{"title":"On the ambiguity of Quality of Service and Quality of Experience requirements for eHealth services","authors":"M. Ullah, M. Fiedler, K. Wac","doi":"10.1109/ISMICT.2012.6203030","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203030","url":null,"abstract":"The use of end-to-end communication systems as a medium of delivery for electronic healthcare (eHealth) services is considered to be uncertain, with respect to its reliability leading to hesitation in acceptance of such services. There exist different influential dimensions that pose stringent requirements on end-to-end communication systems, influence user perception and might hinder user acceptance. The later is referred to as Quality of Experience (QoE), which among others depends on the Quality of Service (QoS) of the end-to-end communication system. QoE is considered as a key component determining user acceptance. This paper identifies and analyzes characteristics of a set of eHealth services and the influential dimensions resulting in different QoS requirements and potential impact of QoS on QoE. It highlights the role of QoS and QoE for acceptance of these services. The issue of non-uniform views regarding QoS parameter specifications and related requirements, clinically acceptable thresholds and their qualitative representation in eHealth literature is reviewed and presented.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122354026","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance of UWB receivers using IEEE802.15.4a's minimum burst lengths","authors":"M. Hamalainen, V. Niemela, J. Iinatti, R. Kohno","doi":"10.1109/ISMICT.2012.6203046","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203046","url":null,"abstract":"In this paper, the performances of different kinds of IEEE802.15.4a receivers, which are suitable for the modulation methods and their combinations defined by the standard, are compared using two dissimilar channel models for wireless body area networks. The reference channel model is the one defined by the IEEE802.15.6 standardization group, and the other one is based on the channel measurements carried out by the Centre for Wireless Communications, University of Oulu, Finland. Both channel models are targeted for wireless body area network applications. The studied information signal structure follows the IEEE802.15.4a standard, having two pulses in a burst, and either two or eight burst positions per symbol quarter. This signal structure is non-mandatory according to the standard. Following the standard, the mode with two pulses per burst and two hopping positions gives the shortest symbol duration. Because this symbol duration is shorter than a delay spread of the channel, the signal is vulnerable for severe inter-symbol interference. Our main interest is to compare the performances of this specific signal structure, with different receiver structures from the standard, and compare the results to the corresponding results of the mandatory mode signaling presented in our earlier publications.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123631711","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"BAN MAC protocol for optimization the ratio between CAP and CFP","authors":"Y. Fujiura, C. Sugimoto, R. Kohno","doi":"10.1109/ISMICT.2012.6203025","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203025","url":null,"abstract":"Recently, a micro or nano size wireless telecommunications device such as a wireless implant capsule endoscope has been researched and developed. These wearable and implanted wireless devices are quite useful to remotely monitor various vital information, for example ECG, EEG, etc. And we use manipulators for medical treatment. In order to connect several medical sensors and actuators in and on human body, wireless body area network (BAN) has been developed. However, wireless radio communications in BAN may occur a large variance of transmission delay due to complicated radio propagation in and on body. In addition, a lot of packets are coming with contention against each other. The large variance of delay may cause a serious problem in remote medical treatment. Therefore medical packets must be guaranteed about the delay and the authenticity. In particular, emergency access packets should be guaranteed a largest delay within a permissible range. On another front, communication efficiency of non-medical packets has to be guaranteed as much as possible. A MAC protocol using hybrid structure of super frame in IEEE802.15.6 has been proposed. However, a ratio between CFP and CAP in a super frame has not been determined in the standard yet. This paper investigates how to determine the ratio according to traffic of medical and non-medical packets. After calculating the best length of CFP by the medical traffic, non-medical information is allocated in CFP as much as possible. In so doing, the total throughput is improved after securing the delay of medical information. Moreover as for traffic monitoring, we proposed the slotted aloha plotocpl for using the different transmition timing as to the priority of packets. The utility of the method was evaluated by computer simulation. On the proposed method, throughput of medical packets is nearly equal to being allocated CFP to upper limit, and non-medical throughput is better than fixed slots method. Therefore, total throughput is improved. And the accuracy of traffic estimation is good performance for using proposed determining the ratio of CAP and CFP slots.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"103 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132249837","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Activity classification using a state transition diagram and activity levels","authors":"A. Sorvala, E. Alasaarela, H. Sorvoja, R. Myllyla","doi":"10.1109/ISMICT.2012.6203031","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203031","url":null,"abstract":"Wireless health monitoring systems are suggested for use in the health care of the elderly to enable independent but secure living for as long as possible. Activity monitoring is highly valued by welfare and health personnel because it gives an overview of the well-being of the elderly. In this paper, a state transition diagram based activity classification MATLAB-algorithm is described. The state transition diagram takes consideration of the reasonable sequential states. The system distinguishes between different states and activity levels with the help of a single waist worn measurement unit consisting of a tri-axial accelerometer and a tri-axial gyroscope. The allowable states are stand, sit, lie, walk, and fall. Every second of data is classified into one of the previous states, but also into one of the four possible activity levels: passivity, light activity, activity, and intense activity. The performance of the state classification is tested with the data collected in a home environment. The sensitivity and specificity values for the state transitions are in the range of 80-100%. The classifier detects longer continuous periods in the same state with a minimum probability of 85.7%.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130013065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Sarestoniemi, T. Tuovinen, M. Hamalainen, K. Y. Yazdandoost, E. Kaivanto, J. Iinatti
{"title":"Applicability of Finite Integration Technique for the modelling of UWB channel characterization","authors":"M. Sarestoniemi, T. Tuovinen, M. Hamalainen, K. Y. Yazdandoost, E. Kaivanto, J. Iinatti","doi":"10.1109/ISMICT.2012.6203045","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203045","url":null,"abstract":"The objective of this paper is to verify applicability of Finite Integration Technique (FIT) based simulations in the modeling of Ultra Wideband (UWB) radio channel. A printed planar UWB monopole antenna, designed for Wireless Body Area Networks' (WBAN) on-body and off-body communications, is used in the experiments. The validation of the FIT-method is performed by comparing the simulation and measurement results in free space. The analysis was performed both in frequency and time domains. Furthermore, the channel behavior was explained with UWB antenna characteristics. The simulated and measured results are shown to have excellent correspondence both in frequency and time domain. All antenna simulations are done with Computer Simulation Technology (CST) Microwave Studio (MWS) software.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131623264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power efficient wakeup mechanisms for wireless body area networks","authors":"K. Kwak, M. Al Ameen, J. Huh","doi":"10.1109/ISMICT.2012.6203047","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203047","url":null,"abstract":"The use of wireless sensors in healthcare has given rise to a new field called wireless body area networks (BAN). A sensor node used in a BAN has limited resources in terms of processing power, battery and memory. It is of outmost importance that the use of power is controlled in such a way that these nodes work longer. Media access control (MAC) layer directly involves with the transceiver which is the major source of power use. A common practice in MAC protocols to save power is to let the nodes sleep (switch off major components) whenever there is no need for communication. However, the major difference between them is the way the nodes wakeup to communicate. The wakeup mechanism is critical for network performance metrics such as power efficiency, delay, throughput and lifetime. Suitable wakeup mechanism can significantly improve the performance of MAC protocols for BAN. In this paper, we study the wakeup mechanisms in MAC protocol for BAN.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"173 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121783941","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"M2M communications for e-health: Standards, enabling technologies, and research challenges","authors":"Z. Fan, S. Tan","doi":"10.1109/ISMICT.2012.6203032","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203032","url":null,"abstract":"In this paper, we discuss the application of machine-to-machine (M2M) communications to healthcare. We analyze some of the enabling technologies of M2M and present an overview of the challenges, research opportunities, and standardization activities of this exciting area.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"343 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133809669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study on position estimation of implanted devices by using signal processing for UWB Ground Penetrating Radar","authors":"Y. Kazumoto, C. Sugimoto, R. Kohno","doi":"10.1109/ISMICT.2012.6203041","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203041","url":null,"abstract":"Ground Penetrating Radar (GPR) is a method for estimation of underground structures by sending and receiving electromagnetic. With Ultra Wideband (UWB) signal, GPR is expected to improve resolution for detection of objects in underground. But there are problems that attenuation of waves from deep objects and confusion of waves from different objects. We propose a signal processing for UWB GPR to improve detection accuracy by applying interference cancellation technique for wireless communication. To obtain gains, we use a long transmitting signal with PN codes remain in low instantaneous power. Then estimating and cancelling reflect waves from received signals, we detect objects recursively. Position estimation of medical implanted devices can be also improved by using the technique. With comparing GPR and medical devices, we study a signal processing for position estimation for objects in dielectric substances.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133150665","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High accuracy tag tracking system based on TDOA in medical network","authors":"K. Enda, M. Kabir, F. Ono, R. Kohno","doi":"10.1109/ISMICT.2012.6203053","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203053","url":null,"abstract":"Recently, several researches consider how to improve estimation accuracy in a time difference of arrival (TDOA) localization system using UWB in a non-line-of-sight (NLOS) environment for medical network. This method consists of step-by-step compensation on the basis of two approaches considering a reference position that is estimated from data affected by NLOS delay. The first consideration consists of determining NLOS delays for each node, performing compensation to alleviate the effect on line of sight (LOS) nodes through a step-by-step compensation for the NLOS delay. The second consideration consists of compensating the effect of NLOS delay on the position determined on the basis of node distribution and geometrical relations of the estimated positions. Using these considerations, we show that the proposed method outperforms the conventional method in terms of estimation accuracy. Finally, the tracking experiment using the prototype is performed, and we show that proposed method exhibits better accuracy than conventional method.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115627792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sample-wise differential detection of Impulse-Radio Ultra-Wideband Pulse Position modulated symbols","authors":"I. Dotlic, R. Miura","doi":"10.1109/ISMICT.2012.6203036","DOIUrl":"https://doi.org/10.1109/ISMICT.2012.6203036","url":null,"abstract":"The paper describes technique for differential detection of Impulse Radio Ultra-Wideband (IR-UWB) Pulse Position Modulated (PPM) symbols. An expression for probability of error in noise is derived. The numerical results show the method's performance enhancement compared to the energy detection in noise and considerable performance enhancement in multiuser interference. The method is applicable to the mandatory mode of the IEEE 802.15.6 Body Area Network (BAN) IR-UWB standard.","PeriodicalId":336801,"journal":{"name":"2012 6th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116061339","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}