{"title":"Performance of Norton Code 7997 3µ Cut Rate Enhanced Precision Alumina Slurry","authors":"D. Rostoker","doi":"10.1364/AO.29.002822","DOIUrl":"https://doi.org/10.1364/AO.29.002822","url":null,"abstract":"In any lapping operation, especially when lapping precision optical materials, there is always a compromise between cut rate and finish. The most desirable finish is one that leaves the surface sufficiently smooth and free from sub-surface damage that reduces polishing time.","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116222838","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Estimation of Subsurface Damage Depth by Dimpling","authors":"L. Dettmann","doi":"10.1364/sciof.1990.smc2","DOIUrl":"https://doi.org/10.1364/sciof.1990.smc2","url":null,"abstract":"Sample Preparation- To test each of the methods of measuring subsurface damage, three fused silica samples were used. Two of the samples were one inch in diameter and one inch thick. These were ground using resin bonded diamond pellets bonded to a metal plate using a conventional Strasbaugh grinding machine. Both 12 and 30 micron diamond pellets were used. These were then diamond generated to approximately 1 mm thickness from the back. The back was then ground and polished using conventional techniques. The other sample began as a 1\"X3\" fused silica microscope slide that was generated on a swing arm generator with a 320-grit resin bonded diamond cup wheel.","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127835369","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Computer Simulations of Precision Ground Surfaces","authors":"Steven C. Fawcett, T. Dow","doi":"10.1364/sciof.1990.sma6","DOIUrl":"https://doi.org/10.1364/sciof.1990.sma6","url":null,"abstract":"The majority of precision refractive optical components are fabricated from brittle glasses. The fabrication usually involves grinding the desired contour of the component followed by polishing to remove the undesirable surface features. These surface features are remnants of the brittle fractures that occur in the grinding operation. Previous studies at the Precision Engineering Center have demonstrated the feasibility of achieving ductile material removal (Ductile Mode Grinding) on samples of brittle materials. Experimental measurements and analytical models have demonstrated the relationship between the depth of cut and the damage to the surface. The extrapolation of such one-dimensional critical depth information to three dimensions is being developed through computer simulations of the grinding process and the resulting chip geometry.","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"90 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133717248","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Surface Preparation Technique for Rapid Measurement of Sub-Surface Damage Depth","authors":"A. Lindquist, S. Jacobs, A. Feltz","doi":"10.1364/sciof.1990.smc3","DOIUrl":"https://doi.org/10.1364/sciof.1990.smc3","url":null,"abstract":"Most methods for fabrication of optical materials produce, in addition to the desired result (dimensional accuracy, surface figure, and surface roughness, etc.), the undesirable side effect of cracks or fractures in the material known as sub-surface damage. The \"sub\" prefix denotes the absence of clear evidence on the surface as to the existence of the damage below, particularly if the surface is subsequently polished. As a source of scattered light, figure instability, or in some cases, total failure of an optic, sub-surface damage can be detrimental in high precision optical systems. Detection and measurement of this sub-surface damage has become vital to the improvement of optical fabrication techniques. This paper describes the methods by which we detect and measure sub-surface damage (SSD).","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"05 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130482232","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Subsurface Damage in Optically Worked Glass","authors":"Robert E. Parks","doi":"10.1364/sciof.1990.smc1","DOIUrl":"https://doi.org/10.1364/sciof.1990.smc1","url":null,"abstract":"This paper is a summary of a conference on subsurface damage in glass that was held in Tucson in April, 1989 by the American Society for Precision Engineering. The conference was held to see if there was a consensus that subsurface damage did exist and did affect optical system performance. The answer was yes in both cases. Additional papers discussed methods of detecting subsurface damage and means of minimizing subsurface damage (SSD).","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130339703","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Physics of Felt: or One View of the Evolution of Optical Finishing Science","authors":"Chris Evans","doi":"10.1364/sciof.1990.ssa1","DOIUrl":"https://doi.org/10.1364/sciof.1990.ssa1","url":null,"abstract":"For some the \"science of optical finishing\" is an oxymoron. Others see the convergence of disparate cultures - and desperate manufacturers. This talk aims to pose questions, not offer any answers.","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"215 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133746777","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Chemo-Mechanical Effects in Loose Abrasive Grinding of ULE","authors":"D. Golini, S. Jacobs","doi":"10.1364/sciof.1990.sma4","DOIUrl":"https://doi.org/10.1364/sciof.1990.sma4","url":null,"abstract":"This study examined chemo-mechanical effects in loose abrasive microgrinding (grinding with micron and sub-micron sized abrasives). The work was directed specifically at understanding loose abrasive grinding dependency on slurry fluid chemistry. Several slurry fluids were investigated, including water, a homologous series of n-alcohols, and several other organics selected for various properties including molecular size and dielectric constant. Chemistry was found to play a major role in this process; in fact, by simply changing slurry fluid composition, it was possible to induce the transition from brittle fracture to ductile mode grinding in ULE® (Corning Code 7971 Titanium Silicate Low Expansion Glass). Data revealed that the dependency of loose abrasive grinding on slurry chemistry can best be explained as Rebinder-Westwood chemo-mechanical effects [1-4].","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123347739","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Using Instrumented Indentation For Subsurface Damage Measurements","authors":"R. Polvani, C. Evans","doi":"10.1364/sciof.1990.smc4","DOIUrl":"https://doi.org/10.1364/sciof.1990.smc4","url":null,"abstract":"Even unusual care in polishing, leads to optics with somewhat damaged faces. The question is to what degree? We will show instrumented indentation is a versatile, quick way to give an answer. Limited power, detail size, or durability are accepted hazards of subsurface damage. Its form varies: ductile materials damage by hardening, and brittle ones have fractured surfaces.","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123348164","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ultra-Precision Grinding of Optical Materials to Produce Smooth Optical Components","authors":"Y. Namba","doi":"10.1364/sciof.1990.smb1","DOIUrl":"https://doi.org/10.1364/sciof.1990.smb1","url":null,"abstract":"Optical glasses of brittle in nature have been machined into optical components by using grinding, lapping and polishing processes in industries. Recently, ductile regime grinding has been developped under the stimulus of the success of single point diamond turning in metal mirrors of soft metals.","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122011261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of Polished Optical Glasses with a MAI—MWL Ellipsometer Arrangement","authors":"M. Linder","doi":"10.1364/sciof.1990.smc5","DOIUrl":"https://doi.org/10.1364/sciof.1990.smc5","url":null,"abstract":"Surface layers are investigated by means of MAI–MWL (multiple angle of incidence, multiple wavelength) ellipsometry. The \"layers\" investigated are modifications of optical glasses in the near-surface region, caused by polishing and cleaning processes. The influence of several treatments on different materials is discussed.\u0000 The device used is a new, special ellipsometer arrangement using only absolutely nescessary elements but allowing fast and very accurate measurements.","PeriodicalId":351931,"journal":{"name":"Science of Optical Finishing","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128182755","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}