2018 ELEKTROPub Date : 2018-06-26DOI: 10.1109/ELEKTRO.2018.8398275
Yernar Zhetpissov, Azamat Kaibaldiyev, T. Do
{"title":"PI anti-windup speed control of permanent magnet synchronous motor based on feedforward compensation","authors":"Yernar Zhetpissov, Azamat Kaibaldiyev, T. Do","doi":"10.1109/ELEKTRO.2018.8398275","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398275","url":null,"abstract":"This paper designs simulation model of PI anti-windup speed controller based on a simple set-point weighting for the interior permanent-magnet synchronous motor (IPMSM). Firstly, a mathematical model of IPMSM drive system utilized in the simulation is introduced. Also, the maximum torque per ampere (MTPA) control suitable for IPMSM was employed. This controller is simple for implementation in practice and it has advantages over a conventional PI controller. The proposed anti-windup PI controller demonstrates better dynamic step changes response in speed in terms of overshoots, improved settling time, and improved robustness to parameter variations in comparison with conventional PI. The performance of proposed PI anti-windup controller with set-point weighting was compared with the conventional PI.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"87 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124811826","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-06-26DOI: 10.1109/ELEKTRO.2018.8398282
M. Pridala, M. Frivaldský, S. Ovaska
{"title":"Comparison of converters using LLC and LCCT resonant tanks","authors":"M. Pridala, M. Frivaldský, S. Ovaska","doi":"10.1109/ELEKTRO.2018.8398282","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398282","url":null,"abstract":"In this paper, the circuit topologies of LLC resonant DC-DC converter and half-bridge LCCT resonant DC-DC converter are comparatively studied for different kind of applications. A comparison of efficiency, cost and behavior of these power converters is provided. Simulation models of LLC and LCCT circuits are created using magnetic and thermal models of individual components using PLECS simulation software. Based on the circuit investigation within critical operational conditions, short-circuit and overload states are analyzed.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133143065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-06-26DOI: 10.1109/ELEKTRO.2018.8398286
Bekarys Nurtay, Bota Duisenbay, T. Do
{"title":"Direct-torque control system design using maximum torque per ampere method for interior permanent magnet synchronous motors","authors":"Bekarys Nurtay, Bota Duisenbay, T. Do","doi":"10.1109/ELEKTRO.2018.8398286","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398286","url":null,"abstract":"The paper proposes a method for controlling interior Permanent Magnet Synchronous Motor (IPMSM) drives, that combines Direct-Torque control (DTC) and Maximum Torque Per Ampere (MTPA) in a synchronously rotating (d-q) frame. It has been proven that the increase of electromagnetic torque is proportional to the increase of angle between rotor and stator flux linkages. The use of the DTC method for controlling IPMSM shows a quick and robust response with torque and flux ripples. Combined with MPTA the efficiency of the system is increased as there is no need for prior estimation of flux. Also, speed control loop with PI controller is also introduced to the system for speed regulation. Here, we introduce a simple MTPA-based DTC scheme with speed control with satisfied performance. The feasibility of the system is confirmed by Simulink model, the results of which are presented in the paper.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127576987","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-05-21DOI: 10.1109/ELEKTRO.2018.8398290
Pavel Šimon
{"title":"Possible danger of massive charging of electric vehicles without its system management","authors":"Pavel Šimon","doi":"10.1109/ELEKTRO.2018.8398290","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398290","url":null,"abstract":"This paper tries to show what consequences to grid will have when hundreds of thousands internal combustion engines cars will be replaced by electro mobiles. It describes possible charging patterns and how it would deal with immediate power capacity and total consumptions.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114649435","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-05-21DOI: 10.1109/ELEKTRO.2018.8398240
F. Muñoz, Peter Hockicko
{"title":"Electrical and acoustic properties of solid-state glass electrolytes","authors":"F. Muñoz, Peter Hockicko","doi":"10.1109/ELEKTRO.2018.8398240","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398240","url":null,"abstract":"Solid-state electrolytes have become of a notable interest in a number of applications of electrical systems for energy storage and harvesting, and all solid-state rechargeable batteries, in particular. They possess key advantages with respect to liquid electrolytes such that they are non-contaminant and do not have flammable organic compounds, thus reducing toxicity and the risk of explosions, and they may also work as an effective separator between the electrode materials. An ideal electrolyte must have a pure ionic conductivity and high chemical and thermal stability under the conditions of operation and, within the inorganic solid electrolyte materials, glasses may offer additional improvements due to their inherent nature, without grain boundaries and great variability in both chemical composition and shape. There are well-known efficient ways to improve the performance of glasses as solid electrolytes through their chemical composition, e.g. by increasing the amount of charge carriers, introducing highly polarizable anions or through the use of secondary glass former elements. However, the study of the mechanisms of conduction for each system becomes a critical issue when optimizing the properties of the researched materials.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"172 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115879416","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-05-21DOI: 10.1109/ELEKTRO.2018.8398279
M. Taraba, Juraj Adamec, M. Danko, P. Drgona
{"title":"Utilization of modern sensors in autonomous vehicles","authors":"M. Taraba, Juraj Adamec, M. Danko, P. Drgona","doi":"10.1109/ELEKTRO.2018.8398279","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398279","url":null,"abstract":"The aim of this work is the development and innovation of localization methods in interior and exterior spaces. In this work, sensors used to locate the position in autonomous vehicle systems are mentioned. Furthermore, this work deals with the fusion of data acquired from different types of sensors as well as their processing.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115625809","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-05-21DOI: 10.1109/ELEKTRO.2018.8398248
Tom Bielik, B. Adamec, V. Hottmar
{"title":"Research and practical realization of RF microstrip band-stop filter using transmission line theory","authors":"Tom Bielik, B. Adamec, V. Hottmar","doi":"10.1109/ELEKTRO.2018.8398248","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398248","url":null,"abstract":"In this paper, the analyzation and practical realization of RF microstrip band-stop filter using transmission line theory is presented. A simple measurement method has been used for determination of relative permittivity of dielectric substrate at given frequency band. The S-parameters of realized band-stop filter structure has been compared with S-parameters obtained from MATLAB and S-parameters obtained from EM simulator. The results are in good agreement.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121020353","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-05-21DOI: 10.1109/ELEKTRO.2018.8398328
S. Hannah, H. Gleskova, S. Matuska, R. Hudec
{"title":"Towards the development of a wearable temperature sensor based on a ferroelectric capacitor","authors":"S. Hannah, H. Gleskova, S. Matuska, R. Hudec","doi":"10.1109/ELEKTRO.2018.8398328","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398328","url":null,"abstract":"Response of a ferroelectric capacitor to static temperature (∼22 to 90°C) is presented. The sensor is based on ferroelectric ceramic lead zirconate titanate (PZT). The PZT sensor is a cheap, commercially available element used to provide a proof of concept for the initial investigation into using ferroelectric materials for the monitoring of static temperature. The capacitor response to temperature was measured using PZT capacitance changes recorded at 1 kHz. The capacitance was measured after the temperature had stabilised. We have found that the PZT capacitor responds linearly as a function of applied temperature, with a sensitivity ∼ 53 pF/°C. Furthermore, to provide some initial electronics capable of measuring sensor capacitance in real time, the PZT element was attached to an Arduino Uno platform. Again, the sensor continues to respond linearly to temperature with a sensitivity of 146 pF/°C. The system developed paves the way for further work to be done on using ferroelectric materials for the monitoring of static temperature changes, for applications such as human body temperature measurement using a textile-based smart-shirt setup.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134399190","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-05-21DOI: 10.1109/ELEKTRO.2018.8398276
G. Aiello, M. Cacciato, G. Scarcella, G. Scelba, F. Gennaro, N. Aiello
{"title":"RealTime emulation of a three-phase vienna rectifier with unity power factor operations","authors":"G. Aiello, M. Cacciato, G. Scarcella, G. Scelba, F. Gennaro, N. Aiello","doi":"10.1109/ELEKTRO.2018.8398276","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398276","url":null,"abstract":"In this paper a FPGA-based dynamic model of a three-phase Vienna Rectifier with unity power factor operations has been developed addressing applications as stationary chargers for electric vehicle or telecom rectifiers. Such a model has been implemented to be used in a Hardware In the Loop (HIL) system where the power converter has been replaced with an embedded system based on a FPGA board. The proposed system has been designed to test converter control algorithms in a fast and safe way. The proposed solution exploits an environment software platform with a high level abstraction, obtaining a good trade-off between accuracy and hardware resources, also allowing a faster prototyping procedure. The HIL implementation has been compared with that of the experimental rig, confirming a good agreement in terms of accuracy and dynamic behavior.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133529378","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2018 ELEKTROPub Date : 2018-05-21DOI: 10.1109/ELEKTRO.2018.8398353
K. Kierczyński, P. Żukowski, M. Šebok, M. Gutten
{"title":"Comparison of DC conductivity of the insulating oil and moisturized electrical pressboard impregnated with insulating oil","authors":"K. Kierczyński, P. Żukowski, M. Šebok, M. Gutten","doi":"10.1109/ELEKTRO.2018.8398353","DOIUrl":"https://doi.org/10.1109/ELEKTRO.2018.8398353","url":null,"abstract":"In the paper presents compares the DC conductivity of the insulating oil manufactured by Nynas and electrical pressboard Pucaro companies impregnated with the same insulating oil with different moisture contents. The study of conductivity for both materials were made for the measuring temperature in the range of 20 °C to 80 °C and measuring voltages in the range from 20 V to 1000 V. In the Arrhenius plots for both materials were been performed linear approximations of experimental results. On the basis of Arrhenius plots for the oil and the sample for the pressboard, for all measuring voltages, the value of the activation energy value of the DC conductivity and the determination coefficient R2 was determined. The value of the determination coefficient close to one indicates the high accuracy of conductivity measurements. Comparing the activation energy value of the DC conductivity for insulating oil and pressboard impregnated with the same oil, it can be concluded that the conduction in pressboard is not caused by the presence of oil in the solid component of the paper-oil insulation.","PeriodicalId":337090,"journal":{"name":"2018 ELEKTRO","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114419786","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}