{"title":"Revolutionizing respiratory health research: “commercially-available lung-on-a-chip and air-liquid interface systems”","authors":"Sohyun Park, Chang Gyu Woo, Young-Jae Cho","doi":"10.3389/frlct.2024.1373029","DOIUrl":"https://doi.org/10.3389/frlct.2024.1373029","url":null,"abstract":"Inhalation of ultrafine particles, aerosol contaminants, and cigarette smoke can induce respiratory diseases. As humans are constantly exposed to various exogenous substances, it is crucial to study their impacts on respiratory diseases and airway dysfunction. Recently, organ-on-a-chip technology has been applied in many research studies to understand disease mechanisms, drug screening, and drug testing. The combination of organ-on-a-chip technology and the air-liquid interface (ALI) culture method is emerging as a new platform for realistically mimicking the microenvironment and physiological motions of the human lungs. Breathing motion can be simulated through cyclic stretching, while blood flow can be replicated using channel flow within the chip. The ALI system is critical for mucociliary differentiation, pseudostratified morphology, and epithelial barrier function development. The combination of organ-on-a-chip technology and ALI systems allows the integration of cyclic stretch as a breathing motion and microfluidic channels as circulatory systems. The chip system can also integrate the lung epithelial cells, extracellular matrix, and microstructures, providing microenvironments such as fibroblast, collagen, and immune cells to the epithelial cells. This review discusses chip systems as effective tools for recapitulating human lung environments and how they are applied in biological studies against various pulmonary diseases such as infections or inflammation, fibrosis, and malignancy.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"39 17","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141356728","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Dominika Schrödter, Mohadeseh Mozafari, Janine Fichtner, J. W. von Trotha, Reinhard Wolfgang Köster, Andreas Dietzel
{"title":"A 3D tailored monolithic glass chip for stimulating and recording zebrafish neuronal activity with a commercial light sheet microscope","authors":"Dominika Schrödter, Mohadeseh Mozafari, Janine Fichtner, J. W. von Trotha, Reinhard Wolfgang Köster, Andreas Dietzel","doi":"10.3389/frlct.2024.1346439","DOIUrl":"https://doi.org/10.3389/frlct.2024.1346439","url":null,"abstract":"Microfluidic technology is unrivaled in its ability to apply soluble chemical stimuli with high spatiotemporal precision. Analogous, light–sheet microscopy is unmatched in its ability of low phototoxic but fast volumetric in vivo imaging with single cell resolution. Due to their optical translucency during the larval stages, zebrafish (Danio rerio) are an ideal model to combine both techniques; yet, thus far this required light–sheet microscopes, which were in most cases custom–built and adapted to the available softlithographic chip technology. Our aim was to use a commercial light–sheet microscope to illuminate a microfluidic chip from two opposite lateral directions and to record images with the detection objective placed orthogonally above the chip. Deep tissue penetration can be achieved by superimposing beams from opposite directions to form a single light sheet. But a microfluidic chip that allows a) targeted stimulus application in a closed microenvironment, b) interference–free incoupling of excitation light from two directions and c) outcoupling of fluorescence in the perpendicular direction through an optically perfect cover glass was not known until now. Here, we present a monolithic glass chip with the required plane-parallel sidewalls and cover slide closure at the top, constructed by advanced femtosecond laser ablation, thermal bonding and surface smoothing processes. In addition, the 3D shape of a fish fixator unit was tailored to match the body shape of a zebrafish larva to ensure stable positioning during whole–brain recording. With hydrodynamic focusing a targeted partial exposure of the larva’s head to chemical stimuli and fast position switching (in less than 10 s) was possible. With the capabilities of this unique monolithic glass chip and its up–scalable wafer–level fabrication process, the new NeuroExaminer is prone to become an excellent addition to neurobiology laboratories already equipped with high–quality commercial light sheet microscopes.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"38 31","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140253374","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Organs in orbit: how tissue chip technology benefits from microgravity, a perspective","authors":"Aditi Jogdand, Maxwell Landolina, Yupeng Chen","doi":"10.3389/frlct.2024.1356688","DOIUrl":"https://doi.org/10.3389/frlct.2024.1356688","url":null,"abstract":"Tissue chips have become one of the most potent research tools in the biomedical field. In contrast to conventional research methods, such as 2D cell culture and animal models, tissue chips more directly represent human physiological systems. This allows researchers to study therapeutic outcomes to a high degree of similarity to actual human subjects. Additionally, as rocket technology has advanced and become more accessible, researchers are using the unique properties offered by microgravity to meet specific challenges of modeling tissues on Earth; these include large organoids with sophisticated structures and models to better study aging and disease. This perspective explores the manufacturing and research applications of microgravity tissue chip technology, specifically investigating the musculoskeletal, cardiovascular, and nervous systems.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"21 98","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140260233","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mónica Gabriela Sánchez-Salazar, Regina Garza-Garza, Regina Crespo-López Oliver, Valeri Sofía Jerezano-Flores, Salvador Gallegos-Martínez, Sofía Ramos-Meizoso, Manuel Verduzco-Valenzuela, G. Trujillo‐de Santiago, Mario Moisés Alvarez
{"title":"Continuous inline monitoring of glucose in an organ-on-chip using FreeStyle™ libre glucometers","authors":"Mónica Gabriela Sánchez-Salazar, Regina Garza-Garza, Regina Crespo-López Oliver, Valeri Sofía Jerezano-Flores, Salvador Gallegos-Martínez, Sofía Ramos-Meizoso, Manuel Verduzco-Valenzuela, G. Trujillo‐de Santiago, Mario Moisés Alvarez","doi":"10.3389/frlct.2024.1289437","DOIUrl":"https://doi.org/10.3389/frlct.2024.1289437","url":null,"abstract":"Introduction: Organ-on-chips have become an effective platform for studying the physiology of tissues and organs and for evaluating the safety and efficacy of drugs. In these systems, the inline monitoring of key parameters of biological performance (i.e., glucose, oxygen, or lactic acid concentrations) provides valuable information regarding the cell/tissue physiological state. However, significant limitations still exist when attempting to obtain inline information in these systems, and the microsensing technology of on-chip measurement of key parameters is still limited by size, cost, and availability.Methods: Here, we demonstrate the use of a commercially available glucometer (FreestleTM Libre; Abbott), normally used for continuous determination of blood glucose levels, to provide continuous inline measurements of the glucose concentration in tumor-on-chips. Here, we employed a colorectal tumor-on-chip as a first demonstration model and measured the on-chip concentration of glucose continuously for extended culture times (2 weeks).Results and Discussion: We show that inline glucose readings are reproducible and enable the accurate determination of glucose consumption rates (GCRs) by a tumor cell culture. In turn, the GCR measurements provide valuable information regarding the changes in the metabolic activity of the on-chip cultures following inlet perturbations (i.e., delivery of pulses of glucose, culture media additives, and drugs). Inline continuous glucose sensors will be useful tools in organ-on-chip research and will greatly enable cancer research in tumor-on-chip systems.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"8 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140409777","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"More small tools for sweet challenges: advances in microfluidic technologies for glycan analysis","authors":"Ferra Pinnock, J. Carten, Susan Daniel","doi":"10.3389/frlct.2024.1359183","DOIUrl":"https://doi.org/10.3389/frlct.2024.1359183","url":null,"abstract":"Carbohydrates, also known glycans, are ubiquitous in nature and exhibit a wide array of biological functions essential to life. Glycans often exist as conjugates of proteins or lipids and reside predominantly at the surface of cells, where their structure and composition are known to vary in a disease-dependent fashion. This observation has encouraged the development of tools for monitoring glycan patterns on individual molecules, cells, and tissues, to elucidate the links between glycosylation and disease for therapeutic and diagnostic applications. Over the past 2 decades, microfluidic technology has emerged as an advantageous tool for profiling the glycan content of biological systems. Miniaturizing carbohydrate analysis can circumvent several challenges commonly encountered with conventional-scale analytical techniques such as low throughput and poor detection sensitivity. The latter is often complicated by the low abundance of glycans in biological specimens and the complexity of carbohydrate structures, which often necessitates extensive concentration and purification of glycans to discern their structural features. We previously examined the application of microfluidics in the synthesis of carbohydrates in a recent paper (Pinnock et al., Anal. Bioanal. Chem., 2022, 414 (18), 5139–63). This review builds upon that discussion by delving into the application of microfluidics in the complementary field of carbohydrate analysis. Special attention is given to applications related to glycomics and the ways that microfluidics have enhanced the sensitivity, reproducibility, and throughput of carbohydrate identification and structural characterization.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"256 14","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140448258","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nanofluidic systems for ion transport with tunable surface charges: fabrications, characterizations, and applications","authors":"Dachuang Shi, Le Zhou, Zhigang Li","doi":"10.3389/frlct.2024.1356800","DOIUrl":"https://doi.org/10.3389/frlct.2024.1356800","url":null,"abstract":"Nanofluidics deals with the statics and dynamics of simple and complex fluids in systems with at least one dimension below 100 nm. Under strong nanoconfinements, flows may show diverse phenomena, which find rich applications in a variety of areas. In the past decades, nanofluidics has attracted great interest. Particularly, surface charge-governed ion transport in nanofluidic systems shows new flow fashions that cannot be observed in bulk systems and have been applied in different fields in science and engineering. These applications have motivated many efforts in developing surface charge-governed nanofluidic systems, including device fabrications and characterizations. Recent advances in nanotechnology have led to significant progress in surface modifications, which offer new opportunities for surface charge-governed nanofluidics systems. In this review, we discuss recent development of nanofluidic systems with tunable surface charges. Specifically, relevant theories, experimental approaches, and performance comparisons regarding the state-of-the-art fabrication techniques, characterization methods, and applications are presented. Finally, we provide a perspective about the possible future topics and applications for advancing nanofluidic systems with tunable surface charge properties.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"26 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139684602","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Lab-on-a-chip—fostering a sustainable future","authors":"Giulia Core","doi":"10.3389/frlct.2023.1239134","DOIUrl":"https://doi.org/10.3389/frlct.2023.1239134","url":null,"abstract":"","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"194 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133545553","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Droplet microfluidic technologies for next-generation high-throughput screening","authors":"Mushtaq Ali, Woohyuk Kim, Jinsoo Park","doi":"10.3389/frlct.2023.1230791","DOIUrl":"https://doi.org/10.3389/frlct.2023.1230791","url":null,"abstract":"Droplet microfluidics has evolved into a promising platform for high-throughput screening (HTS), allowing for rapid and precise analysis of thousands of samples encapsulated within droplets. Droplet microfluidic platform offers versatility, high-throughput, and the ability to compartmentalize reactions for a wide range of applications including pharmaceutics, cell analysis, and combinatorial chemical analysis. While droplet-based microfluidics has made considerable advances in automating basic laboratory tasks, for instance, manipulation, storage, and analysis, there has been comparatively little advancement toward HTS applications. The complexity of the technology, the lack of standardization, and the challenges associated with screening large numbers of samples are all factors that have contributed to the limited adoption of droplet-based microfluidics in HTS. In this perspective, we provide a comprehensive overview of the progress of droplet microfluidics as a potential platform for next-generation HTS, specifically in the domain of droplet separation and library generation. We hope that this perspective will inspire further research in relevant academic fields and contribute to the development of innovative HTS strategies based on droplet microfluidic technologies.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129855965","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An electrochemical device to control sample pH locally in Lab-on-PCB devices: An investigation into spatial resolution","authors":"Grace Maxted, P. Estrela, D. Moschou","doi":"10.3389/frlct.2022.1035423","DOIUrl":"https://doi.org/10.3389/frlct.2022.1035423","url":null,"abstract":"During the recent pandemic outbreak, Lab-on-Chip devices did not manage to fully reach their potential in rapid diagnosis of pathogens, mainly due to the lack of cost-effective LoC solutions integrated with all required sample preparation modules. This paper presents such a critical step, aiming to translate electrochemical pH control into practical protein preconcentration modules, easy to integrate with subsequent quantification modules seamlessly via Lab-on-PCB technology. In this work we present a device capable of electrochemically controlling the pH of a solution local to an individually addressed electrode in a PCB array. The electrodes were functionalised with an electropolymerised self-assembled monolayer of 4-Aminothiophenol and were subjected to voltages of 0.2–0.4 V, evaluating for the first time the bias effect both over time and over space. This study enables for the first time the implementation of this technique for electrochemical pH control into practical Lab-on-PCB devices such as isoelectric focusing, via the informed design of such electrode arrays of appropriate size and spacing.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128385061","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Low-cost microfluidics: Towards affordable environmental monitoring and assessment","authors":"Pedro Mesquita, Liyuan Gong, Yang Lin","doi":"10.3389/frlct.2022.1074009","DOIUrl":"https://doi.org/10.3389/frlct.2022.1074009","url":null,"abstract":"Effective environmental monitoring has become a worldwide concern, requiring the development of novel tools to deal with pollution risks and manage natural resources. However, a majority of current assessment methods are still costly and labor-intensive. Thanks to the rapid advancements in microfluidic technology over the past few decades, great efforts have been made to develop miniaturized tools for rapid and efficient environmental monitoring. Compared to traditional large-scale devices, microfluidic approaches provide several advantages such as low sample and energy consumption, shortened analysis time and adaptabilities to onsite applications. More importantly, it provides a low-cost solution for onsite environmental assessment leveraging the ubiquitous materials such as paper and plastics, and cost-effective fabrication methods such as inkjet printing and drawing. At present, devices that are disposable, reproducible, and capable of mass production have been developed and manufactured for a wide spectrum of applications related to environmental monitoring. This review summarizes the recent advances of low-cost microfluidics in the field of environmental monitoring. Initially, common low-cost materials and fabrication technologies are introduced, providing a perspective on the currently available low-cost microfluidic manufacturing techniques. The latest applications towards effective environmental monitoring and assessment in water quality, air quality, soil nutrients, microorganisms, and other applications are then reviewed. Finally, current challenges on materials and fabrication technologies and research opportunities are discussed to inspire future innovations.","PeriodicalId":343386,"journal":{"name":"Frontiers in Lab on a Chip Technologies","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128648321","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}