{"title":"EMC Installation for Variable Speed Drive Systems (VSDs)","authors":"S. Nadweh, Zeina A. Barakat, G. Hayek","doi":"10.4018/978-1-5225-8030-0.CH013","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH013","url":null,"abstract":"This chapter introduces EMC installation for variable speed drive systems. As an introduction, EMC standards have been mentioned in order to define the requirements characteristics, besides the fundamentals of static, electric, magnetic, and electromagnetic fields. Both inductive and capacitive coupling have been discussed to deal with shielding. Finally, VSDS emission and electromagnetic interferences were studied with installation requirement in VSDS (supply cables, cable between converter and motor, control cables, earthing requirements, and grounding).","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131858101","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Feras Mahfoud, B. D. Guzun, G. Lazaroiu, Hassan Haes Alhelou
{"title":"Power Quality of Electrical Power Systems","authors":"Feras Mahfoud, B. D. Guzun, G. Lazaroiu, Hassan Haes Alhelou","doi":"10.4018/978-1-5225-8030-0.CH011","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH011","url":null,"abstract":"Power quality problems can cause processes and equipment to malfunction or shut down. And the consequences can range from excessive energy costs to complete work stoppage. Obviously, power quality is critical. There are many ways in which a power feed can be poor quality, and so no single figure can completely quantify the quality of a power feed. In this chapter, the authors present all definitions, classifications, and problems related to power quality. Finally, they do a comparison between the practical measurements and standards related to power quality.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127118310","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Enrichment of Distribution System Stability Through Artificial Bee Colony Algorithm and Artificial Neural Network","authors":"G. S. Rao, Y. Obulesh, B. Rao","doi":"10.4018/978-1-5225-8030-0.CH002","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH002","url":null,"abstract":"In this chapter, an amalgamation of artificial bee colony (ABC) algorithm and artificial neural network (ANN) approach is recommended for optimizing the location and capacity of distribution generations (DGs) in distribution network. The best doable place in the network has been approximated using ABC algorithm by means of the voltage deviation, power loss, and real power deviation of load buses and the DG capacity is approximated by using ANN. In this, single DG and two DGs have been considered for calculation of doable place in the network and capacity of the DGs to progress the voltage stability and reduce the power loss of the system. The power flow of the system is analyzed using iterative method (The Newton-Raphson load flow study) from which the bus voltages, active power, reactive power, power loss, and voltage deviations of the system have been achieved. The proposed method is tested in MATLAB, and the results are compared with particle swarm optimization (PSO) algorithm, ANN, and hybrid PSO and ANN methods for effectiveness of the proposed system.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116903376","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Synchrophasor-Based Wide Area Protection Scheme for System Stressed Conditions to Avoid Power System Blackout","authors":"Kasimala Venkatanagaraju, M. Biswal","doi":"10.4018/978-1-5225-8030-0.CH001","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH001","url":null,"abstract":"Protection of transmission system is crucial for the secured and stable operation of power system. Under stress conditions, the operating parameters of power system violate their limits. From the past anatomy reports of several blackouts, it is clear that equipment, control, and protective relay failures are the major causes behind large power system failure. From study, it is also revealed that failure of back-up protection is more prone during system stressed conditions. In transmission system, third-zone of distance relay is highly affected by system stressed events such as voltage instability and load encroachment. As third-zone protection is a delayed protection scheme, with the help of wide area measurement system better protection function can be provided to reduce future percentage of blackout. In this chapter, a detailed discussion about the existing solutions is provided to mitigate the issue of system stressed conditions and a synchrophasor technology-based approach is provided. Results for different cases are provided to show the efficacy of the proposed method.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122167288","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transition From Traditional Grid to Smart One","authors":"Haitham Daghrour, Razan Mohammad Al-Rhia","doi":"10.4018/978-1-5225-8030-0.CH008","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH008","url":null,"abstract":"Smart grids have become an urgent need to overcome the challenges of the 21st century. To transit the traditional grid to smart one, there must be a well thought out plan, called road map, which is also being carefully developed by organizations according to standards for deploying smart networks. Most studies focused on modernizing distribution networks because it was passive and technologically poor. Two approaches to developing distribution networks were presented. The smart grid modernization was also presented from social and psychological perspectives.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115222865","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Issues Associated With Microgrid Integration","authors":"B. Khan, S. Tanwar","doi":"10.4018/978-1-5225-8030-0.CH010","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH010","url":null,"abstract":"Microgrid (MG) is the vital technology that can be utilized to supply electricity to rural areas by fulfilling various aspects of electricity such as sustainability and reliability. Further, MG technology can also be used as localized generation sources and back up supply source. As MG can be worked in interconnected mode, various issues related to interconnection with utility grid are raised. Several issues such as technical, regulatory, and operational are associated with grid integration. Therefore, this chapter deals with the issues that are associated with the grid integration of microgrid.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"144 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115679792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dynamic and Stability Analysis of Wind-Diesel-Generator System With Intelligent Computation Algorithm","authors":"Dipayan Guha, P. Roy, Subrata Banerjee","doi":"10.4018/978-1-5225-8030-0.CH003","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH003","url":null,"abstract":"In this chapter, the dynamic performance of a wind-diesel-generator system has been studied against wind and load perturbations. The wind perturbation is modeled by simulating base, ramp, gust, and random wind. An optimized cascade tilt-integral-derivative (CC-TID) controller is provided to the test system for producing desired control signal to regulate the blade pitch angle of wind turbine. To confirm the efficacy of CC-TID controller, the output results are compared to that of PI- and PID-controller. The optimum gains of the proposed controllers are explored employing Levy-embedded grey wolf optimization, whale optimization algorithm, drone squadron optimization, and search group algorithm. To show the effectiveness, the output results are compared to the results of genetic algorithm and particle swarm optimization tuned controllers. A thyristor control series compensator (TCSC) is provided to WDG model for increasing the damping of system oscillations. Analysis of the presented results confirm the supremacy of CC-TID-TCSC controller over other controllers provided in this chapter.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126606415","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Reliable Electricity Generation in RES-Based Microgrids","authors":"V. Kharchenko, V. Gusarov, V. Bolshev","doi":"10.4018/978-1-5225-8030-0.CH006","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH006","url":null,"abstract":"Using microgrid generation technologies is proposed in order to organize reliable power supply to rural areas. The concept of microgrid based on RES is considered as one of the realization forms of the distributed energy paradigm. In this chapter, there are the principles of generating complex formation in any given microgrid considering the specifics of the region, consumption patterns, and the potential of renewable energy sources in a given area. The algorithm for meeting the challenges of forming the structure of the microgrid generating structure is shown. The criteria for selection of power generation sources when solving the issue of their inclusion in the microgrid is proposed. The chapter also suggests the design of the micro gas turbine that is able to operate on biogas.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"144 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133418749","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Introduction to Smart Grid and Micro-Grid Systems","authors":"S. Nadweh, Zeina A. Barakat","doi":"10.4018/978-1-5225-8030-0.CH015","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH015","url":null,"abstract":"This chapter describes the upcoming technology for electrical power systems that gives the appropriate solution for the integration of the distributed energy resources. In this chapter, different categories of smart grids have been classified, and the advantages, weakness, and opportunities of each one, are given in addition to determining its own operating conditions. Micro-grids are the most common kind of smart grid. It has been classified under different criteria, such as architecture with different topology (connected mode, island mode, etc.) and demand criteria (simple micro grids, multi-DG, utility) and by capacity into simple micro-grid, corporate micro-grid, and independent micro-grid, and by AC/DC type to DC micro-grids, AC micro-grids, Hybrid micro-grids. Finally, most familiar Micro-grid components have been discussed such as an energy management system along with several types of control and communication systems in addition to the economic study of a micro-grids.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133685026","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Operation of Microgrid and Control Strategies","authors":"S. Veeraganti, Ramchandra Nittala","doi":"10.4018/978-1-5225-8030-0.CH019","DOIUrl":"https://doi.org/10.4018/978-1-5225-8030-0.CH019","url":null,"abstract":"Microgrids are the most innovative area in the electric power industry today. A microgrid can operate in grid-connected or islanded mode. In islanded mode, microgrids can provide electricity to the rural areas with lower cost and minimum power losses. Several methods have been proposed in the literature for the successful operation of a microgrid. This chapter presents an overview of the major challenges and their possible solutions for planning, operation, and control of islanded operation of a microgrid. Microgrids are the most innovative area in the electric power industry today. Moreover, microgrids provide local voltage and frequency regulation support and improve reliability and power capacity of the grid. The most popular among the control strategies based on droop characteristics, in addition a central controller is described within a hierarchical control scheme to optimize the operation of the microgrid during interconnected operation. Microgrid control methods, including PQ control, droop control, voltage/frequency control, and current control methods are formulated.","PeriodicalId":360968,"journal":{"name":"Handbook of Research on Smart Power System Operation and Control","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131364569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}