{"title":"Frequency control by HVDC connected offshore wind farms for overfrequency limitation","authors":"M. Suwan, I. Erlich","doi":"10.1109/ENERGYCON.2016.7514017","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7514017","url":null,"abstract":"This paper discusses the utilization options of high voltage direct current (HVDC) connected offshore wind farms (WFs) to contribute to the fast frequency control during overfrequency events. A disturbance such as a sudden loss of load in a grid will cause the frequency to increase; the first seconds in the response are shaped mainly by the total inertia level in the grid. With increasing share of inertia-less wind generation in modern grids, a fast overfrequency limiting control should be provided by the wind farms. Power reduction by pitching is the most common and straightforward method. Kinetic energy control can additionally reduce the overfrequency. An alternative strategy utilizing the HVDC chopper to limit the frequency overshoot is introduced in this paper. A test grid is used to analyze the performance of the above mentioned strategies. Significant improvements in the frequency response are achieved through combined strategies.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131104172","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ilman Sulaeman, Victor Vega-Garita, G. C. Mouli, N. Narayan, L. Ramirez-Elizondo, P. Bauer
{"title":"Comparison of PV-battery architectures for residential applications","authors":"Ilman Sulaeman, Victor Vega-Garita, G. C. Mouli, N. Narayan, L. Ramirez-Elizondo, P. Bauer","doi":"10.1109/ENERGYCON.2016.7514014","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7514014","url":null,"abstract":"The paper provides a comparison of four PV-battery architectures with dc and ac backbones, in terms of autarky, energy efficiency, battery size and reduction of annual electricity cost. The comparison is conducted based on the residential load and irradiation data from the Netherlands. The effect of different PV generation is also analyzed by comparing the results with irradiation data from Costa Rica. The results show that the ac coupled architecture gives the best performance.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134288740","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Energy Efficiency of Data Centers: A data-driven model-based approach","authors":"Baya Hadid, S. Lecoeuche, David Gille, C. Labarre","doi":"10.1109/ENERGYCON.2016.7514136","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7514136","url":null,"abstract":"Issues in Energy Efficiency of Data Centers (DC) are important, due to the cumulative effects of the increase in the DCs number and in the energy consumption per center. Developing new design recommendations to improve a cooling system efficiency, commonly quantified by the PUE metric (Power Usage Effectiveness) is one objective of the Green IT organizations. For existing DCs, without considering the optimization of the IT workload, a possible way to improve the DC's energy efficiency is to adjust the cooling setpoints. In this paper, a methodology based on predictive models is used to optimize the PUE by improving the cooling setting. The modeling approach consists in exploiting the temperatures and energy measurements at various operating conditions to predict the PUE behavior using data-driven models commonly called black box models. The optimization procedures are based on the simulation of these models in order to estimate the best working conditions.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133541438","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Klonari, J. Lobry, F. Vallée, B. Meersman, D. Bozalakov, T. Vandoorn
{"title":"Long term assessment of a voltage unbalance mitigation scheme implemented by photovoltaic inverters","authors":"V. Klonari, J. Lobry, F. Vallée, B. Meersman, D. Bozalakov, T. Vandoorn","doi":"10.1109/ENERGYCON.2016.7513898","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7513898","url":null,"abstract":"This paper applies a long term network observability analysis for investigating the potential contribution of photovoltaic (PV) inverters to the mitigation of voltage unbalance in low voltage (LV) feeders. For this purpose, a probabilistic offline state estimation algorithm is used, which simulates the time-varying action of local voltage (magnitude and unbalance) control schemes. The paper focuses on a control scheme that acts resistively towards the negative- and zero-sequence voltage components without modifying the total nodal injected power (three phase damping control scheme) For this long term evaluation, feeder- and user-specific smart metering (SM) data are used. The volatile character of PV generation and loads is modelled on a 15-min time scale. As a case study, a real LV feeder with distributed PV generation and long-term user-specific SM measurements is simulated. The three phase damping control results to be more advantageous compared with currently applied voltage control schemes.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"230 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115751300","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Omar Bottesi, L. Alberti, R. Sabariego, J. Gyselinck
{"title":"Identification of high-frequency parameters of an inset PM motor including eddy currents","authors":"Omar Bottesi, L. Alberti, R. Sabariego, J. Gyselinck","doi":"10.1109/ENERGYCON.2016.7514072","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7514072","url":null,"abstract":"This paper aims to compute the high-frequency parameters of an inset permanent magnet synchronous machine. A homogenization technique for the computation of the eddy currents and the identification of the d-q model at high-frequency of the synchronous machine are briefly recalled. The simulation strategy for the Inset PM motor is introduced. A comparison between the high-frequency parameters is highlighted considering 2D and 3D models of the machine in order to validate the homogenization technique. Different operating conditions are considered: both at no load and under load. Good agreement has been found between 2D and 3D results.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124857901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Raúl Sarrias-Mena, Luis M. Fernández‐Ramírez, C. García-Vázquez, C. E. Ugalde-Loo, N. Jenkins, F. Jurado
{"title":"Modelling and control of a medium-voltage DC distribution system with energy storage","authors":"Raúl Sarrias-Mena, Luis M. Fernández‐Ramírez, C. García-Vázquez, C. E. Ugalde-Loo, N. Jenkins, F. Jurado","doi":"10.1109/ENERGYCON.2016.7513990","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7513990","url":null,"abstract":"Electric power systems will need to accommodate large amounts of renewables and a growing number of DC loads with reduced costs and losses. Medium-voltage DC distribution lines can play a key role. Moreover, a higher availability and reliability of the power supply can be achieved with energy storage systems (ESSs). In this paper, a hybrid configuration merging both concepts is evaluated. A medium-voltage DC distribution system with an integrated ESS has been proposed, modelled, and simulated. Voltage source converters have been used for the AC/DC conversions. The ESS is connected to the DC bus through a dual active bridge enabling bidirectional power flow while covering a large voltage gap. The controllers for all converters and a supervisory control scheme have been implemented. Simulations show the capability of the hybrid configuration to fulfill variable grid demand regardless of the wind power generation, thus transforming a fluctuating source into a dispatchable supply.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134295689","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis of interactions between electricity and gas systems at European level","authors":"M. Dicorato, G. Forte, M. Trovato","doi":"10.1109/ENERGYCON.2016.7514099","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7514099","url":null,"abstract":"Installation of gas-based power plants and energy carrier availability to final users have given rise to the need of synergies in the development of networks for electricity and gas. Moreover, electrically driven gas compressor stations and power-to-gas technologies open further levels of interaction. In this context, the analysis of interaction of electric power and gas flows and the development optimization of both systems should be carried out. To this purpose, in this paper, a procedure is proposed to analyze effects of exchange limits and energy prices in gas and electricity systems at given load levels. The procedure is applied to a framework of the European system.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"407 25","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134289159","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Heuristic algorithm for minimizing the electricity cost of air conditioners on a smart grid","authors":"M. Arikiez, F. Grasso, D. Kowalski, M. Zito","doi":"10.1109/ENERGYCON.2016.7513915","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7513915","url":null,"abstract":"This paper investigates using heuristic algorithms to solve Multi-Objective Optimization Problem (MOOP). The primary goal is to minimize the electricity cost for a set of air conditioners in residential or commercial buildings. The second objective is to minimize the discomfort factor. The algorithm, also, enhances the utilization of local renewable power. This allocation problem can be formulated using a static technique such as Mixed Integer Linear Programming (MILP), but solving MILP-based MOOP could be impracticable in heavy problems due to the hardness of the problem. Accordingly, a trade-off between cost and runtime is required. Our algorithm uses an MILP-based heuristic algorithm and LP relaxation and an innovative rounding technique called, Minimum Deviation Rounding (MDR) to get a sub-optimal solution. The result reveals that our algorithm can solve a massive problem in few seconds and gives a superb sub-optimal solution.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"74 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133055599","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Kristof L. De Koker, G. Crevecoeur, B. Meersman, M. Vantorre, L. Vandevelde
{"title":"Energy storage system for off-grid testing of a Wave Energy Converter","authors":"Kristof L. De Koker, G. Crevecoeur, B. Meersman, M. Vantorre, L. Vandevelde","doi":"10.1109/ENERGYCON.2016.7514097","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7514097","url":null,"abstract":"During the development of a wave energy converter (WEC), a test device was laid out at sea. Due to the absence of a grid connection at the test location, an energy storage system (ESS) is designed and implemented as an islanding power supply to test the WEC requiring motoring actions during operation. The ESS comprises long-term battery power supply for the controllers, supercapacitors (SC) for motoring purposes in the WEC, and the supply of auxiliaries. The sizing of the system was carried out on the basis of hydrodynamic simulations of the WEC. We optimized the lifetime of the SC by reducing the voltage working range. Subsequent tests at sea revealed positive evaluation of the ESS.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133030995","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A modern laboratory test bench for power protection unit testing","authors":"A. Smolarczyk, D. Rasolomampionona","doi":"10.1109/ENERGYCON.2016.7514003","DOIUrl":"https://doi.org/10.1109/ENERGYCON.2016.7514003","url":null,"abstract":"In the submitted paper, a modern laboratory test bench for generating unit protections testing is described. Both physical construction and principle of operation are presented. The test bench is composed of: a laboratory stand with a functional front panel, one ABB REG 316*4 relay, one set of testing devices composed of Omicron™ CMC 156 testing unit and CMS 156 amplifier, one personal computer. Three configuration sets are used for the protection of generating units. Included is also the way how laboratory tests are conducted within the framework of student teaching process, using the above presented test bench. A few examples of tests results are presented in order to illustrate the operation of the laboratory stand.","PeriodicalId":359138,"journal":{"name":"2016 IEEE International Energy Conference (ENERGYCON)","volume":"29 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133774281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}