Bartas Abaravicius, Alexandru Moldovan, Sandy Cochran, S. Mitra
{"title":"Development of a Point-of-Care Ultrasound Driver for Applications with Low Power and Reduced Area Requirements","authors":"Bartas Abaravicius, Alexandru Moldovan, Sandy Cochran, S. Mitra","doi":"10.1109/IUS52206.2021.9593342","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593342","url":null,"abstract":"A fully integrated high-voltage pulser driver was developed in TSMC 180 nm BCD for biomedical ultrasound applications. The driver operated at a 20 V regulated supply and was tested with 1.5 MHz and 3.0 MHz therapeutic arrays and a 550 pF capacitive load. The pulser was found to have the longest rise time of 2.1 ns at the maximum capacitive load, and the input-output delay was observed to be 14 ns. The total power consumption of the auxiliary circuit was measured to be $484 mumathrm{W}$ at 100 kHz single pulse repetition rate, whilst the instantaneous current to the load reached 13 A.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115617945","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Takumi Hirata, Deqing Kong, Y. Doshida, M. Kurosawa, M. Aoyagi
{"title":"BNBTM and SCNN lead-free ultrasonic transducer for underwater propulsion system","authors":"Takumi Hirata, Deqing Kong, Y. Doshida, M. Kurosawa, M. Aoyagi","doi":"10.1109/IUS52206.2021.9593626","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593626","url":null,"abstract":"BNBTM and SCNN transducer are investigated as the lead-free acoustic propulsion system. Propulsion measurements are studied to evaluate the performance of BNBTM, SCNN and PZT transducers. The propulsion of the BNBTM and SCNN transducers were 6mN and 0.7mN, when the input power was 3.5W. BNBTM is expected to be a suitable material for endovascular treatment, because of harmless and good performance.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123079261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Anna Gao, Shuicai Wu, D. Tai, Zhuhuang Zhou, P. Tsui
{"title":"Ultrasonic Evaluation of Liver Fibrosis Using the Homodyned K Distribution with an Artificial Neural Network Estimator","authors":"Anna Gao, Shuicai Wu, D. Tai, Zhuhuang Zhou, P. Tsui","doi":"10.1109/IUS52206.2021.9593684","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593684","url":null,"abstract":"Early detection of liver fibrosis is of critical importance. The homodyned K (HK) distribution is a generalized model with the most physical meaning of ultrasonic backscattering. The stage of liver fibrosis can be evaluated by estimating its parameters k and a. However, the estimation of the parameters is complicated. Recently, we have proposed an artificial neural network (ANN) estimator for the HK distribution. In this work, we proposed an improved ANN estimator. Monte Carlo computer simulation was used to generate independent and identically distributed envelope signals of HK distribution, which were used to train an ANN model. Signal-to-noise ratio (SNR) R, skewness S, kurtosis K, X-, and U-statistics were calculated from envelope signals as feature parameters. The inputs of our previous ANN estimator were R2, S2, K2, X and U. In this work, the proposed ANN estimator took parameters R0.72, S0.72, K0.72, R0.88, S0.88, K0.88, X and U as the inputs. Clinical ultrasound radiofrequency (RF) data were divided into Group I (n = 94; liver fibrosis with no hepatic steatosis) and Group II (n = 143; liver fibrosis with mild to severe hepatic steatosis). The RF data were envelope-detected and the eight feature parameters were calculated as the input to the trained ANN model to obtain the estimated k and a values. The receiver operating characteristic (ROC) curve was used for evaluating the diagnostic values of k and a based on the ANN estimator, which were compared with those based on the XU estimator. Computer simulation results show that the proposed ANN estimator outperforms the previous ANN estimator. For Group I, the area under the ROC curve obtained using the k parameter based on the proposed ANN and conventional XU estimators were (0.80, 0.67, 0.60, 0.65) and (0.75, 0.62, 0.59, 0.67) for diagnosing liver ≥F1, ≥F2, ≥F3, ≥F4, respectively. For Group II, compared with the XU estimator, the ANN estimator had comparable diagnostic performance of liver fibrosis. The coexistence of hepatic steatosis affected the detection and diagnosis of liver fibrosis by the HK distribution.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"155 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117056078","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Breaking the Ladder: Synthesis of Acoustic Wave Ladder Filters with Series Resonators Placing Transmission Zeros Below the Passband","authors":"E. Guerrero, J. Verdú, P. de Paco","doi":"10.1109/IUS52206.2021.9593457","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593457","url":null,"abstract":"This work demonstrates how an acoustic wave ladder filter can place transmission zeros below the passband with some of its series resonators. This approach provides an additional degree of flexibility in the structure. Additionally, the same approach is applicable to filters starting in shunt resonator where some shunt resonators can be used to place transmission zeros above the passband. This novel concept, derived from an accurate synthesis approach, enables the design of advanced responses that are not restricted to having the transmission zeros evenly distributed between the upper and the lower stopbands thus achieving improved rejection and selectivity. Synthesized examples of these filters are shown and their Butterworth - Van Dyke model elements are provided.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127230611","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E. Alles, Eleanor C. Mackle, S. Noimark, Adrien E Desiardins
{"title":"Direct Model-Based Inversion for Improved Freehand Optical Ultrasound Imaging","authors":"E. Alles, Eleanor C. Mackle, S. Noimark, Adrien E Desiardins","doi":"10.1109/IUS52206.2021.9593785","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593785","url":null,"abstract":"Optical ultrasound imaging uses light to both generate and detect pulse-echo ultrasound. Recently, we presented a fibre-optic optical ultrasound imaging probe comprising 64 sources and a single receiver that allowed for video-rate, freehand imaging. However, its low number of sources limited the image contrast when using Delay-and-Sum reconstruction. Here, we present an alternative image formation paradigm for optical ultrasound based on model-based inversion, where the low number of sources allows for direct (i.e., non-iterative) inversion under modest hardware requirements. The model accurately incorporates the aperture geometry, frequency-dependent source directivity, and performance variation across the aperture, thereby reducing image artefacts associated with these properties. The method achieves a 15 dB gain in image contrast compared to Delay-and-Sum, at a similar image formation time.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127298148","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ultrafast adaptive coherence beamforming using a fast and simple quad phase estimator","authors":"H. Hewener, S. Tretbar","doi":"10.1109/IUS52206.2021.9593543","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593543","url":null,"abstract":"Ultrafast ultrasound imaging allows total focusing on every pixel, but it uses a non-focusing transmission of the ultrasonic wave into the tissue. Based on plane wave or diverging wave imaging, additional clutter reduces the imaging quality especially in echo-free regions like cysts. Clutter reducing techniques like adaptive beamforming processing compute weighting factors based on measured channel data used for each sample reconstruction. This increases signal and image quality again but adds computational complexity and may result in techniques that are not real-time capable to be implemented in an ultrasound scanner. A fast and accurate phase estimator for real-time applications is needed. Extending the concept of sign coherence factor (SCF) computations using bi-phase estimations, we propose a fast quad phase coherence (QPC) estimator for more accurate phase detection to reduce incoherent clutter. Instead of only using the sign coherence of each of the single channel data, the QPC estimator also includes the monotony of the signal to differentiate into the four classes “positive sign & increasing monotony”, “positive sign & decreasing monotony ”, “negative sign & decreasing monotony” and “negative sign & increasing monotony”. The dominant class of these four is selected and the adaptive weighting is computed as ratio of the absolute frequency of this class to the sum of all other class occurrences. The calculation of the monotony introduces only a small computational overhead compared to other adaptive beamforming techniques. The performance of QPC usage is evaluated using our ultrafast ultrasound research systems at phantom measurements (using “DiPhAS” system with 128 parallel channels) and in-vivo bladder measurements (using “MoUsE” system with 32 parallel channels, 3 MHz phased array transducer). The beamforming reconstruction is computed on the performance-limited integrated PC hardware as OpenCL kernel in real time. Imaging performance is increased compared to sign coherence beamforming (SNR by >3 dB, contrast by 4,4 dB, spatial resolution PSF FWHM by 19%) while computation time still allows real-time usage.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123197137","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Diego Miranda, Rodrigo Olivares, Roberto Muñoz, J. Minonzio
{"title":"A Systematic approach to improve Support Vector Machine applied to ultrasonic guided wave spectrum image classification","authors":"Diego Miranda, Rodrigo Olivares, Roberto Muñoz, J. Minonzio","doi":"10.1109/IUS52206.2021.9593693","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593693","url":null,"abstract":"Osteoporosis is a skeletal disorder characterized by low bone mass, which compromises its resistance and increases the risk of fractures, and is a widespread problem worldwide. Currently, the gold standard for assessing fracture risk is the measurement of the areal bone mineral density with Dual-Energy X-ray Absorptiometry. Several ultrasound techniques have been presented as alternatives. It has been shown that the estimation of cortical thickness and porosity, obtained by Bi-Directional Axial Transmission, are associated with non-traumatic fractures in postmenopausal women. Cortical parameters were derived from the comparison between experimental and theoretical guided modes. However, this model-based inverse approach tends to fail for the patients associated with poor guided mode information. A recent study has shown the potential of an automatic classification tool, Support Vector Machine, to analyze guided wave spectrum images independently of any waveguide model. The aim of this study is to explore how the classification accuracy varies with the number of features. Optimization was done using the Particle Swarm Optimization algorithm, while adjustment was made considering age, body mass index, and cortisone intake. The results show that adjusting the data and optimizing the parameters improved classification. Moreover, the number of features was reduced from 32 to 15, with 73.5% accuracy comparable to the gold standard.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123290595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transtemporal Ultrasound Holograms for Thalamic Therapy","authors":"Diana Andrés, N. Jiménez, F. Camarena","doi":"10.1109/IUS52206.2021.9593685","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593685","url":null,"abstract":"In this work, we numerically investigate the performance of acoustic holograms at 650 kHz to correct the aberrations introduced by the skull and simultaneously target the thalamic nuclei through the temporal bone window. The influence of a misalignment in the skull-lens relative location is also studied in terms of focus pressure and treated volume. For five different holograms we have seen an improvement on the sonicated target volume compared to the sonicated healthy brain tissue, from 1.5 to 9.5 times better than with a focused transducer. For alignment errors in the skull-lens relative position lower than 3.75 degrees of rotation the hologram produces a field with a peak pressure higher that −1 dB the maximum pressure in the correct position. We demonstrate that transtemporal acoustic holograms are a robust method to improve focus quality and to enhance sonicated volumes on target deep-brain even under small misallocations of the therapeutic ultrasound device that can be used for highly selective and low-cost blood-brain barrier opening and neuromodulation applications.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"95 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125283674","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis of the effect of electrode thickness on QCM mass sensitivity","authors":"Wei Pan, Xian-he Huang","doi":"10.1109/IUS52206.2021.9593696","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593696","url":null,"abstract":"In this paper, the effect of the electrode thickness on the mass sensitivity distribution of QCM with a circular electrode is analyzed by the Finite Element Method (COMSOL software). The simulation results show that as the electrode thickness increases, more vibration energy is transferred into the central region of the QCM surface, resulting in the increase of the mass sensitivity in the central region and the decrease of the mass sensitivity in the region outside the center. When the electrode thickness reaches 200 nm, the increase in mass sensitivity will be not obvious. An appropriate thickness range of 100nm-200nm is obtained. The research is meaningful for the design of QCM.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125361392","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Null Subtraction Beamforming for Improved Vessel Resolution in Volumetric Contrast-Enhanced Ultrasound","authors":"Megan Yociss, Katherine G. Brown, K. Hoyt","doi":"10.1109/IUS52206.2021.9593368","DOIUrl":"https://doi.org/10.1109/IUS52206.2021.9593368","url":null,"abstract":"Contrast-enhanced ultrasound (CEUS) is a vascular imaging technique that has several clinical and preclinical applications. It is generally performed in 2-dimensional (2-D) space, which is not ideal for imaging complicated blood vessel networks. Alternatively, volumetric data can be acquired at a high frame rate with 2-D matrix arrays, although the image quality is reduced. Alternatives to conventional delay-and-sum (DAS) beamforming can be used to compensate for the poor resolution and high side lobe levels. The purpose of this research was to determine if the recently developed null subtraction beamforming technique can improve vessel resolution during volumetric CEUS imaging. A tissue-mimicking phantom with a 2.5 mm vessel lumen was perfused with a microbubble contrast agent and imaged with a programmable US scanner (Vantage 256, Verasonics Inc) equipped with a 1024-element matrix array transducer (7.5 MHz, Vermon). Volumetric data was acquired and beamformed with both null subtraction and conventional DAS. The resulting temporal maximum intensity projections were compared. Qualitatively, the vessel lumen was clearer and side lobe noise was greatly reduced by null subtraction beamforming. The signal-to-noise ratio (SNR) of the vessel was also improved from 9.8 dB for DAS to 13.3 dB for null subtraction. Null subtraction beamforming is a simple technique that improves the quality of volumetric CEUS images acquired using a 2-D matrix array transducer.","PeriodicalId":329239,"journal":{"name":"2021 IEEE International Ultrasonics Symposium (IUS)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125385674","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}