi.org/10.1109/NEBC.2004.1300084","url":null,"abstract":"Chronic neural implants are usually made from silicon materials and are subject to scar tissue formation at the tissue/implant interface, which interferes with their functionality. Carbon nanofibers are an example of a material that may improve neural implant interactions with native cell populations since these nanofibers have promising cytocompatibility, mechanical, and electrical properties. Neural implants may achieve better tissue interactions simply by incorporating carbon nanofibers into a polymer matrix. Polycarbonate urethane and carbon nanofiber composites have induced neurite extension during in vitro studies. The objective of the present study was to use an electrical field to align carbon nanofibers in a polycarbonate urethane matrix. Polycarbonate urethane was dissolved in chloroform, and then mixed with carbon nanofibers of high and low surface energies separately. When the solution was viscous, it was pored into a parallel copper plate capacitor chamber. Alignment occurred after exposure to 500 to 700 volts. The aligned nanofiber structure was maintained after the polymer cured. These materials have been prepared to determine if neuron axonal extension will be affected by the carbon nanofiber alignment. These materials have promising tunable properties for neural implants such as electrical, nanoscale structure and organization, and surface energy characteristics.","PeriodicalId":362628,"journal":{"name":"IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the","volume":"80 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134017870","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}