{"title":"Session IV: Charge storage and transport, part b","authors":"J. West, R. L. Remke","doi":"10.1109/EIDP.1980.7683821","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683821","url":null,"abstract":"","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"85 411 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124994130","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The influence of extruded semiconducting shields on the contamination of XLPE cables","authors":"S. Sapieha, J. Crine","doi":"10.1109/EIDP.1980.7683848","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683848","url":null,"abstract":"Nuetron activation is a powerful tool to determine the average concentrations of contaminants in XLPE aged cables. It also allows the determination of radial contaminant profiles in full size cables. Semiconducting shields appear to act as sources of contamination in XLPE cables. The increase of tan δ in thermally aged cables could be due to the presence of ionic impurities; one cannot exclude, however, the possibility of oxidation effects. More work is needed to establish clearly a relation between contamination and treeing.","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126651616","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"On the unifying admittance calculation simultaneously commenting on H. Schering's conceptyon δ = 90 - |φ|","authors":"Wang Shi-liang","doi":"10.1109/EIDP.1980.7683856","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683856","url":null,"abstract":"• If problems of insulation in electrical engineering are treated strictly by unifying impedance calculations, dissipation factors must be negative values. This can be proven by the results obtained by H. Schering.1, 2 The fact that for half a century no negative dissipation factors have ever been seen shows that in the field of insulation in electrical engineering this kind of calculation has in reality been foregone.","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"110 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114332635","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Interfacial phenomena at electrode-nylon 6 at temperatures 80–120 °C","authors":"G. Sawa, S. Nakamura, M. Ieda","doi":"10.1109/EIDP.1980.7683828","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683828","url":null,"abstract":"A close examination of the step response current i(t) of nylon 6 allows one to identify the absorption and quasi-steady state conduction currents. The total absorption charge tends to saturate with rising temperature or applied field and is almost independent of electrode metals. These results can be interpreated in terms of the immigration of the fixed number of ions existing in polymer toward the counter electrode. It is also suggested from the ohmic nature of the conduction current that the accumulated ions hardly establish the space charge but are likely neutralized at the electrodes. In contrast to no difference in the absorption charge between gold and aluminum electrodes, the discharged charge with gold electrodes is greater than that with aluminum ones. It is also shown that the state of neutralized ions depends on the electric field and the period for which the absorption has been made. It is also clarified that the accumulated neutralized charges scarcely discharge at Tf, but the ionization rate is promoted at a higher temperature than Tf.","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116373484","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dielectric properties of substituted carboxylic acids","authors":"R. K. Chan","doi":"10.1109/EIDP.1980.7683859","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683859","url":null,"abstract":"The series of chloromethylacetic acids was studied because trimethylacetic acid, also called pivalic acid, had an interesting dielectric behaviour. Since the substitution of chloro- for methyl- groups had been interesting for other compounds, it was expected to show a trend of properties for this series due to the effect of the chloro groups on the carboxyl part of the molecules. Unexpectedly, the feature expected to show the most effect of the substitution, the phase II-phase I transition in pivalic acid, ceased to exist in the chloro compounds.","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126347342","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Flashover of resistor and varistor materials","authors":"J. Brainard, R. Anderson","doi":"10.1109/EIDP.1980.7683874","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683874","url":null,"abstract":"Typical voltage waveforms observed when a zinc oxide particle was stressed to breakdown are shown in Figure 1. The three different waveforms correspond to applying the voltage at three widely different rates of rise by varying the pulse amplitude. At the lowest rate, a fraction of a microsecond was required before sufficient conductivity was attained to collapse the voltage. A more abrupt collapse resulted when the sample was stressed with a faster rising voltage, although the peak voltage (considered here to be the breakdown vol tage) was increased by only a small amount. Similar results were observed with two different ohmic particles having resistivities of 110 ohm mm and 750 ohm mm which were obtained by crushing carbon-composition resistors. It should be noted that breakdown in the case of the zinc oxide sample occurred at a voltage which exceeded the expected varistor turn-on level by a factor of two or three. The important role of a gas discharge in the breakdown mechanism was verified by repeating these measurements with the sample immersed in freon gas, which raised the breakdown voltage significantly.","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132181515","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Recent investigations of models for the microwave and the far infra red absorption of dipolar fluids","authors":"J. Calderwood, W. Coffey","doi":"10.1109/EIDP.1980.7683858","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683858","url":null,"abstract":"The problem of calculating <m→e→>)is reduced to that of solving a set of simultaneous ordinary differential equations subject to the initial condition embodied in equation (24). This may be done using the numerical way of Risken and Vollmer developed for the translational problem. The advantages of this method (of reduction to ordinary differential equations) over any other is that it gives good results for any values of the parameters S.I etc so that both resonance and relaxation behaviour of the system can be predicted. Before concluding we remark one solitary situation where an exact analytical solution of the set of equations (20) may be obtained, namely the case of the free rotator where V = 0 The n dependence now vanishes and the equations reduce to equation","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"323-325 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130877040","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Theory of dielectric relaxation in blocking contact MIM structures","authors":"H. M. Gupta","doi":"10.1109/EIDP.1980.7683830","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683830","url":null,"abstract":"Metal-insulator or metal-amorphous semiconductor blocking contacts are important because of their potential solar cell applications.1, 2 However, these structures are still not well understood even for crystalline materials,3 while the case of amorphous material is even more uncertain and poorly understood. In most cases, only steady state characteristics of these structures are studied. This can provide limited information. Characteristics before the current becomes constant can provide information on a wider scale, and thus assumptions on metal-insulator structure can be judged more critically. The theory of dielectric relaxation for MIM structures was first formulated by Simmons and Taylor.4 As recently pointed out by us,5 this theory can explain the experimental results only qualitatively. Thus the correctness of the assumptions of the theory and the conclusions drawn from it are doubtful. We feel that it is still necessary to know the charge conduction mechanism in such structures. The object of the present paper is to discuss the theory of isothermal dielectric relaxation in blocking contact metal-insula tor-metal structures considering various possible assumptions.","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125398768","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Insulating coatings on electrodes in transformer oil","authors":"I. Chalmers, O. Farish, R. Greenshields","doi":"10.1109/EIDP.1980.7683881","DOIUrl":"https://doi.org/10.1109/EIDP.1980.7683881","url":null,"abstract":"The work has demonstrated that oil purity is undoubtedly the most important single variable in determining the insulation strength with both coated and uncoated electrodes. The rapid deterioration in strength observed in newly purified oil is believed to be due to contamination by atmospheric moisture and is therefore unlikely to be experienced to the same degree in closed systems.","PeriodicalId":337053,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1980","volume":"140 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1980-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131463100","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}