Mohammad AlMa', N. Aitah, Mohammed I. Abuashour, M. Hattab, Omar M. Abdallah, N. Tha, E. O. Sweidan
{"title":"Optimisation of PID controller employing PSO algorithm for interleaved buck-boost power electronic converter","authors":"Mohammad AlMa', N. Aitah, Mohammed I. Abuashour, M. Hattab, Omar M. Abdallah, N. Tha, E. O. Sweidan","doi":"10.1504/ijied.2019.10023998","DOIUrl":"https://doi.org/10.1504/ijied.2019.10023998","url":null,"abstract":"In this paper, the optimisation of the PID controller employing the PSO algorithm for the interleaved buck-boost power converter is outlined. Currently, buck-boost power converters are broadly used in several application areas like the photovoltaic system, uninterruptable power supplies, and electric vehicle. The buck-boost power converter can be connected in parallel with one or more other buck-boost converters (multi phasing) or the interleaved configuration so less filtering requirement to suppress the ripple is needed and the effective resultant frequency is increased and thus high reliability and efficiency for the power converter is achieved. The switching pulses for these converters are sequenced or interleaved in time to give the required phase shift between the interleaved buck-boost converters. The control circuit for this interleaved buck-boost converter is tuned by the PSO algorithm. The system is tested firstly by changing the input voltage and secondly by changing the output load resistance. The Simulations and the operational dynamical performance of the interleaved buck-boost converter with PID controller employing PSO algorithm results are executed using MATLAB software.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125181520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A single phase shift-based isolated bidirectional DC-DC converter for bidirectional energy transfer in DC-microgrid with identification of optimum operating zone","authors":"Anupam Kumar, A. H. Bhat, P. Agarwal","doi":"10.1504/ijied.2019.10023995","DOIUrl":"https://doi.org/10.1504/ijied.2019.10023995","url":null,"abstract":"In the modern times, the pertinence of a single power electronics conversion system used in DC microgrids for facilitating energy transfer between energy generating systems and storage elements with inherent bidirectional capability has increased significantly. A dual active bridge (DAB) converter having two DC-AC converters connected back to back through a high frequency transformer is used as a power electronics conversion system for obtaining highly efficient bidirectional power conversion. In this paper, performance of DAB converter with single phase shift (SPS) is evaluated with solar photovoltaic cell on high voltage DC-bus and battery on the low voltage DC-bus. Linear load is connected in this system at the high voltage DC-bus. A step variation in load is applied and at this instant the power flows from the batteries to supply the increased load demand. Optimal operating range of converter along-with efficiency is obtained.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"106 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121813865","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"AC-, DC- and hybrid-configurations of photovoltaic-based houses","authors":"H. Awad, M. Fouad","doi":"10.1504/ijied.2019.10023994","DOIUrl":"https://doi.org/10.1504/ijied.2019.10023994","url":null,"abstract":"Typically, the photovoltaic (PV)-fed houses are based on AC networks. However, a transition to DC networks is currently running due to the proliferation of DC microgrids and the merits of DC systems. This paper considers three distinct designs: AC-based, DC-based and hybrid (AC and DC)-networks. A comparison between three configurations is done based on essential aspects such as the efficiency and the cost. Basic design features such as circuit breakers and cross section area of cables are included. Although the DC-based network has more merits compared to the AC-based network, problems such the DC circuit breakers and the availability of DC-based appliances still present some challenges. Thus, the study found that a proper combination of AC- and DC-based appliances is currently the best choice for PV-based houses.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"80 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121835779","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sensorless DTC of BDFRG using LMS algorithm for wind energy conversion systems","authors":"A. K. Ibrahim, M. Marei, H. El-Goharey","doi":"10.1504/ijied.2019.10023993","DOIUrl":"https://doi.org/10.1504/ijied.2019.10023993","url":null,"abstract":"This paper presents a new sensorless speed and secondary winding resistance estimation technique for brushless doubly fed reluctance generator (BDFRG) using least mean square (LMS) algorithm. Detailed mathematical derivation of the algorithm is explained and simulation results in MATLAB Simulink are shown for sensorless direct torque control (DTC) of BDFRG using LMS algorithm. A comparison to traditional speed estimation technique for BDFRG using primary winding flux linkage formula in stationary frame is then held to show the advantages of this proposed technique over the traditional method of speed estimation. Power electronics of the drive system is also simulated to consider effect of harmonics injected by electronic switches on both algorithms.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"157 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115589286","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A novel bidirectional converter control for plug-in electric vehicles","authors":"Y. M. Roshan, R. Sabzehgar","doi":"10.1504/ijied.2019.10023996","DOIUrl":"https://doi.org/10.1504/ijied.2019.10023996","url":null,"abstract":"In this paper, a novel bidirectional converter modelling and control is presented for the applications in plug-in electric vehicles. The controller is developed to enforce a pseudo-resistive behaviour at input terminals of the converter to ensure the unity power factor correction in power conversion. The proposed controller is based on a nonlinear sliding mode approach utilising a modified sliding manifold based on PI structure, as well as boundary layer solution to perform chattering compensation. The input resistance of the converter is regulated and controlled to positive and negative values depending on the charging or discharging state of the electric vehicle. Numerical simulations in PSIM environment are presented that evaluate performance of the proposed modelling and feedback control scheme.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"9 3","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114103943","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A suboptimal fuzzy-PI controller applied to a nonlinear system","authors":"M. Alsumiri","doi":"10.1504/IJIED.2018.10014887","DOIUrl":"https://doi.org/10.1504/IJIED.2018.10014887","url":null,"abstract":"In this paper, a suboptimal fuzzy-PI controller (SOFPIC) is introduced to improve the performance of fuzzy-PI controllers with respect to systems nonlinearities by integrating some tuning parameters. The structure, analysis, and some properties of the SOFPIC are discussed. To obtain the improved performance, some tuning parameters are required to be adjusted to their optimal values. For this task, particle swarm optimisation (PSO) is applied and assured its attainment. For testing the performance of the proposed fuzzy-PI controller, maximum power point tracking (MPPT) of stand-alone photovoltaics (PV) is selected due to the nonlinearity nature of PV and continuous changes of its parameters with the unpredictable change in the environmental conditions. Both simulation and experimental results show that the proposed controller is capable of improving the system performance radically within a wide range of the operating conditions.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117108496","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power quality improvement in hybrid filter using fuzzy logic controller","authors":"Amit Kumar, A. H. Bhat","doi":"10.1504/IJIED.2018.10014831","DOIUrl":"https://doi.org/10.1504/IJIED.2018.10014831","url":null,"abstract":"This paper presents the performance evaluation of a hybrid power filter for current harmonic elimination and improved input power factor. Hybrid filter consists of an active power filter and passive filters. In the proposed scheme shunt active power filter operates at very low frequency to achieve lower switching frequency and hence higher conversion efficiency. The combined operation of shunt active power filter and passive filter ensure THD of source current within the permissible limits set by various regulatory agencies and near unity supply power factor. The effectiveness of the hybrid filter has been verified by the extensive simulation results carried out in MATLAB/Simulink and SimPower systems software.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125337221","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Realisation and HIL testing of wind turbine emulator based on DTC squirrel cage induction motor drive","authors":"O. Arafa, M. E. Abdallah, G. A. A. Aziz","doi":"10.1504/IJIED.2018.10014891","DOIUrl":"https://doi.org/10.1504/IJIED.2018.10014891","url":null,"abstract":"Direct torque control (DTC) is known to produce the fastest torque response in AC drives. In this paper, a wind turbine emulation (WTE) system using a squirrel cage induction motor (SCIM) working in a DTC mode is designed, implemented, and tested experimentally using Hardware-in-loop (HIL). The flux estimation is based on the current model where two stator currents and the rotor speed are measured. The DTC is realised using a space vector modulator to avoid variable switching frequency associated with the DTC switching tables. dSPACE MicroLabBox is used to handle the real-time control programmed in SIMULINK. Typhoon HIL402 is used to emulate the inverter, the machine, the connected mechanical load, and the feedback sensors of the current dc link voltage and speed. Thanks to the great flexibility offered by the HIL technique, a variety of tests has been conducted to validate the overall system performance. The tests include step change of load, step change of wind speed, operation under stochastic wind speed variation and torque-speed characteristics' of the emulated wind turbine at different feeds of wind speeds and coupled mechanical loads. Testing results verified the perfect fit of DTC in WTE application and the effectiveness of the HIL testing technique.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129645711","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance of a PV-wind hybrid system under severe weather and loading conditions","authors":"M. Fathy, H. Awad, Hosam Hegarzy, E. El-Kholy","doi":"10.1504/IJIED.2018.10014888","DOIUrl":"https://doi.org/10.1504/IJIED.2018.10014888","url":null,"abstract":"In this paper, an extensive study on the operation, control and performance of a hybrid photovoltaic and wind turbine system is presented. The study includes the operation of the hybrid system under different weather conditions which are reflected as a change in the wind speed and irradiance. Various loading conditions are investigated such as a change in active and reactive power demands for static and dynamic loads. The performance of the hybrid system is examined via MATLAB/SIMULINK simulations.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"95 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126252279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Filterless pseudo-power-based sensorless commutation method for BLDC motors","authors":"Shahin Mahdiyoun Rad, M. Azizian","doi":"10.1504/IJIED.2018.10014856","DOIUrl":"https://doi.org/10.1504/IJIED.2018.10014856","url":null,"abstract":"This paper presents a new commutation technique for position-sensorless control of BLDC motors called as pseudo-power-based commutation method. The proposed method does not require any low-pass filter, because it utilises the unfiltered line-to-line voltages. Moreover, no phase shifter is needed. Unfiltered voltages have notches resulted from current commutation that deteriorate the commutation signals extracted from the motor line voltages. Therefore, it is proposed to use the pseudo-power signs of the three phases of the motor as the auxiliary signals to compensate the commutation ripples effects. This method does not involve speed-dependent phase-delay. The simulation has been run in MATLAB/Simulink and the real-time implementation has been done using Advantech PCI-1716 multifunction card to justify the effectiveness of the proposed method.","PeriodicalId":353307,"journal":{"name":"International Journal of Industrial Electronics and Drives","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129790364","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}