R&D Journal最新文献

筛选
英文 中文
Design of a Test Setup for Measuring all Load Components Acting on Tillage and Planting Implements 一种用于测量所有作用在耕作和种植工具上的载荷分量的测试装置的设计
R&D Journal Pub Date : 2022-06-01 DOI: 10.17159/2309-8988/2022/v38a2
J. van Santen, C. Coetzee
{"title":"Design of a Test Setup for Measuring all Load Components Acting on Tillage and Planting Implements","authors":"J. van Santen, C. Coetzee","doi":"10.17159/2309-8988/2022/v38a2","DOIUrl":"https://doi.org/10.17159/2309-8988/2022/v38a2","url":null,"abstract":"This project entailed the design, manufacture, and testing of a test setup with the ability to measure all load components acting on tillage and planting implements. In future, data obtained with the test setup can be used to perform accurate design calculations, as input into finite element simulations, and to perform accurate fatigue analysis. The design of implements can therefore be improved to better withstand the loads under various operational conditions and to minimise fatigue cracking. Laboratory controlled testing, and subsequent field tests, proved that the designed test setup was able to isolate and accurately measure each of the three orthogonal load components, as well as the main moment. It was further shown that the remaining two moments could be accurately calculated using the measured load components and fixed geometric lengths. The conclusion was drawn, based on field tests, that an increase in speed with the tine ripper had no significant effect on the mean load. Further, an increase in the working depth, resulted in an increase in the load, especially in the draught and vertical directions. Finally, it was shown that a decrease in turning radius (a tighter turn), resulted in an increase in the lateral force component.","PeriodicalId":331389,"journal":{"name":"R&D Journal","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116322443","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Pressure Recovery Discharge Configurations for an Induced Draught Axial Flow Fan 诱导通风轴流风机的压力恢复排放结构
R&D Journal Pub Date : 2022-06-01 DOI: 10.17159/2309-8988/2022/v38a1
G. Bekker, C. Meyer, S. J. van der Spuy
{"title":"Pressure Recovery Discharge Configurations for an Induced Draught Axial Flow Fan","authors":"G. Bekker, C. Meyer, S. J. van der Spuy","doi":"10.17159/2309-8988/2022/v38a1","DOIUrl":"https://doi.org/10.17159/2309-8988/2022/v38a1","url":null,"abstract":"This study investigates the potential gains in operating volume flow rate and static efficiency of an induced draught axial flow fan system. These gains are achieved through pressure recovery, i.e. the conversion of dynamic pressure at the fan exit into static pressure. Pressure recovery is achieved using downstream diffusers, stator blade rows, and combinations of these. Three different diffuser lengths are considered. Of the shortest diffusers, a conical diffuser increases the operating volume flow rate by 3.2 % and the fan static efficiency by 9.8 % (absolute). A longer conical diffuser increases it by 3.9 % and 11.9 %, respectively. Of the longest diffusers, an annular diffuser increases the flow rate by 5.5 % and the fan static efficiency by 16.8 %.","PeriodicalId":331389,"journal":{"name":"R&D Journal","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123939031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An Android Application-based Surface Oust Classifier 基于Android应用程序的表面淘汰分类器
R&D Journal Pub Date : 1900-01-01 DOI: 10.17159/2309-8988/2019/v39a1
P. Dabee, B. Rajkumarsingh, Y. Beeharry
{"title":"An Android Application-based Surface Oust Classifier","authors":"P. Dabee, B. Rajkumarsingh, Y. Beeharry","doi":"10.17159/2309-8988/2019/v39a1","DOIUrl":"https://doi.org/10.17159/2309-8988/2019/v39a1","url":null,"abstract":"Surface dust can be a source carrier of viruses, bacteria and air pollution which entail common health issues such as asthma attacks, chest tightness, wheezing and difficulty in breathing. Visually perceived, cleanliness is one measure of indoor air quality and is the subjective assessment of cleaning quality. The aim of this work is to use pattern recognition mediated through a mobile application to analyse and classify dust in households, in order to obtain useful information about the dust sources for the selection of appropriate countermeasures in view to improve air quality and better manage the cleaning of indoor surfaces. The dust type categorization in this work are pollen, rock and ash. This paper also explores the concept of transfer learning techniques and adopts it for small particle classification using CNN models by developing a surface dust application for android smartphones. The behaviour of InceptionV2, InceptionV3, ResNetV2, MobileNetV2 and MobileNetV3 as dust feature extractors were analysed based on their accuracy, precision, recall and Fl-Scoreperformance metrics. Results show that MobileNetV3 model is best suited as a dust feature extractor and rapid dust prediction with an accuracy of up to 92% and low-size storage of only 30 megabytes. Additional Keywords: Android; Classification; Transfer Learning; Smartphone; Surface dust.","PeriodicalId":331389,"journal":{"name":"R&D Journal","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134239951","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Dielectric Elastomer Actuators and Optical Character Recognition in a Braille Display 介电弹性体致动器与盲文显示中的光学字符识别
R&D Journal Pub Date : 1900-01-01 DOI: 10.17159/2309-8988/2022/v38a4
I. Botha, G. Bright, J. Collins
{"title":"Dielectric Elastomer Actuators and Optical Character Recognition in a Braille Display","authors":"I. Botha, G. Bright, J. Collins","doi":"10.17159/2309-8988/2022/v38a4","DOIUrl":"https://doi.org/10.17159/2309-8988/2022/v38a4","url":null,"abstract":"The purpose of this study was the development and experimental validation of a novel portable tactile braille reading device. This design aimed to address the lack of quality braille reading material in South African schools dedicated to the blind and visually impaired. The design was divided into four subsystems: the actuation of the refreshable braille display, the mechanical design of the hand mounted device, the Optical Character Recognition (OCR) software and the electronic control system. The objectives of the study included the design of the electrical, mechanical and software subsystems of the device with emphasis on miniaturisation and a low-cost design, as well as the experimental validation of the haptic feedback and OCR subsystems. The system validation focussed on the experimental analysis of the OCR software design and the Dielectric Elastomer Actuators (DEAs) utilised in the refreshable display. The performance of low-cost elastomer and electrode materials were experimentally assessed during the design of the miniature DEAs. The ideal material combination for the proposed application was identified as a VHB4910 acrylic film lined with MG Chemicals 846 carbon grease. The largest vertical deflections of the diaphragm-type DEA were attained with a stipple-based electrode application, with the elastomer prestrained to 300 % initial area. The OCR program analysis indicated that multiple character recognition was more efficient and less prone to inaccuracies than the initially proposed single character recognition method. The integration of OCR software with miniature DEAs served as a novel approach to text-to-braille transcription.","PeriodicalId":331389,"journal":{"name":"R&D Journal","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115863303","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Characterisation of a Standard Fan Test Facility to Accommodate Reflection of Sound During Noise Measurements 标准风扇测试设备的特性,以适应噪音测量时的声音反射
R&D Journal Pub Date : 1900-01-01 DOI: 10.17159/2309-8988/2022/v38a3
C. D. du Plessis, S. J. van der Spuy, H. Reuter
{"title":"Characterisation of a Standard Fan Test Facility to Accommodate Reflection of Sound During Noise Measurements","authors":"C. D. du Plessis, S. J. van der Spuy, H. Reuter","doi":"10.17159/2309-8988/2022/v38a3","DOIUrl":"https://doi.org/10.17159/2309-8988/2022/v38a3","url":null,"abstract":"Axial flow fans are fundamental to air-cooled condensers. While they provide the air flow for heat transfer, they also generate noise, which is a growing environmental concern. Sound reflections are characterised in an existing fan performance test facility, which does not conform to fan noise measurement standards. Corrections to the measured SPL spectrum is deduced along with the uncertainty in noise measurements. Corrections are compared to a reflection correction standard relating to buildings. This methodology can be repeated for other fan test facilities which do not comply with noise measurement standards.","PeriodicalId":331389,"journal":{"name":"R&D Journal","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124399475","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信