{"title":"A Novel True-Mode Balanced Measurement using Mixed-mode Power waves","authors":"Xin Chen, J. Dunsmore, K. Anderson","doi":"10.1109/ARFTG47584.2020.9071707","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071707","url":null,"abstract":"Mixed-mode (Combined differential-mode and common-mode) s-parameters are well adapted to accurate measurements of linear networks. Most of current measurements are using standard s-parameters to compute the mixed-mode S parameters. In this paper, a new measurement system is introduced for measurement of the mixed-mode power waves. And with the mixed-mode power waves, the mixed-mode S parameters are calculated by the mixed-mode scattering matrix.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"2 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114018744","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Waveguide Probe Calibration Method for Permittivity and Loss Characterization of Viscous Materials","authors":"Seckin Sahin, N. Nahar, K. Sertel","doi":"10.1109/ARFTG47584.2020.9071773","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071773","url":null,"abstract":"We present a new measurement technique based on reduced-reflectometer calibration of a waveguide with a highly-reflecting termination for the complex permittivity characterization of viscous materials. In this novel method, the waveguide is simply dipped into the viscous material at 4 different depths, separated roughly by $lambda/8$, and the reflection coefficients are recorded. Subsequently, a multi-reflect calibration procedure is applied to these measurements to determine the propagation constant of material-filled waveguide. The complex permittivity of the material is then extracted from the calculated propagation constant. The proposed approach is very simple and cost-effective, as it only requires a one-port network analyzer, and is applicable to the wide range of frequencies. We show the validity of this new technique by characterization of olive oil over 90-130 GHz band.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126379540","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Calibration Substrate Design for Accurate mm-Wave Probe-Tip Calibration","authors":"A. Rumiantsev, R. Doerner, G. Phung","doi":"10.1109/ARFTG47584.2020.9071757","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071757","url":null,"abstract":"This work presents the design concept, EM-simulation and measurement results of a new calibration substrate developed to address probe-tip calibration challenges and to improve calibration accuracy at mm-wave frequency range.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121602390","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Nagma Vohra, Luis R. Rodriguez-Aguilar, Jose Santos Batista, M. El-Shenawee
{"title":"Free-Space Characterization of Radar Absorbing Non-Magnetic Materials in the W-Band","authors":"Nagma Vohra, Luis R. Rodriguez-Aguilar, Jose Santos Batista, M. El-Shenawee","doi":"10.1109/ARFTG47584.2020.9071679","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071679","url":null,"abstract":"In this paper, a time gated free-space measurement setup for characterizing radar absorbing non-magnetic materials at W-band is presented. The measurement setup uses a pair of horn lens antennas and a two micrometer precise positioning fixture that allows the use of thru, reflect, and line (TRL) calibration technique for the error corrections. The measurements are performed using a network analyzer with the millimeter wave frequency extenders to provide four S-parameters over the W-band. The implemented extraction method provides the correct complex permittivity values of the samples. Excellent agreement is achieved between the calculated and measured S-parameters of the samples.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131656831","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Gillet, J. Verspecht, J. Teyssier, M. Prigent, R. Quéré
{"title":"Arbitrary wideband open-loop active load-pull measurement using Unequally Spaced Multi-Tone stimulus","authors":"V. Gillet, J. Verspecht, J. Teyssier, M. Prigent, R. Quéré","doi":"10.1109/ARFTG47584.2020.9071709","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071709","url":null,"abstract":"This paper presents an implementation of active load-pull measurements. This set-up uses the innovative Unequally Spaced Multi-Tone (USMT) wideband test signal in order to assess the in-band linearity degradation of non-linear microwave power devices. The proposed test bench is suitable for both on-wafer and connectorized devices characterization.A proof of concept of the arbitrary wide open-loop active load-pull measurement using 8-tones USMT has been detailed, using 90 MHz bandwidth with a VSWR of 10:1 on an in-house power amplifier. Load tuning is achieved by reinjecting both the carrier tones and third order intermodulation tones at the output of the amplifier.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133347105","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Method to Remove the Effects of LO Drift from Vector Network Analyzer Measurements","authors":"A. Arsenovic","doi":"10.1109/ARFTG47584.2020.9071755","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071755","url":null,"abstract":"This paper describes the effects of LO-drift in VNA scattering parameter measurements and demonstrates an analytical technique to correct for this error. It is shown that LO drift has a limited effect on the process of error correction. Specifically, for calibration algorithms employing a single transmissive standard, such as SOLT, only the phase of corrected measurements are affected. A technique to remove the LO-drift from reciprocal devices is presented. Measurements in the 500750GHz band are given with intentionally induced LO-drift to demonstrate effectiveness and limitations of the technique. This technique, which we refer to as undrifting, can be applied in post processing if sufficient data is recorded during the measurement process. Thus, measurements that have been previously made can have the errors of LO drift removed. Eight Ten Labs LLC has patent on this technique.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"1 5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117280922","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement of the Channel Temperature of a GaN Microwave Power Transistor During Pulsed I.V Excitation","authors":"C. Matei, H. Votsi, P. Aaen","doi":"10.1109/ARFTG47584.2020.9071729","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071729","url":null,"abstract":"In this paper a thermoreflectance measurement technique is used to capture the channel temperature within a GaN-on-Si HEMT during pulsed I-V excitation. Using pulsed I-V measurements in combination with thermoreflectance measurements allows the direct assessment of the isothermal approximation that is often made during the characterization of the transistor for nonlinear model development. The thermoreflectance measurement has a temporal response of 50 ns, which is sufficiently fast to measure the temperature rise within the pulsed I-V excitation, across the I-V plane of the transistor. We first determine the minimum pulse duration needed to minimize the temperature rise as assessed from drain current measurements as a function of the excitation pulse width. The thermoreflectance measurements show that self-heating occurs during the pulse, revealing a maximum of 13.5°C change over all pulsed I-V measurements. Transient thermoreflectance measurements were then performed to determine that sub-200 ns pulses are required to eliminate the self-heating for this device.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116620805","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Characterization of Thermal and Trapping Time Constants in a GaN HEMT","authors":"K. Kellogg, S. Khandelwal, L. Dunleavy, Jing Wang","doi":"10.1109/ARFTG47584.2020.9071731","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071731","url":null,"abstract":"A commercial pulsed-IV system is used to test a GaN HEMT with the purpose of extracting exponential time constants used for dynamic electro-thermal and charge-carrier trapping models. The time constants of these different physical phenomena can not only vary by many orders of magnitude, but also have regions of overlap. Self-heating and trapping are common phenomena affecting GaN HEMTs, thus characterization and understanding these dynamics is critical for developing accurate compact models. We investigated the approach of recording the drain current transient response under a careful selection of the bias conditions, to approximately separate the two phenomena to derive useful estimate of the different associated time constants. Modeling of these time constants is of concern for modulated signal processing, where they fall within typical bandwidths of modern communication systems.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129225003","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Broadband 220 GHz network analysis: structures and performance","authors":"J. Martens, T. Roberts","doi":"10.1109/ARFTG47584.2020.9071774","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071774","url":null,"abstract":"As mm-wave applications continue to increase in frequency and, simultaneously, the broadband measurement needs for the underlying device and subsystem development work spread, continuous network analyzer coverage beyond 200 GHz can be helpful. One such system uses an extension of an existing multiplied source multiplexing scheme and a modified shaped-LO converter structure to achieve power leveling over more than a 40 dB range from 70 kHz to 226 GHz, high receiver linearity, a noise floor below -100 dBm across the band, and $sim lt 0.1$ dB thru transmission measurement stability over 24 hours.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131345976","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. Clarke, X. Shang, N. Ridler, R. Lozar, T. Probst, U. Arz
{"title":"An interlaboratory study of the reproducibility of on-wafer S-parameter measurements from 140 GHz to 220 GHz","authors":"R. Clarke, X. Shang, N. Ridler, R. Lozar, T. Probst, U. Arz","doi":"10.1109/ARFTG47584.2020.9071783","DOIUrl":"https://doi.org/10.1109/ARFTG47584.2020.9071783","url":null,"abstract":"The development, modelling and characterization of millimeter-wave semiconductor devices calls for accurate and reproducible on-wafer measurements. We report on an interlaboratory study involving on-wafer S-parameter measurements in the 140 GHz to 220 GHz band, conducted by three well-established measurement laboratories. The measurements can be used to form typical reproducibility limits for these measurements when conducted in different laboratories using different equipment and calibration methods.","PeriodicalId":343502,"journal":{"name":"2020 94th ARFTG Microwave Measurement Symposium (ARFTG)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132772971","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}