Energy and Built Environment最新文献

筛选
英文 中文
Real time and Modelled Performance Assessment and Validation studies of PV modules operating in varied climatic zones. 对在不同气候区运行的光伏组件进行实时和模型性能评估与验证研究。
Energy and Built Environment Pub Date : 2023-11-01 DOI: 10.1016/j.enbenv.2023.11.009
Yogesh Kumar Singh, Santosh Dubey, Pramod Rajput, K. Y. Singh, K. Pandey
{"title":"Real time and Modelled Performance Assessment and Validation studies of PV modules operating in varied climatic zones.","authors":"Yogesh Kumar Singh, Santosh Dubey, Pramod Rajput, K. Y. Singh, K. Pandey","doi":"10.1016/j.enbenv.2023.11.009","DOIUrl":"https://doi.org/10.1016/j.enbenv.2023.11.009","url":null,"abstract":"","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"2 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139301380","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Performance evaluation of a rotary dehumidifier with molecular sieve desiccant using coupled regeneration mode: Experimental investigation 旋转除湿机与分子筛干燥剂耦合再生性能评价的实验研究
Energy and Built Environment Pub Date : 2023-10-29 DOI: 10.1016/j.enbenv.2023.10.008
Hussam Bin Mehare, Taliv Hussain, Mohd Aqib Zia, Saif Saleem
{"title":"Performance evaluation of a rotary dehumidifier with molecular sieve desiccant using coupled regeneration mode: Experimental investigation","authors":"Hussam Bin Mehare,&nbsp;Taliv Hussain,&nbsp;Mohd Aqib Zia,&nbsp;Saif Saleem","doi":"10.1016/j.enbenv.2023.10.008","DOIUrl":"10.1016/j.enbenv.2023.10.008","url":null,"abstract":"<div><div>The increasing demand for energy-efficient and environmentally friendly air conditioning systems has led to the development of innovative technologies such as desiccant cooling systems. This study presents a comprehensive experimental analysis of the dehumidification and thermal performance of a rotary dehumidifier with molecular sieve desiccant designed to effectively remove moisture from the air by utilizing coupled regeneration mode (complete waste heat liberated out of condenser and electric rod heat). Various experiments were conducted to investigate different performance parameters including moisture removed from air by adsorption, moisture added to air by regeneration, dehumidification effectiveness, regeneration effectiveness, moisture removal capacity (MRC), regeneration rate (RR) at different process air inlet temperatures ranging (28–34 °C) and at different regeneration air inlet temperatures ranging (55–62 °C). These experiments were conducted at same air velocity for both adsorption and regeneration segments of rotary solid desiccant wheel using molecular sieve. The results showed that the performance of the desiccant wheel was affected by inlet temperature and humidity ratio for adsorption and regeneration segments. The findings emphasize the system's ability to provide efficient dehumidification and cooling while simultaneously promoting sustainable energy practices. Moreover, the waste heat recovery system significantly contributes to the overall efficiency improvement of the rotary dehumidifier with molecular sieve desiccant, making it an environmentally friendly alternative to conventional air conditioning technologies.</div></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 2","pages":"Pages 219-229"},"PeriodicalIF":0.0,"publicationDate":"2023-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136127967","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comprehensive evaluation of spray arrangement strategies for spray-local exhaust ventilation 全面评估喷雾局部排气通风的喷雾布置策略
Energy and Built Environment Pub Date : 2023-10-26 DOI: 10.1016/j.enbenv.2023.10.005
{"title":"Comprehensive evaluation of spray arrangement strategies for spray-local exhaust ventilation","authors":"","doi":"10.1016/j.enbenv.2023.10.005","DOIUrl":"10.1016/j.enbenv.2023.10.005","url":null,"abstract":"<div><p>A well-designed spray system, which is located near the source of high-temperature smoke, can improve the capture efficiency of traditional local exhaust ventilation (LEV). However, there is currently no comprehensive evaluation index that clearly reflects the performance of spray-local exhaust ventilation (SLEV), making it challenging to optimize the spray arrangement. The two-phase flow fields in the SLEV and LEV were compared to evaluate the impact of spray on smoke control. The effects of spray arrangement parameters, such as spray position, spacing, initial droplet size, and angle, on the performance of the SLEV system were further evaluated using current evaluation indicators. Based on this, we developed a comprehensive evaluation model for SLEV using the AHP-entropy combination weighting method. The results revealed that the decrease in smoke control with an increase in rolling speed is primarily caused by a reduction in spray control in the central region of the smoke. When the spray flow rate is 0.0028 kg/s and the velocity is 30 m/s, the primary factor that improves ventilation performance is the downward drag force exerted by the spray on smoke, rather than the cooling effect. The comprehensive model was developed using weights of 0.45, 0.34, and 0.21 for the three evaluation indicators: capture efficiency, high-quality concentration field ratio, and spatial droplet size. The model showed good reliability based on the results of the smoke concentration analysis. The results of this study are expected to guide the design, implementation, and evaluation of SLEV systems.</p></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 1","pages":"Pages 173-186"},"PeriodicalIF":0.0,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666123323001010/pdfft?md5=f3af9cfac73babcfdb2937ed3399b6e9&pid=1-s2.0-S2666123323001010-main.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136093215","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Experimental study of air source heat pump water heater: Energy, exergy, and entransy analysis 空气源热泵热水器的实验研究:能量、用能和能量分析。
Energy and Built Environment Pub Date : 2023-10-26 DOI: 10.1016/j.enbenv.2023.10.006
Fang Ruan, Saisai Xu, Dingye Qin, Shun Li, Pengxu Chen
{"title":"Experimental study of air source heat pump water heater: Energy, exergy, and entransy analysis","authors":"Fang Ruan,&nbsp;Saisai Xu,&nbsp;Dingye Qin,&nbsp;Shun Li,&nbsp;Pengxu Chen","doi":"10.1016/j.enbenv.2023.10.006","DOIUrl":"10.1016/j.enbenv.2023.10.006","url":null,"abstract":"<div><div>With the continuous progress of urbanization, building energy consumption is increasing dramatically. At present, energy consumption caused by air conditioning accounts for a half in typical building energy consumption in China. Using exergy and entransy analysis, this paper experimentally studies the thermal performance of an air source heat pump water heater and its components under different meteorological conditions. This paper, for the first time, introduces the dimensionless number of entransy dissipation ratio (EDR), namely the percentage of a component's entransy dissipation into the entire system. The findings indicate that with the increase in air temperature, the heat production, the EDR of condenser and evaporator, and the exergy efficiency of condenser and compressor increase while the exergic efficiency of evaporator and throttle valve decrease. In the case of increased air flow rate, the heat production and exergy destruction of water heater as well as the EDR of evaporator are enhanced, while the exergy efficiency of evaporator, compressor and throttle and the EDR of condenser decrease, with the exergy efficiency of the throttle remaining the highest. The irreversibility rates of components are affected by change in the relative humidity of air, which is specified as follows: The percentage range of irreversibility rates for compressor, condenser, throttle and evaporator is 11.5–16 %, 37–45 %, 6.8–11.5 % and 32–41 %, respectively.</div></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 2","pages":"Pages 187-200"},"PeriodicalIF":0.0,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136161227","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study and optimization on heat storage and release characteristics of a cascaded sensible-latent heat composite energy storage heat sink 层叠式显热-惰性热复合储能散热器的储热和释热特性研究与优化
Energy and Built Environment Pub Date : 2023-10-25 DOI: 10.1016/j.enbenv.2023.10.004
{"title":"Study and optimization on heat storage and release characteristics of a cascaded sensible-latent heat composite energy storage heat sink","authors":"","doi":"10.1016/j.enbenv.2023.10.004","DOIUrl":"10.1016/j.enbenv.2023.10.004","url":null,"abstract":"<div><p>The energy storage is an effective solution for the current imbalance between energy supply and demand. In particular, the cascaded storage method can enhance the heat exchange temperature difference and heat storage efficiency. Previous research mainly focused on the combination of different phase change materials, while there was rare research on efficient cascaded conversion pathways for electrothermal direct conversion coupled thermal storage devices. This study investigated the influence of sensible and latent heat storage materials on the thermal performance, and identified the optimal volume ratios and materials types. When the volume share of Mg-Al:PW-EG=1:1, the heat storage performance was the optimal with a quantity/efficiency of heat stored as 7328.7 kJ/97.3 %, leading to an increase of 458.5 kJ/6.6 % than the sensible heat storage condition (Mg-Al:PW-EG=1:0) and 630.18 kJ/8.5 % than the latent heat storage condition (Mg-Al:PW-EG<strong>=</strong>0:1). When the melting point and latent heat of phase change materials increased from 68.9∼79.1 °C and 224.8 kJ/kg to 118.0 °C and 344.9 kJ/kg respectively, the heat storage temperature rose by 162.7 °C, quantity of heat stored rose by 7535.5 kJ. While materials with large subcooling were not recommended for short-term heat storage, as approximately 25.6 % (3309.3 kJ) of stored heat and 22.4 % (2505.2 kJ) of exergy were wasted when the subcooling degree was 70 °C. The findings provided solutions to support the synergistic enhancement of heat storage/release performance of the composite energy storage heat sink.</p></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 1","pages":"Pages 161-172"},"PeriodicalIF":0.0,"publicationDate":"2023-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666123323001009/pdfft?md5=dc1d612b2a4f3b1fdf210a9f84a60dbd&pid=1-s2.0-S2666123323001009-main.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136093765","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative analysis of insulation strategies for improving thermal performance of wall to parkade suspended slab 改善墙壁与停机坪悬挂板热工性能的隔热策略比较分析
Energy and Built Environment Pub Date : 2023-10-21 DOI: 10.1016/j.enbenv.2023.10.003
{"title":"Comparative analysis of insulation strategies for improving thermal performance of wall to parkade suspended slab","authors":"","doi":"10.1016/j.enbenv.2023.10.003","DOIUrl":"10.1016/j.enbenv.2023.10.003","url":null,"abstract":"<div><p>This article focuses on the thermal bridging issues associated with interface of parkade concrete suspended slab to base of wall. The study aims to determine the optimal length and thickness of insulation at the top and underside of the suspended slab to minimize heat loss. The thermal performance of wall to parkade suspended slab is investigated, for both wood frame and steel stud constructions. Various insulation configurations are proposed and evaluated, including different lengths and thicknesses of extruded polystyrene foam (XPS) and Fiberglass spray insulations. The thermal performance calculations are conducted using steady-state heat transfer analysis. A finite-element based software is utilized for the simulations. The study provides a detailed methodology for analyzing the thermal performance of building envelope details, considering different insulation configurations. The results of the simulations are presented as Thermal Resistance Values (R-Values) and Linear Thermal Resistance Values (PSI-Values), allowing for a comparison of the thermal efficiency of different insulation configurations. The results show that utilizing the optimal insulation configuration can lead to up to 80 % enhancement in the thermal efficiency of the assembly. The findings serve as a guideline and aim to assist building designers in improving the thermal performance of concrete suspended slabs.</p></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 1","pages":"Pages 147-160"},"PeriodicalIF":0.0,"publicationDate":"2023-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666123323000995/pdfft?md5=06097579ac2f12710c66972affba3f7d&pid=1-s2.0-S2666123323000995-main.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136009818","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study of occupant behaviour to improve thermal comfort conditions by arranging furniture in student hostel rooms 通过布置学生宿舍家具改善热舒适条件的居住者行为研究
Energy and Built Environment Pub Date : 2023-10-18 DOI: 10.1016/j.enbenv.2023.10.002
{"title":"Study of occupant behaviour to improve thermal comfort conditions by arranging furniture in student hostel rooms","authors":"","doi":"10.1016/j.enbenv.2023.10.002","DOIUrl":"10.1016/j.enbenv.2023.10.002","url":null,"abstract":"<div><p>Research on thermal comfort has revealed various adaptive behaviours in a hostel room, such as changing clothing, use of windows, doors, and ceiling fans. Hostel rooms are used for various activities and are typically furnished with a wardrobe, bed, study table, and chair. Recent studies indicate that ceiling fan fixed at the centre of the room may not provide adequate air velocity for different activities occurring in different parts of a room. Although students generally arrange furniture based on their preferences and room geometry, the influence of fan-induced air on furniture layout to improve thermal comfort is yet to be established. In this context, this study investigates spatial adaptation and identifies the factors affecting furniture layout preferences in hostel rooms. In a yearlong study, patterns of furniture layout were observed in twenty-one naturally ventilated hostel buildings to find their relationship with environmental and non-environmental factors. A total of 1665 observation data was collected from single, double, and triple occupancy rooms. Influence of various factors on arranging the furniture was identified through a questionnaire survey. Throughout the survey, outdoor temperature varied between 23 and 41 °C and outdoor relative humidity varied between 32.3 % and 97.5 %. The spatial arrangement of furniture was evaluated against fan location. Results indicate that fan location and indoor temperature significantly influence the furniture arrangement. A logistic regression equation was developed to evaluate the trigger temperature when students began moving furniture towards ceiling fan. In a single occupancy room, above 34.2 °C, the probability of moving the bed towards the fan was found to be maximum. In single and double occupancy rooms, students move the bed near the ceiling fan predominantly during night-time to get sufficient air movement. A cautious design of furniture layout and adding a personalised fan for various activities may improve the thermal comfort in hostel rooms.</p></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 1","pages":"Pages 136-146"},"PeriodicalIF":0.0,"publicationDate":"2023-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666123323000983/pdfft?md5=fe79244ba65795548b55b751197b33df&pid=1-s2.0-S2666123323000983-main.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135850375","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Critical review of Air-Based PVT technology and its integration to building energy systems 对气基光电转换技术及其与建筑能源系统集成的严格审查
Energy and Built Environment Pub Date : 2023-10-11 DOI: 10.1016/j.enbenv.2023.10.001
{"title":"Critical review of Air-Based PVT technology and its integration to building energy systems","authors":"","doi":"10.1016/j.enbenv.2023.10.001","DOIUrl":"10.1016/j.enbenv.2023.10.001","url":null,"abstract":"<div><p>Climate crisis mitigation roadmaps, policies and directives have increasingly declared that a key element for the facilitation of sustainable urban development is on-site decentralized renewable energy generation. A technology with enhanced capabilities, able of promoting the integration of renewable energy into buildings, for energy independent and resilient communities, is Photovoltaic Thermal (PVT) systems. Ongoing research has potential yet displays a lack in unified methodology. This limits its influence on future decision-making in building and city planning levels. In this investigation, the often overlooked air-based PVT technology is put on the spotlight and their suitability for integration with energy systems of buildings is assessed. The aim of this study is to highlight vital performance and integration roadblocks in PVT research and offer suggestions for overcoming them. The methodology of reviewed literature is examined in detail with the goal of contributing to a unified approach for more impactful research.</p></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 1","pages":"Pages 121-135"},"PeriodicalIF":0.0,"publicationDate":"2023-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666123323000910/pdfft?md5=ead4de27c5286ecbb80661b39afefb4b&pid=1-s2.0-S2666123323000910-main.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135661533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Hourly energy consumption characteristics of metro rail transit: Train traction versus station operation 地铁轨道交通小时能耗特征:列车牵引与车站运行
Energy and Built Environment Pub Date : 2023-10-01 DOI: 10.1016/j.enbenv.2022.05.001
Bowen Guan , Xiaohua Liu , Tao Zhang , Xinke Wang
{"title":"Hourly energy consumption characteristics of metro rail transit: Train traction versus station operation","authors":"Bowen Guan ,&nbsp;Xiaohua Liu ,&nbsp;Tao Zhang ,&nbsp;Xinke Wang","doi":"10.1016/j.enbenv.2022.05.001","DOIUrl":"10.1016/j.enbenv.2022.05.001","url":null,"abstract":"<div><p>The electricity consumption of the urban metro system can be mainly divided into the following two categories: the electricity consumption for train traction (<em>E</em><sub>t</sub>) and the electricity consumption for station operation (<em>E</em><sub>s</sub>). Although understanding the hourly fluctuation characteristics of <em>E</em><sub>t</sub> and <em>E</em><sub>s</sub> contributes to renewable energy integration and achieving carbon emission reduction of the metro system, the hourly fluctuation characteristics have been poorly reported in the literature. Thus, a typical underground non-transfer metro station of a city's metro system in the North China Plain is selected in this study, and <em>E</em><sub>t</sub> and <em>E</em><sub>s</sub> were monitored to portray their hourly fluctuation characteristics. Results reveal that the hourly <em>E</em><sub>t</sub> shows a significant intraday “U” shape on weekdays, indicating two symmetric peaks in morning and evening rush hours. While the hourly <em>E</em><sub>s</sub> shows an intraday “flat” shape, indicating it is nearly free from the effect of rush hour. Moreover, it is statistically proved that the train frequency is the core influencing factor resulting in the intraday fluctuation of hourly <em>E</em><sub>t</sub>. In the case study, when the train frequency increases from the mean (20 trains per hour) to maximum (32 trains per hour), the hourly <em>E</em><sub>t</sub> will increase by 53.4%.</p></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"4 5","pages":"Pages 568-575"},"PeriodicalIF":0.0,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46298662","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Design of a stearic acid/boron nitride/expanded graphite multifiller synergistic composite phase change material for thermal energy storage 硬脂酸/氮化硼/膨胀石墨复合填料协同相变储热材料的设计
Energy and Built Environment Pub Date : 2023-10-01 DOI: 10.1016/j.enbenv.2022.04.004
Ci Ao , Suying Yan , Long Zhao , Xiaoyan Zhao , Yuting Wu
{"title":"Design of a stearic acid/boron nitride/expanded graphite multifiller synergistic composite phase change material for thermal energy storage","authors":"Ci Ao ,&nbsp;Suying Yan ,&nbsp;Long Zhao ,&nbsp;Xiaoyan Zhao ,&nbsp;Yuting Wu","doi":"10.1016/j.enbenv.2022.04.004","DOIUrl":"https://doi.org/10.1016/j.enbenv.2022.04.004","url":null,"abstract":"<div><p>In order to solve the problems of low thermal conductivity and easy liquid leakage of a stearic acid (SA), the composite phase change material(PCM) was prepared by adding boron nitride (BN) and expanded graphite (EG) to melted SA, and its thermal conductivity, crystal structure, chemical stability, thermal stability, cycle stability, leakage characteristics, heat storage/release characteristics, and temperature response characteristics were characterized. The results showed that the addition of BN and EG significantly improved the thermal conductivity of the material, and they efficiently adsorbed melted SA. The maximum load of SA was 76 wt. % and there was almost no liquid leakage. Moreover, the melting enthalpy and temperature were 154.20 J • g <sup>− 1</sup> and 67.85°C, respectively. Compared with pure SA, the SA/BN/EG composite showed a lower melting temperature and a higher freezing temperature. In addition, when the mass fraction of BN and EG was 12 wt. %, the thermal conductivity of the composite was 6.349 W • m<sup>−1</sup> • K<sup>−1</sup>, which was 18.619 times that of SA. More importantly, the composite showed good stability for 50 cycles of heating and cooling, and the SA / BN / EG-12 hardly decomposes below 200°C, which implies that the working performance of the composite PCM is relatively stable within the temperature range of 100°C. Therefore, the composite can exhibit excellent thermal stability in the field of building heating.</p></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"4 5","pages":"Pages 557-567"},"PeriodicalIF":0.0,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49742445","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信