{"title":"pCO/sub 2/, pO/sub 2/, and pH monitoring using micro-flow colorimetry","authors":"C. Cooney, B. Towe","doi":"10.1109/NEBC.1999.755794","DOIUrl":"https://doi.org/10.1109/NEBC.1999.755794","url":null,"abstract":"pCO/sub 2/, pO/sub 2/ and pH levels are optically monitored using continuous micro-flow of colorimetric indicators through hollow fiber membranes in contact with blood. Optical monitoring is achieved using LEDs and photodetectors coupled to outlet micro-bore capillary tubes. Three separate hollow fiber membranes are selected based on membrane permeability to the measurand. The sensors are exposed to blood in an extracorporeal loop using continuous flow or blood withdrawal-reinfusion.","PeriodicalId":339552,"journal":{"name":"Proceedings of the IEEE 25th Annual Northeast Bioengineering Conference (Cat. No. 99CH36355)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128252600","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Talk Aid [communication aid for autistic child]","authors":"J. Rodriguez, W. Pruehsner, J. Enderle","doi":"10.1109/NEBC.1999.755747","DOIUrl":"https://doi.org/10.1109/NEBC.1999.755747","url":null,"abstract":"Talk Aid is a communication device that produces a displayed and audio output from a user interface of input speech keys. A scalability feature allows the output of the device to grow along with its user.","PeriodicalId":339552,"journal":{"name":"Proceedings of the IEEE 25th Annual Northeast Bioengineering Conference (Cat. No. 99CH36355)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127367659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Automatic volume mesh generation applied to trabecular bone","authors":"R. Saxena, T. Keller","doi":"10.1109/NEBC.1999.755729","DOIUrl":"https://doi.org/10.1109/NEBC.1999.755729","url":null,"abstract":"Schemes for volume mesh generation involving tetrahedral and brick elements have been described. A unit cell of trabecular bone has been analyzed using both the schemes.","PeriodicalId":339552,"journal":{"name":"Proceedings of the IEEE 25th Annual Northeast Bioengineering Conference (Cat. No. 99CH36355)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127539133","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. Kline-Schoder, D. Kynor, M. Jaeger, A. Winder, C. Desilets
{"title":"Fabrication of high frequency ultrasonic transducer arrays using physical vapor deposition [for in vivo imaging]","authors":"R. Kline-Schoder, D. Kynor, M. Jaeger, A. Winder, C. Desilets","doi":"10.1109/NEBC.1999.755777","DOIUrl":"https://doi.org/10.1109/NEBC.1999.755777","url":null,"abstract":"Creare is developing microfabrication techniques to manufacture low-cost, multi-dimensional ultrasonic transducer arrays with single- and multi-layer piezoelectric elements. The fabrication approach is scaleable for manufacturing arrays in the frequency range of 10-500 MHz in dense or sparse array designs. Our approach employs the following processes: (1) high-rate physical vapor deposition (sputtering) of high-quality piezoelectric films using reactive sputtering of a metallic target and (2) photolithography and masking to provide the interlayer electrodes. This transducer technology has the potential to provide new tools to the clinician which should enable higher resolution ultrasound imaging and miniaturization of ultrasound arrays for in vivo imaging.","PeriodicalId":339552,"journal":{"name":"Proceedings of the IEEE 25th Annual Northeast Bioengineering Conference (Cat. No. 99CH36355)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131797860","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Very high frequency (VHF) ultrasonic imaging","authors":"K. Shung","doi":"10.1109/NEBC.1999.755786","DOIUrl":"https://doi.org/10.1109/NEBC.1999.755786","url":null,"abstract":"Ultrasonic imaging in the frequency range beyond 20 MHz is considered the next frontier in diagnostic ultrasound with applications in dermatology, ophthalmology and intravascular imaging. These applications and potential challenges are reviewed.","PeriodicalId":339552,"journal":{"name":"Proceedings of the IEEE 25th Annual Northeast Bioengineering Conference (Cat. No. 99CH36355)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122325095","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"T-Rider","authors":"W. Gagnon, W. Pruehsner, J. Enderle","doi":"10.1109/nebc.1999.755734","DOIUrl":"https://doi.org/10.1109/nebc.1999.755734","url":null,"abstract":"The T-Rider is a hand and foot tricycle where the rider performing a rowing motion provides propulsion. The T-Rider also has a wheel mounted generator providing electrical power to a safety strobe light.","PeriodicalId":339552,"journal":{"name":"Proceedings of the IEEE 25th Annual Northeast Bioengineering Conference (Cat. No. 99CH36355)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114167336","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Scoot Along","authors":"E. Ucol, W. Pruehsner, J. Enderle","doi":"10.1109/nebc.1999.755735","DOIUrl":"https://doi.org/10.1109/nebc.1999.755735","url":null,"abstract":"Scoot Along is a transportation device that specializes in maneuvering in small, confined areas. Ultrasonic sensors and speed adjustment controls will prevent accidents and provide safe usage. An AM/FM radio is also be mounted in the Scoot Along.","PeriodicalId":339552,"journal":{"name":"Proceedings of the IEEE 25th Annual Northeast Bioengineering Conference (Cat. No. 99CH36355)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121041897","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}