M. Saad bin Arif, Shahrine M. Avob, S. M. Yahya, Uvais Mustafa, Muhammad Ado, Z. A. Khan
{"title":"Effect of Zn-H20 Nanofluid Back-Flow Channels on the Efficiency and Electrical Power Output of a Solar PV Panel Used in Standalone PV System","authors":"M. Saad bin Arif, Shahrine M. Avob, S. M. Yahya, Uvais Mustafa, Muhammad Ado, Z. A. Khan","doi":"10.1109/APPEEC.2018.8566544","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566544","url":null,"abstract":"In this paper a solar photovoltaic based power generation system with improved panel efficiency using back flow channel is proposed. Main contribution of this work is to improve the electrical efficiency of a standalone PV system by reducing the panel temperature using Zinc-water (Zn-H20) nanofluid as a back channel fluid. Forcing nanofluid to flow through the tubes attached at the back of the panel reduces panel temperature considerably results in efficiency improvement of the panel. To analyze the performance of the proposed Zn-H20 nanofluid flow channel based PV Panel used in PV systems, MATLAB Simulink model is developed and simulation under varying conditions of temperature and irradiance for Sub-tropical region (27.8974° N, 78.0880° E) has been carried out. Results obtained with Zn-H20 nanofluid flow channel are compared with the system with air flow and without air flow channel PV panels. Proposed system using nanofluid shows efficiency improvement of 0.4-0.6% and 1-1.1 % to that with air flow channel and without air flow channel respectively. It is envisage that the proposed Panel system can be very useful for design and implementation of an efficient standalone solar PV system in sub-tropical region.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123894595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sarjiya, L. M. Putranto, M. Isnaini BS, M. A. Rosyied, Pandu Lukhyswara, F. Aditya, Eko Yudo Pramono, S. Isnandar
{"title":"Wind and Solar Power Plant Modelling and Its Impact to the Jawa-Bali Power Grid","authors":"Sarjiya, L. M. Putranto, M. Isnaini BS, M. A. Rosyied, Pandu Lukhyswara, F. Aditya, Eko Yudo Pramono, S. Isnandar","doi":"10.1109/APPEEC.2018.8566584","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566584","url":null,"abstract":"PT. PLN (Persero) has to develop renewable energy which has a minimum energy mix of 23% in 2025 and 31% in 2030. An intermittent renewable-energy power plant like wind and solar power plant, which is uncontrollable and unpredictable, will be massively penetrated. For that reason, sufficient system flexibility is necessary. The effects of intermittent wind and solar power plants in Java-Bali are conducted in this research. The intermittency of wind and solar power plant are modelled from the historical weather data in some areas with the total capacity 1,930 MW, system peak load is 25,325 MW and the total generation capacity before penetration is 35,517 MW. Then the ramping rate difference before and after penetration for every station is evaluated, which can be increases or decreases. Nevertheless, the observations in this study are the increment of maximum ramp up requirement in 30 minutes resolution in Bekasi 4 EHV station become 125.46 MW (before 65 MW) and maximum ramp down requirement in Bekasi 3 EHV station as become 90.36 MW (before 45 MW). For ensuring the ramping rate requirement, Java-Bali system has to increase the flexibility.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123210665","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Module-Based Educational Platform for Transformer Differential Digital Relay Design and Experimentation","authors":"Lodu Moses Gabriel, G. Fujita","doi":"10.1109/APPEEC.2018.8566334","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566334","url":null,"abstract":"The teaching of power system in universities and technical institutions is not in pace with the trend of power system development. In power system protection, laboratory sessions involving relays and relay design, software handling and hands-on experience are highly recommended. In this study, transducers and data acquisition instruments are assembled in a 300mm cube module and a digital relay control algorithm is designed in a LabVIEW program for practical experimentation of transformer differential digital relay in power system laboratory. Validation of the mathematical formulations by SIMULINK simulations was done first. Then LabVIEW program with an easily understandable user interface was designed. The platform was successfully tested and could trigger the contactor relay to trip when a fault occurred within the protection zone. The platform is cheap to develop and the modules can be used in other power systems experiments.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"146 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123328184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modeling of Transmission Conductor Based on Two-node Isoparametric Truss Elements and Application for Ice-shedding Analysis","authors":"Yunyun Xie, R. Tang, Linyan Huang, H. Ding","doi":"10.1109/APPEEC.2018.8566466","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566466","url":null,"abstract":"In the analysis of ice-shedding vibrations, commercial finite element software, such as ANSYS, ADINA, are mainly employed to build finite element model. However, it's difficult to build finite element model for complicated ice-shedding scenarios. Therefore, a mathematical model for the dynamic analysis of transmission conductor is built in this paper based on two-node isoparametric truss elements. Firstly, the two-node isoparametric truss element is adopted to build the static and dynamic equilibrium equations of conductor. Furthermore, the Newton- Raphson method is employed to solve static equilibrium equations of iced transmission conductors. The dynamic response of ice-shedding is obtained from the solution of dynamic equilibrium equations by the combination of Newmark and Newton- Raphson method. Finally, this method is applied to simulate ice-shedding from a full-scale span. The performance comparison between this method with the experiment and FEM software shows that the proposed method has the nearly same precision and is more flexible to analyze complicated ice-shedding scenarios.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123364721","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Damping inter-area Oscillations using Restructuring Corrective Actions","authors":"M. Setareh, M. Parniani","doi":"10.1109/APPEEC.2018.8566612","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566612","url":null,"abstract":"Nowadays, with the advent of phasor measurement units, control center operators can evaluate and monitor online the status of power systems small signal stability. In operation of power systems conditions may arise that traditional controllers cannot damp electromechanical oscillations. In these situations corrective actions can be used to suppress the oscillations. Corrective actions should be analyzed and evaluated before applying to the system. This paper investigates the effect of line switching as a corrective action on damping inter-area modes via a new algorithm which is based on calculation of first order sensitivity coefficients. The proposed method characterizes the effect of changing load flow pattern as well as topology of the network due to the line transmission switching on displacement of the inter-area mode. The 10-bus two-area test system is used to examine performance of the proposed method. The results prove accuracy and effectiveness of the method.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"23 134","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114092625","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Charles Tze Kang Kho, J. Ahmed, Y. L. Then, M. Kermadi
{"title":"Mitigating the effect of partial shading by triple-tied configuration of PV modules","authors":"Charles Tze Kang Kho, J. Ahmed, Y. L. Then, M. Kermadi","doi":"10.1109/APPEEC.2018.8566375","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566375","url":null,"abstract":"Partial shading is the phenomenon, which occurs when PV modules receive irregular irradiance on a PV array. Due to that, shaded PV modules are bypassed by diodes and significant reduction in power is experienced. To counter such problem, PV modules are connected in different configuration to provide alternative path for current to flow, so that the effect of partial shading is lessened and power attainment is improved. A comprehensive literature review suggests that several PV configurations are proposed namely simple-series (SS), parallel (P), series-parallel (SP), total-cross-tied (TCT), bridge-linked (BL) and honey-comb (HC). In this paper, a comprehensive review is presented to highlight the benefits and limitations of each scheme. To mitigate the limitation of other approaches, a new configuration named triple-tied (TT) is proposed. Several experiments are carried out using both MATLAB Simulink and hardware implementation to validate the performance of proposed configuration. Eleven different partial shading cases are used in the experiments to analyze the output characteristics. Based on the results, the proposed TT configuration outperforms other PV configurations except TCT. However, in TT wiring connections are significantly reduced compared to TCT which makes it favorable in many large-scale PV applications.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114817056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Coordinated Scheduling of Demand Response and Energy Storage to Reduce Wind Variability Costs","authors":"Xuemei Dai, Kaifeng Zhang, Jian Geng, Kun Yuan, Ying Wang, Yanmin Guo","doi":"10.1109/APPEEC.2018.8566262","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566262","url":null,"abstract":"The integration of wind energy into grids causes “variability costs” due to their variable characteristic. To reduce wind variability costs, one feasible way is to introduce demand response (DR), which can adjust the demands to more closely follow wind power outputs. On the other hand, energy storage (ES) can coordinate with demand response to accommodate the variability of wind generation. In this paper, an optimization approach considering DR and ES is proposed and various combinations of ES and DR programs are deployed to quantify reductions in the variability costs of wind power. Then the proposed optimization model is reformulated as a mixed integer linear programming (MILP) problem, which can be solved by using standard algorithms. In addition, we evaluate the performance of the proposed model by simulation studies on the modified IEEE 118-bus system. The results show that coordinated operation of ES and DR programs can effectively mitigate wind power output fluctuations and reduce the variability costs.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125706467","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Conference Programme: APPEEC 2018 - Hilton Hotel, Kota Kinabalu, Sabah","authors":"","doi":"10.1109/appeec.2018.8566482","DOIUrl":"https://doi.org/10.1109/appeec.2018.8566482","url":null,"abstract":"","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130054865","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A novel reactive power control strategy for distribution grids with large scale rooftop PV systems","authors":"Nuri Gökmen, Weihao Hu, Xiao Xu, Zhe Chen","doi":"10.1109/APPEEC.2018.8566505","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566505","url":null,"abstract":"The tendency to deploy large scale PV systems in residential areas nonstop continues all around the world. Especially, installations on single-phase lines are possessing more technical challenges to distribution system operators in terms of voltage unbalance and decreased power quality. Even though node voltages, line, and transformer loadings may be inside the safe limits for primary distribution lines due to aggregation effects, severe voltage fluctuations and equipment overloading may be seen in single-phase secondaries. To identify these problems, it is necessary to model the distribution grid from bottom to top as realistic as possible. In this study, based on such a detailed modelling approach, technical impacts of PV systems are analyzed more accurately by taking individual phases into account. Additionally, a novel reactive power control strategy is proposed benefitting from instantaneous imbalance of load and generation where their weekly changing patterns are considered to update the control parameters dynamically. It is verified that in dealing with voltage fluctuation problem, the proposed method 0.65% and 1.89% is more efficient than its traditional reactive power control method competitors, namely cosφ(P) and Q(V), respectively.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133050633","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of Induction Motor Starting on Microgrid","authors":"Di Wu, Hongbin Wu, Hao Dongt","doi":"10.1109/APPEEC.2018.8566305","DOIUrl":"https://doi.org/10.1109/APPEEC.2018.8566305","url":null,"abstract":"As the application of induction motors is more and more extensive in microgrid, it is very important to research the influence of induction motor on microgrid. A microgrid model with different distributed generations (DGs) is established in this paper. And the mathematical model of the induction motor is also presented. With the example system, the induction motor starting process is simulated in the grid-connected and islanded modes. The simulation results show the effect of induction motor starting on the transient stability of the microgrid in different modes. The specific dynamic characteristics of important parameters such as power and voltage will be changed with the induction motor starting.","PeriodicalId":337478,"journal":{"name":"2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115826966","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}