Development of a motor test bench to measure electrical/mechanical parameters 开发电机测试台,用于测量电气/机械参数
2017 International Conference on Energy Conservation and Efficiency (ICECE) Pub Date : 2017-11-01 DOI: 10.1109/ECE.2017.8248830
T. Izhar, M. Ali, M. Sohaib, Abida Nazir
{"title":"Development of a motor test bench to measure electrical/mechanical parameters","authors":"T. Izhar, M. Ali, M. Sohaib, Abida Nazir","doi":"10.1109/ECE.2017.8248830","DOIUrl":"https://doi.org/10.1109/ECE.2017.8248830","url":null,"abstract":"Electrical and mechanical parameters of AC motors are quite significant to be calculated/measured as they share huge portion of industrial load. These parameters may deviate from their manufactured value(name plate parameters) with the passage of time. Therefore the need is to measure these parameters periodically and modify the system accordingly. In this research a novel and eco-nomical motor test bench has been developed to measure performance parameters of (single phase and three phase) new as well as used AC motors more conveniently. Test parameters are displayed on user friendly Human Machine Interface (HMI) screen. Tests are performed according to IEC 60034-2-1.","PeriodicalId":330104,"journal":{"name":"2017 International Conference on Energy Conservation and Efficiency (ICECE)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130210042","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Distributed hybrid control strategy for multiple wind farms under symmetrical and asymmetrical faults 对称和不对称故障下多风电场分布式混合控制策略
2017 International Conference on Energy Conservation and Efficiency (ICECE) Pub Date : 2017-11-01 DOI: 10.1109/ECE.2017.8248824
N. Shaukat, Bilal Khan, S. M. Ali, Usman Munawar, Zahid Ullah
{"title":"Distributed hybrid control strategy for multiple wind farms under symmetrical and asymmetrical faults","authors":"N. Shaukat, Bilal Khan, S. M. Ali, Usman Munawar, Zahid Ullah","doi":"10.1109/ECE.2017.8248824","DOIUrl":"https://doi.org/10.1109/ECE.2017.8248824","url":null,"abstract":"The research study in this paper develop an idea of Hybrid Control Approach (HCA) for electric grid interfaced Multiple Wind Farms (MWFs). The Doubly Fed Induction Generator (DFIG) based MWFs are considered for documented study in this paper. The main attention and focus were drawn towards Rotor Side Converter(RSC) Control. A case study of 27MW grid tied MWFs under symmetrical and asymmetrical faults is carried out in MATLAB/Simulink. In order to validate the effectiveness of the proposed cascaded control strategy, simulation results were compared with PI controller. We effectively reduce rotor side over currents with proposed control approach. The simulation results for electromagnetic torque, further demonstrated enhanced overall performance of the MWFs with proposed control scheme.","PeriodicalId":330104,"journal":{"name":"2017 International Conference on Energy Conservation and Efficiency (ICECE)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125653463","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Assessment of hybrid off-grid wind photovoltaic system: A case study of university campus 离网风光伏混合发电系统评价——以大学校园为例
2017 International Conference on Energy Conservation and Efficiency (ICECE) Pub Date : 2017-11-01 DOI: 10.1109/ECE.2017.8248822
K. S. Khan, Z. Ullah, B. Khan, I. Sami, S. M. Ali, C. A. Mehmood
{"title":"Assessment of hybrid off-grid wind photovoltaic system: A case study of university campus","authors":"K. S. Khan, Z. Ullah, B. Khan, I. Sami, S. M. Ali, C. A. Mehmood","doi":"10.1109/ECE.2017.8248822","DOIUrl":"https://doi.org/10.1109/ECE.2017.8248822","url":null,"abstract":"The new and improved Smart Grid (SG) is replacing conventional electrical grid due to: (a) Integration of renewable energy sources, (b) Demand response programs, (c) energy management system, and (d) supply versus demand management. The electrical demand is typically supplied by conventional fossil fuel generation that induces high cost and increased carbon dioxide (CO2) emissions. Therefore, to overcome abovementioned issues, there is a pressing need to supply the consumer demand using hybrid energy system with low cost and reduced CO2 emissions. The analytical assessment of optimal hybrid power generation system at University campus is performed during load shedding hours or unavailability of power supply from the conventional power system. Further, this paper analyzes four various configurations of the power system that includes: (a) Diesel based, (b) Photo Voltaic (PV) based, (c) Wind based, and (d) Wind and PV based power generation system. Cost of Energy (COE) and Net Present Cost (NPC) plays a vital role in opting for power generation system. Therefore, this research will analyze COE and NPC for the abovementioned configurations using Hybrid Optimization Model for Electric Renewables (HOMER) software. A configuration with reduced COE and NPC will be proposed for University campus.","PeriodicalId":330104,"journal":{"name":"2017 International Conference on Energy Conservation and Efficiency (ICECE)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133046020","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Maisotsenko cycle based counter and cross flow heat and mass exchanger: A computational study 基于Maisotsenko循环的计数器和横流热交换器的计算研究
2017 International Conference on Energy Conservation and Efficiency (ICECE) Pub Date : 2017-11-01 DOI: 10.1109/ECE.2017.8248827
Rasikh Tariq, N. Sheikh
{"title":"Maisotsenko cycle based counter and cross flow heat and mass exchanger: A computational study","authors":"Rasikh Tariq, N. Sheikh","doi":"10.1109/ECE.2017.8248827","DOIUrl":"https://doi.org/10.1109/ECE.2017.8248827","url":null,"abstract":"Maisotsenko Cycle (M-Cycle) is a recently patented and novel thermodynamic cycle which utilizes the renewable latent heat of evaporation of humid air to attain a temperature below the wet-bulb. In contrast, existing evaporative cooling methods can only cool an air to around its wet-bulb temperature. However, the modification in an indirect evaporative cooler has enabled to obtain a temperature below its wet bulb temperature, and towards its dew point temperature. Two types of heat and mass exchangers (HMXes) are under extensive research for air conditioning applications specifically based on M-Cycle applications, namely, counter and cross-flow HMXes. In this research paper, a comparative performance study of both heat exchangers is presented based on their cooling effectiveness, Coefficient of Performance (COP), and cooling capacity. For both types of HMX, balances of mass, momentum and energy are computed. The resulting coupled ordinary differential equations with coupled boundary conditions are discretized using first order accurate finite difference numerical formulation. The governing equations are simulated using purposely developed code. Validation is obtained by comparing the predicted results with experimental studies of HMX in both flow configurations. Results are presented by varying ambient temperature, humidity, and flow rate. It is concluded that a cross flow HMX is more viable for commercial use because of its ease of construction and higher COP values, whereas, a counter flow HMX offers more cooling effectiveness.","PeriodicalId":330104,"journal":{"name":"2017 International Conference on Energy Conservation and Efficiency (ICECE)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125558444","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Investigation of Maisotsenko Cycle (M-cycle) Air-Conditioning System for Multan(Pakistan) 巴基斯坦木尔坦Maisotsenko循环(m循环)空调系统的研究
2017 International Conference on Energy Conservation and Efficiency (ICECE) Pub Date : 2017-06-28 DOI: 10.1109/ECE.2017.8248823
M. Kashif, T. Miyazaki, M. Sultan, Z. Khan, Muhammad H. Mahmood
{"title":"Investigation of Maisotsenko Cycle (M-cycle) Air-Conditioning System for Multan(Pakistan)","authors":"M. Kashif, T. Miyazaki, M. Sultan, Z. Khan, Muhammad H. Mahmood","doi":"10.1109/ECE.2017.8248823","DOIUrl":"https://doi.org/10.1109/ECE.2017.8248823","url":null,"abstract":"This study investigates the applicability of Maisotsenko cycle evaporative cooling system for climatic conditions of Multan region (Pakistan). The study also provides comparison of (Maisotsenko-cycle) M-Cycle based system with other evaporative cooling systems. An experimental system of M-Cycle has been setup and experiments are conducted for various ambient air conditions. The data has been analyzed, and based on the analyses the performance of the proposed M-cycle system has been investigated for summer (April to September) climatic conditions of Multan region (Pakistan). It has been found that the proposed system can provide the useful air-conditioning effect for Multan climate conditions provided that the ambient air relative humidity does not exceed 60%. The system's applicability is found limited in humid conditions, which is due to nature of M-cycle operation.","PeriodicalId":330104,"journal":{"name":"2017 International Conference on Energy Conservation and Efficiency (ICECE)","volume":"148 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121766428","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Review on the role of sustainability techniques in development of green building 可持续发展技术在绿色建筑发展中的作用综述
2017 International Conference on Energy Conservation and Efficiency (ICECE) Pub Date : 2017-06-25 DOI: 10.1109/ECE.2017.8248832
Ubaid ur Rehman, Muhammad Iatisam, W. Younas, Noor ul Hassan Tariq
{"title":"Review on the role of sustainability techniques in development of green building","authors":"Ubaid ur Rehman, Muhammad Iatisam, W. Younas, Noor ul Hassan Tariq","doi":"10.1109/ECE.2017.8248832","DOIUrl":"https://doi.org/10.1109/ECE.2017.8248832","url":null,"abstract":"From the last ten years, Construction of sustainable building becomes significant at international level because of attention of international community towards sustainable development. This paper, based on the adoption of sustainable techniques in the development of Green building, Major barrier towards sustainable construction is the waste generated at the different stages of construction. Waste production causes several problems, such as their deposition make soil infertile and causes environment contamination through, air and water pollution. Material of old buildings can be recycled and use in the construction of new buildings. The construction which consumes less cost, utilize less natural resources with less environmental degradation is known as sustainable construction. Architect and Contractor are the responsible for the sustainable construction. In sustainable construction, Architect designs, building as per client perception but by following sustainability techniques. The contractor is responsible for the implementation of sustainable design. Material selection is the critical step in sustainable construction. Steel is a most appropriate sustainable material produces low waste, efficient and more durable. It has high compressive strength and causes less environmental degradation. Latest technology in sustainable construction is the development of Green Roof which make interior of building pleasant with low cost. The Purpose of this review paper is to present techniques and material selection towards the construction of green building. After the detail analysis on the construction material, suitable adjustment suggested towards the project construction. Sustainable building consumes low cost, causes less environmental degradation and meet today as well as next generation demands.","PeriodicalId":330104,"journal":{"name":"2017 International Conference on Energy Conservation and Efficiency (ICECE)","volume":"52 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121928380","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信