Saman A. Gorji, M. Ektesabi, T. Nguyen, Jinchuan Zheng
{"title":"Galvanically isolated switched-boost-based DC-DC converter","authors":"Saman A. Gorji, M. Ektesabi, T. Nguyen, Jinchuan Zheng","doi":"10.1109/ECCE.2016.7855129","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7855129","url":null,"abstract":"A new galvanically isolated DC-DC converter has been presented in this paper. The proposed topology is based on the quasi-switched-boost impedance network. It not only includes all positive characteristics of previous converters including continuous input current, high boost ability and high efficiency, but also has the prominent features of less passive elements utilization, small size and light weight. The proposed converter has been analyzed and inspected in the steady state. Furthermore, other possible galvanically isolated switched boost dc-dc topologies have been obtained by altering the switching network. Theoretical analysis has been verified by simulations as well as the experiments.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"15 9","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121122234","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A grid-interfaced test system for modeling of NiMH batteries in a battery-buffered smart load application","authors":"Ahmed Zurfi, Jing Zhang","doi":"10.1109/ECCE.2016.7854690","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7854690","url":null,"abstract":"Testing and modeling of batteries are essential to evaluate the performance and effectiveness of battery energy storage systems (BESS) in power system applications. The procedure of extraction and experimental verification of any battery model require a reliable and efficient testing system. In this paper, a programmable grid-interfaced battery test system for battery modeling in a frequency-controlled battery-buffered smart load application is proposed. The testbed is based on the same smart load experimental system which consists of a single phase bidirectional AC-DC converter, a DC-link, and a bidirectional DC-DC converter. The AC-DC converter is designed to control a bidirectional power flow between the AC-line and the DC-link. Therefore, the energy can be controlled effectively flowing between the battery and the power line during charge and discharge without significant power losses. This design realizes an energy-conserving electronic load by supplying the battery energy to the grid instead of dissipating it during discharge. To verify the functionality of the developed test system, 3Ah, 1.2V NiMH batteries were tested for a Thevenin-based model identification. Then, a simulation of the identified model was implemented in MATLAB/Simulink to validate the model under the smart load charging and discharging conditions.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121213199","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Guangjie Ke, Qianhong Chen, Ligang Xu, Siu-Chung Wong, C. Tse
{"title":"A model for coupling under coil misalignment for DD pads and circular pads of WPT system","authors":"Guangjie Ke, Qianhong Chen, Ligang Xu, Siu-Chung Wong, C. Tse","doi":"10.1109/ECCE.2016.7854706","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7854706","url":null,"abstract":"The coupling coefficient of a transformer is a key parameter affecting the performance of a wireless power transmission system. Based on the magnetic reluctance model under aligned condition, this paper gives an effective method for calculating the null coupling position, as well as a practical and accurate model for finding the coupling coefficient under coil misalignment and varying air gap. The null coupling position is determined by the horizontal offset when the flux of opposite direction that is intersected with the receiving coil is cancelled out. An empirical formula is given to correct the null coupling position. Based on the physics of coupling under misaligned conditions, a practical model for coupling is constructed. Transformers with DD structure and typical circular structure are fabricated for verification. Experimental measurement validates the model.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127170224","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Magnetic field analytical computation in synchronous reluctance machines considering the iron saturation","authors":"H. Mahmoud, N. Chiodetto, N. Bianchi","doi":"10.1109/ECCE.2016.7855229","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7855229","url":null,"abstract":"This paper deals with an analytical model of REL motor considering the stator slotting effect and the magnetic saturation in the stator and rotor iron paths. It joints the field distribution at the air-gap to a lumped-parameter magnetic network. As an example, 36-slot 4-pole machine is analyzed, considering three flux barriers per pole. Finite element analysis confirms the results achieved by means of the analytical model.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"120 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127343450","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sanghoon Kim, Ashraf Ali Khan, Honnyong Cha, H. Ahmed
{"title":"A reliable cascaded AC-AC converter","authors":"Sanghoon Kim, Ashraf Ali Khan, Honnyong Cha, H. Ahmed","doi":"10.1109/ECCE.2016.7854766","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7854766","url":null,"abstract":"This paper presents a new type of cascaded PWM ac-ac converter with phase-shift PWM control. It can reach high output voltage by cascading single-phase units of low voltage rating devices. The proposed converter does not sense current/voltage polarity, and does not require current/voltage sensors and lossy snubbers for commutation, thereby the control complexity can be decreased. It has no shoot-through problem and eliminates the PWM dead times, which leads to greatly enhanced system reliability. The phase shift PWM control is also proposed for the proposed converter to reduce the volume of passive components, and current and voltage ripples. In order to verify the robustness of the proposed converter, a 1 kW hardware prototype converter having two-unit cell structure is fabricated and tested.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124912529","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Minghui Lu, Zhen Xin, Xiongfei Wang, R. Beres, F. Blaabjerg
{"title":"Extended stable boundary of LCL-filtered grid-connected inverter based on an improved grid-voltage feedforward control","authors":"Minghui Lu, Zhen Xin, Xiongfei Wang, R. Beres, F. Blaabjerg","doi":"10.1109/ECCE.2016.7855103","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7855103","url":null,"abstract":"For the LCL-filtered grid-connected inverter, it has been reported that the digital time delays will narrow the stable region of current control loop when the inverter-side current is used for implementing the feedback control. A sufficient stable condition is that the filter resonance frequency should be designed under one-sixth of sampling frequency. However, the low resonance frequency leads to a comparatively large filter inductance or/and capacitance. To extend the stable boundary to the region above fs/6, this paper proposes a novel voltage feedforward scheme for the LCL-filtered inverter. Theoretical analysis is then provided to validate its feasibility and stability. Compared to other widely used active damping strategies, no extra sensors are needed because the filter capacitor voltage, which is used for voltage feedforward control, is also sampled for phase-locked loop in this paper. Simulations and experimental results are provided for verifying the theoretical analyses.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125131293","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Kai Li, Zhengming Zhao, Liqiang Yuan, Sizhao Lu, Ye Jiang
{"title":"Fault detection and tolerant control of open-circuit failure in MMC with full-bridge sub-modules","authors":"Kai Li, Zhengming Zhao, Liqiang Yuan, Sizhao Lu, Ye Jiang","doi":"10.1109/ECCE.2016.7855109","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7855109","url":null,"abstract":"Modular multilevel converter (MMC) has drawn tremendous attention in the academia and industry since its invention, and it is considered as a very suitable solution for the high-power applications. It is usually composited by a large number of half-bridge or full-bridge sub-modules (SMs), which makes the reliability as one of the most important challenges for MMC. Besides, due to the DC side short-circuit blocking and ride-through capability, MMC with full-bridge SMs is very competitive and will be widely used in the future. Considering the IGBT open-circuit failure in MMC with full-bridge SMs, the fault features are analyzed in detail in this paper. Then a complete set of fault detection and tolerant control strategy is proposed. Firstly, the IGBT open-circuit fault is detected based on two sliding mode observers for the circulating current and the output current, respectively. Secondly, a tolerance period is inserted immediately to make the transient process smooth. Thirdly, the failed SM is localized through comparing all the capacitors' voltages. Finally, the failed SM is bypassed and the other healthy SMs are reconfigured to realize the continuous operation. The feasibility and effectiveness of the proposed fault detection and tolerant control strategy have been confirmed through the simulations in MATLAB/Simulink.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125184784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hui Li, K. Yao, Xufeng Zhou, Fei Yang, Junfang Zhang
{"title":"A novel online ESR and C identification method for output capacitor of flyback converter","authors":"Hui Li, K. Yao, Xufeng Zhou, Fei Yang, Junfang Zhang","doi":"10.1109/ECCE.2014.6953873","DOIUrl":"https://doi.org/10.1109/ECCE.2014.6953873","url":null,"abstract":"As electrolytic capacitor is apt to fail in power system, it is very important to monitor its ESR and C. A novel online monitoring method of capacitor's ESR and C for DCM Flyback Converter is proposed in this paper. Based on the ac component of capacitor voltage, the calculation model is founded. The method needs no current sensor and is effective for the converter operating at any switching frequency and duty cycle. The simulation results validate the effectiveness of the method.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"128 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123275705","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Step-up MMC with staircase modulation: Analysis, control, and switching strategy","authors":"Y. Sangsefidi, A. Mehrizi‐Sani","doi":"10.1109/ECCE.2016.7855473","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7855473","url":null,"abstract":"Modular multilevel converters (MMC) provide a low-harmonic output voltage without needing several isolated power sources. This multilevel converter can use either half-bridge or full-bridge submodules with PWM or staircase modulation techniques. This paper analyzes the full-bridge MMC, which is called step-up MMC because of its boosting capability, using the staircase modulation. Different operational modes of the step-up MMC are studied, and a generalized control and switching algorithm is proposed. This algorithm ensures the capacitor charge balance while providing the required high-quality output voltage. Compared to a half-bridge MMC with a similar investment in capacitor and switches, the step-up MMC shows a superior performance as it has 1) low total harmonic distortion (THD) of the output waveform, 2) high output voltage with a low input DC voltage, and 3) the possibility to provide different achievable output voltages using submodules with negative voltage at their terminals. The performance of the proposed step-up MMC with staircase modulation and presented theories are validated by simulation case studies.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123418650","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High speed operation of permanent magnet machine position sensorless drive using discretized EMF estimator","authors":"Shih-Chin Yang, Guan-Ren Chen","doi":"10.1109/ECCE.2016.7855155","DOIUrl":"https://doi.org/10.1109/ECCE.2016.7855155","url":null,"abstract":"This paper proposes a permanent magnet (PM) machine position sensorless drive for high speed (>10-krpm) applications. A fully discretized back electromotive force (EMF) estimator is designed to overcome several high speed rotor position estimation issues, including the voltage error due to pulse-width-modulation (PWM), dq inductance cross-coupling effect and the deviation between the estimated EMF and actual EMF resulting from the digital implementation. To overcome these problems, an observer-based EMF estimator is proposed with two implementation considerations. They are i) a discretized dq current observer to minimize the inductance cross-coupling effect on the estimated EMF voltages, and ii) a PWM model considering the EMF cross-coupling effect to obtain actual EMF voltages. A high speed PM machine is experimentally tested to verify all proposed sensorless drive methods.","PeriodicalId":345511,"journal":{"name":"2016 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123530309","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}