W. Cao, Z. Tan, Ying Xie, B. Zahawi, A. Smith, M. Jovanović
{"title":"Analysis of wind power data for optimising DFIGs","authors":"W. Cao, Z. Tan, Ying Xie, B. Zahawi, A. Smith, M. Jovanović","doi":"10.1109/EFEA.2012.6294039","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294039","url":null,"abstract":"This paper evaluates various wind power estimation models to represent the wind energy for machine design and control purposes. Traditionally, linear, quadratic and cubic formulas have been used for interpolating wind power curves but have their limitations. Due to the fluctuating nature of wind power, they may not be accurate to model the actual wind speed profile and nor convenient for wind turbine generator design and control which demands a representative site-specific wind speed profile. On the basis of the DFIG equivalent circuit, loss components and maximum efficiency of DFIGs are derived and these are taken into account when optimising DFIGs to match the specific site of development.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125709797","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An analytical model for frequency analysis of composite wind turbine blades","authors":"Hui Zhang, A. Maheri, A. Daadbin, P. Hackney","doi":"10.1109/EFEA.2012.6294044","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294044","url":null,"abstract":"This paper presents an analytical model for predicting the dynamic characteristics of composite wind turbine blades. In this model, the governing equations of motion are derived using Hamiltion's principle and are solved by using extended Galerkin's method. This model is capable of predicting natural frequencies of composite beams with arbitrary single-cell cross sections. For various layup configurations, the results obtained by the developed analytical model are compared with the results of the finite element analysis. It is shown that the analytical model provides reasonable accuracy in predicting natural frequency of unbalanced layup configurations with ply angles of up to 40 degrees.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134541200","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
L. Baghli, A. Moussaoui, K. Benmansour, S. Delprat, M. Djemai
{"title":"Optimal hybrid vehicle, embedded data acquisition and tracking","authors":"L. Baghli, A. Moussaoui, K. Benmansour, S. Delprat, M. Djemai","doi":"10.1109/EFEA.2012.6294082","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294082","url":null,"abstract":"The paper is about the first part of a PNR (National Research Program). The study is divided into numerous parts. The first one concerns the collect of operating points of a conventional (engine) vehicle to know the energy consumption and instantaneous power needed on a driving path, in a suburban and urban everyday use of the vehicle. This paper presents the hybrid, electrical and conventional vehicle technology followed by the first part of the PNR study. It shows how the acquisition system is build, based on OBD-II CAN interface. PIDs and GPS data are recorded and displayed using 2D and 3D maps and tables. The preliminary results are presented and commented.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133043545","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A transparent solar patch antenna for 2.4/2.5 GHz WLAN-WiMAX applications","authors":"O. Yurduseven, D. Smith, N. Pearsall, I. Forbes","doi":"10.1109/EFEA.2012.6402418","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6402418","url":null,"abstract":"This paper reports a green transparent patch antenna combined with a polycrystalline silicon solar cell capable of generating DC power with a zero carbon footprint whilst receiving and transmitting microwave signals. The obtained results introduce a further potential of solar cells being used as embedded elements within WLAN/WiMAX communication systems. The multifunctionality of solar cells against fossil fuels, which play a key role in global warming, is demonstrated to make solar cells the primary choice to meet the energy demands of our daily lives in an environmental-friendly way.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117289277","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Application of The calculated PWM technique in the photovoltaic pumping system","authors":"M. Chergui, M. Bourahla, A. Aissaoui","doi":"10.1109/EFEA.2012.6294052","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294052","url":null,"abstract":"This paper aims to reach at an improved control and optimization between the different functions of the elements of a solar pumping system. The solar panel can supply maximum power only for defined output voltage. The operation to get the maximum power depends on the terminals of load, mostly a non-linear load like induction motor. That is why we have given in this work two different solutions for two problems. Firstly, we used an intelligent control method for the tracking module inserted in the photovoltaic system under variable temperature and irradiance conditions. The tracking module can be used to maintain the operation of the photovoltaic panel at maximum power by controlling the voltage or current generator independently of the load. Secondly, ours pumping system was tested with the calculated pulse wide modulation technique inverter to order to reduce the noise, oscillations of the torque and current, also the disturbance on speed.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116788319","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Khaled, J. Barbot, D. Benmerzouk, Krishna Busawon, M. Ghanes
{"title":"Strange attractor identification and state observation under sparse measurements","authors":"Y. Khaled, J. Barbot, D. Benmerzouk, Krishna Busawon, M. Ghanes","doi":"10.1109/EFEA.2012.6294061","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294061","url":null,"abstract":"In this paper, a new method of strange attractor identification, under sparse measurement, is proposed this method is based on the concept of compressive sensing. For this, some particular impulsive observers have been presented and adding a decision scheme linked to diagnosis method, the identification of the strange attractor and state observation are done. Some simulations results are given in order to highlight the well founded of the proposed design.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115513994","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Traffic velocity control for evaluation the impact of gases emissions: Case study of toll plaza","authors":"Uzunova M, Losero R, Lauber J, Djemai M","doi":"10.1109/EFEA.2012.6294087","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294087","url":null,"abstract":"The purpose in this paper is to evaluate the impact of CO2 emissions from traffic in interurban area. Initially the main idea was to apply control strategy on the road under the assumption to assure fluid traffic flow. In the following the gases emissions was evaluated as results of this regulation procedure. The proposed control approach is based on noninteger robust methodology. Therefore, is possible to analyse the speed and density variations due to perturbations on the road and to assure robust performances for the traffic velocity. The pollution factor of CO2 emissions of the controlled and uncontrolled model was evaluated and compared. The chosen study case is macroscopic traffic flow model, situated downstream on a toll plaza. The method of modelling traffic flow at macroscopic level is based on the assumption that the whole traffic stream is comparable to fluid stream. The motion law of vehicle and his full fuel combustion equation are presented. Then the models of the traffic with the CO2 emissions, for all the traffic streams, were combined. The control of the traffic situated downstream on a toll plaza scenario has been designed. Based on simulations, the robust performances of the parameter variations and their influences on the CO2 emissions were evaluated.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121725978","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Stabilization by New control technique of the input DC voltages of five-level diode - Clamped inverters. Application to double star induction machine","authors":"Z. Oudjebour, E. Berkouk, M. Mahmoudi","doi":"10.1109/EFEA.2012.6294034","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294034","url":null,"abstract":"This paper presents the stabilization of the input DC voltages of five-level diode-clamped (FLDC) voltage source inverters (VSI). We propose a cascade circuit consisting of a FLDC rectifier a FLDC VSI. First, the different cascade parts and their control strategies are presented. The stability problem of the input DC voltages of the inverter is investigated. To remedy to this problem, two solutions are proposed: the first one uses the linear feedback control algorithm and the second one uses the non-linear control by the Lyapunov technique at the FLDC rectifiers. As an application, the performances of the double star induction machine (DSIM), as fed by the cascade, are observed. The obtained results are full of promise concerning the use of multilevel diode clamped inverters in high voltage/high power applications such as electrical traction.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127498141","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Control active and reactive power of Voltage Source Inverter (VSI)","authors":"H. Vu, H. Yahoui, T. Chorot, H. Hammouri","doi":"10.1109/EFEA.2012.6294057","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294057","url":null,"abstract":"This paper introduces the reactive and active power control of Voltage Source Inverter (VSI). A decoupled control scheme has been implemented basing on the current at the terminal of the VSI. The introduced power control can be effectively applied to renewable energy systems in regulation of the power factor to improve the voltage stability and power quality for connected electric power system. Simulation in the environment of Matlab-Simulink is developed to verify the capability of power control as well as power factor control.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"240 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115754014","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A comparative study of the performance of DC permanent magnet and AC induction motors in urban electric cars","authors":"Kanber Sedef, A. Maheri, A. Daadbin, M. Yilmaz","doi":"10.1109/EFEA.2012.6294077","DOIUrl":"https://doi.org/10.1109/EFEA.2012.6294077","url":null,"abstract":"This paper presents a comparative study of the performance of two types of electric motors used in eco-urban electric cars (EC). The power transmission system of an EC is modelled once with a DC permanent magnet (PM) and once with an AC induction motor (IM). In both cases the electric motors can operate in two modes: propulsion mode (motor) and regenerative brake mode (generator). Two standard velocity history profiles SFUDS and ECE-15 are used to model the dynamic of the car. It is shown that IM performs more effective than PM.","PeriodicalId":361253,"journal":{"name":"2012 2nd International Symposium On Environment Friendly Energies And Applications","volume":"85 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123567313","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}