Y. Gyzhko, M. Gutorova, V. Zvaritch, G. Kuzik, M. Myslovych, L. Ostapchuk, V. Titko
{"title":"APPLICATION OF MULTILEVEL SYSTEMS FOR SOLVING PROBLEMS OF MONITORING AND DI-AGNOSTICS OF ELECTRICAL EQUIPMENT UNITS","authors":"Y. Gyzhko, M. Gutorova, V. Zvaritch, G. Kuzik, M. Myslovych, L. Ostapchuk, V. Titko","doi":"10.15407/publishing2023.66.150","DOIUrl":"https://doi.org/10.15407/publishing2023.66.150","url":null,"abstract":"Features of the construction and practical application of multi-level information and measurement systems for monitoring and diagnostics of electrical equipment are considered. The results of the construction and research of mathematical models of some diagnostic signals (acoustic emission, vibrations) accompanying the operation of electrical equipment units (including powerful generators) are given. Improved mathematical models of vibrational information-diagnostic signals are proposed, taking into account both the properties of diagnostic objects and the modes in which such equipment works. According to the results of the analysis of mathematical models of the considered information signals, a number of diagnostic signs are theoretically justified, which allows monitoring and establishing the technical condition of individual generator nodes. As illustrative examples, the use of acoustoemission and vibration diagnostic signals for the formation of training sets, which are part of a multi-level information and measurement system for monitoring and diagnostics of electrical equipment, is considered. The information base obtained at the experimental test stands of the IED of the National Academy of Sciences of Ukraine was used to form such educational groups. It is pointed out the need to take into account the influence of temperature and humidity on the assessment of diagnostic signs during monitoring and diagnostics of electrical equipment. Bible 26, fig. 8. Keywords: vibration and acoustic emission diagnostic signals, electrical equipment, monitoring and diagnostics system.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"33 48","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138601263","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
А.S. Levitskyi, I. Zaitsev, K. O. Kobzar, N.L. Sorokina
{"title":"MEASUREMENT OF EFFORT IN THE STATOR CORE TIGHTENING PRISMS OF POWERFUL TUR-BOGENERATOR USING DATA ON THE MOVEMENT OF THE COMPRESSION DISC SPRING BLOCK IN PRESSURE ACCUMULATOR","authors":"А.S. Levitskyi, I. Zaitsev, K. O. Kobzar, N.L. Sorokina","doi":"10.15407/publishing2023.66.144","DOIUrl":"https://doi.org/10.15407/publishing2023.66.144","url":null,"abstract":"The advantages and features of the use of pressure accumulators (CA) with blocks of conic springs for restoring and stabilizing the pressing pressure of the stator core of a powerful turbogenerator (TG), which are installed under the tightening nuts or instead of them on the threaded ends of the tightening prisms of the core, are described. It is shown that the measurement of the displacement of the compression disc spring in the CA makes it possible to estimate the current state of the pressing pressure. The use of a capacitive sensor of linear displacements, placed outside the CA, to control the movement of the spring block in the caseless CA is substantiated. According to the specified design parame-ters of the caseless CA and the value of the maximum stroke of the plate springs in it, a capacitive sensor with its speci-fied characteristics was developed. The method of monitoring the state of the TG stator core using the CA system with capacitive sensors on each CA and the control method with the alternate use of one disk spring travel meter are de-scribed. Ref. 14, fig. 6. Key words: powerful turbogenerator, stator core, pressure, forces in the tightening prisms, power accumulator, displacement of block compression disc spring, capacitive sensor.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"19 22","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138601718","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Gubarevich, Yu.V. Marunia, V.P. Kaban, V.Yu. Matveev
{"title":"UNIVERSAL THREE-PHASE PASSIVE MAINS CURRENT HARMONIC FILTER","authors":"V. Gubarevich, Yu.V. Marunia, V.P. Kaban, V.Yu. Matveev","doi":"10.15407/publishing2023.66.096","DOIUrl":"https://doi.org/10.15407/publishing2023.66.096","url":null,"abstract":"An analysis of well-known universal filters of current harmonics was carried out. A variant of the three-phase passive filter of network current harmonics is proposed, due to the change in its structure, the value of the voltage on the load is limited in operating modes close to idling. Mathematical modeling of such a system, which feeds a bridge rectifier with a capacitive filter and an active load with a power of 5 kW, was performed. The load characteristics and the depend-ence of the current harmonic coefficient on the change in the load power of the developed filter are given. Ref. 2, fig. 3. Keywords: current harmonic coefficient, THDI, passive filter, active filter of parallel type, hybrid filter, decentralized power supply system.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"13 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138603239","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"DETERMINATION OF THE OPTIMAL PARAMETERS OF ELECTRICAL ENERGY STORAGE AND GENERATING SOURCES IN AUTONOMOUS LOCAL ELECTRICAL SYSTEMS","authors":"M. Syvenko, O. Miroshnyk","doi":"10.15407/publishing2023.66.027","DOIUrl":"https://doi.org/10.15407/publishing2023.66.027","url":null,"abstract":"The problem of determining the optimal parameters of electric energy storage and generating sources in autonomous local power systems is presented. A detailed justification of the role of electricity storage in the presence of renewable energy sources in autonomous local power systems with a stochastic mode of operation is given. The main provisions of the used model of autonomous local electrical systems are given. The dependence of the electricity storage parameters depending on the composition of the generation was investigated. The possibility of solving the problem of determining the parameters of electricity storage devices by simulating the operation of a real system is considered. The results of the multi-criteria selection of the power and energy capacity of the electricity storage unit using economic criteria are determined. A mathematical model for determining the optimal parameters of electric energy storage for autonomous local electrical systems using mixed integer programming with optimization based on economic indicators has been developed. The dependence of the parameters of electric energy storage devices on the composition of the generation of autonomous local electrical systems has been studied. Bibl. 7, fig. 2. Keywords: local power grids, renewable energy, electricity storage, generation, autonomous sources.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"45 14","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138602371","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. V. Veremiichuk, V. Opryshko, І. Prytyskach, О. Yarmoliuk
{"title":"OPTIMIZATION OF ELECTRICITY DISTRIBUTION PROCESSES IN THE POWER SUPPLY SYSTEM OF THE ENERGY COMMUNITY","authors":"Y. V. Veremiichuk, V. Opryshko, І. Prytyskach, О. Yarmoliuk","doi":"10.15407/publishing2023.66.077","DOIUrl":"https://doi.org/10.15407/publishing2023.66.077","url":null,"abstract":"The objective of this study is to establish a methodology for the equitable distribution of loads among participants in an en-ergy community consisting of low-power renewable energy sources. This is achieved through the utilization of a modified resource allocation algorithm. The proposed approach effectively considers multiple criteria, limited initial information, and the need for flexible assignment and reprioritization of objectives and constraints. To achieve this, linguistic characteristics are employed. Furthermore, under specific conditions, the list of objective functions can be expanded to capture the diverse interests of actors in the electricity market, such as suppliers and operators. To validate the effectiveness of the proposed methodology, statistical data on the operation of renewable energy sources supplying electricity to consumers within a spe-cific region was utilized. Optimal operating modes for these sources were investigated. The focal point of this research is to develop a tool that ensures the optimal functioning of the network comprising low-power sources. To attain this, optimization criteria encompassing technical, economic, and environmental aspects were employed to derive the optimal operating modes for the renewable energy community. Bibl. 8, fig. 11, tabl. 2. Keywords: renewable energy sources, low power sources, multi-criteria decision-making, energy community, optimization.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"25 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138602574","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"OPTIMIZATION OF ELECTRICAL LOAD SCHEDULES BY AN AGGREGATOR IN LOCAL ELECTRICAL POWER SYSTEMS","authors":"H. Bielokha, V. Sychova","doi":"10.15407/publishing2023.66.084","DOIUrl":"https://doi.org/10.15407/publishing2023.66.084","url":null,"abstract":"The market operation of the electricity distribution system has gained significant expansion due to the growing use of renewable and distributed sources. This paper presents strategies for optimizing load schedules by aggregators of local systems. Optimization of load schedules is to minimize the total costs of the supplier to reduce the cost of electricity and lower prices for the consumer. In local systems, which include diesel generators, the main component that most affects the price per 1 kW is the consumption of primary fuel of diesel generators. The objective function proposed in this study minimizes the supplier's primary fuel consumption by optimally redistributing power to each generator. The basic load schedule and application of schedule optimization strategies were studied: load reduction, load transfer, increase of minimum loads, flexible load change. When using the optimal algorithm, the costs are 5-6% relative to the uniform power distribution. Ref. 8, fig. 4, table. Key words: local system, diesel-generator, load schedule, aggregator.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"18 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138602806","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"ANALYSIS OF POSSIBLE APPROACHES TO DETERMINING THE MOST RELIABLE METHOD OF ENERGY BALANCE CONSTRUCTION","authors":"P.V. Lavrynovych","doi":"10.15407/publishing2023.66.033","DOIUrl":"https://doi.org/10.15407/publishing2023.66.033","url":null,"abstract":"In the process of analyzing the methods, numerous results were obtained. On the basis of which it can be concluded that the results of calculations carried out using the method of maximum likelihood became the closest to the actual values. However, it is important to note that these results turned out to be very close to the results obtained when determining the average value of the data set. The main advantage of this definition is ease of implementation. Since the experiments were conducted on the basis of a relatively small amount of initial data, it is impossible to consider that the determination of the average value is the most appropriate for its implementation. The conclusion is suggested that there is a need to conduct an analysis based on a larger amount of initial data. And also, using other methods of finding the most reliable energy balances. The possibility of constructing maximum likelihood graphs when assessing the quality of energy balance indicators and directions of possible use of this method in tasks were considered. References 4, figure, tables 5. Key words: energy efficiency, energy balance, fuel-energy balance, maximum probability estimation method, maximum likelihood method.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"25 5","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138601693","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"DEVELOPMENT OF AN ARTIFICIAL NEURAL NETWORK FOR FORECASTING ELECTRICITY IMBALANCES IN THE IPS OF UKRAINE","authors":"V. Sychova","doi":"10.15407/publishing2023.66.058","DOIUrl":"https://doi.org/10.15407/publishing2023.66.058","url":null,"abstract":"The article presents the results of the study of an artificial neural network model of the LSTM type for short-term fore-casting of the values of positive and negative imbalances of electric energy in the IPS of Ukraine. The analysis of fore-casting results obtained with the help of hyperparameter optimization models and different window lengths and com-bining them into an ensemble of models was performed. Conducted research based on actual data of the balancing market of electric energy of Ukraine showed the effectiveness of using the specified models to solve the given problem. Ref. 10, fig. 3, tab. 3. Keywords: short-term forecasting, electricity imbalances, neural networks.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"14 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138603753","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"STUDY OF RESONANCE PHENOMENA IN THE ELECTRICAL CIRCUIT OF A 10/0.4 KV POWER TRANSFORMER WITH A CAPACITOR BATTERY","authors":"A.O. Omelʹchuk","doi":"10.15407/publishing2023.66.021","DOIUrl":"https://doi.org/10.15407/publishing2023.66.021","url":null,"abstract":"The processes in the electrical network with power transformers 10/0.4 kV with capacitor banks were investigated for the occurrence of resonance of voltages and currents at the main frequency of three-phase alternating current 50 Hz, as well as at frequencies of 150, 250, 350 and 550 Hz, caused by higher harmonic components voltage and current. Graphs showing resonance processes in specific circles are given. Bible 4, fig. 4., tab. 3. Keywords: capacitor battery, Q factor, frequency, resonance of voltages and currents.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"65 25","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138604858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"MONITORING SYSTEMS FOR MODERN POWER CABLE LINES","authors":"I. Kucheriava","doi":"10.15407/publishing2023.66.111","DOIUrl":"https://doi.org/10.15407/publishing2023.66.111","url":null,"abstract":"The overview of fiber-optic technologies for real-time monitoring of the technical condition and operational characteristics of modern power cables with cross-linked polyethylene insulation and with the fiber-optic module integrated into their structure is presented. In particular, the new intelligent means for monitoring of the temperature, load current, deformation (mechanical damages), partial discharges in the insulation, moisture penetration inside the cables and control over sheath voltage limitation are described. The topicality of using and developing the technologies of smart diagnostics for power cable lines in order to achieve the effective and safe operation of cables as well as the high reliability of networks is shown. Ref. 47, fig. 7. Key words: power cables, power cable lines, cross-linked polyethylene insulation, integrated fiber-optic modules, power networks, smart monitoring.","PeriodicalId":343330,"journal":{"name":"Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini","volume":"38 19","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138602412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}