Innovative sol-gel coatings for corrosion protection of connector housings 创新的溶胶-凝胶涂层,用于连接器外壳的防腐
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969778
J. Acquadro, S. Noël, P. Chrétien, F. Houze, P. Teste, C. Genet, H. Azougaghe, F. Ansart, M. Gressier, M. Menu, R. Montpellaz, O. Gavard, R. Leroy, G. Tredan, S. Demarthon, T. Pichot, F. Raoul, M. Ladiré
{"title":"Innovative sol-gel coatings for corrosion protection of connector housings","authors":"J. Acquadro, S. Noël, P. Chrétien, F. Houze, P. Teste, C. Genet, H. Azougaghe, F. Ansart, M. Gressier, M. Menu, R. Montpellaz, O. Gavard, R. Leroy, G. Tredan, S. Demarthon, T. Pichot, F. Raoul, M. Ladiré","doi":"10.1109/HLM54538.2022.9969778","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969778","url":null,"abstract":"This paper presents the electrical properties of innovative sol-gel coatings for connectors. A first study has shown the feasibility of developing a conducting and anti-corrosion coating for connector housing based on sol-gel chemistry. Such coatings aimed at replacing cadmium and chromium (VI) as recommended by REACH and RoHS regulations must have equivalent properties. A large consortium has been established in order to tackle aspects of the project from the formulation, the characterizations and the scale-up phases. The electrical properties of the coatings are obtained with conductive fillers of various types. We present here electrical characterizations both at the macroscopic scale and at the microscopic scale and try to correlate the conduction to the various parameters involved in the complex mechanisms ruling the film formation.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"494 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126887319","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Commissioning of a novel high power medium voltage DC laboratory with exemplary studies on an MVDC hybrid contactor 一个新型大功率中压直流实验室的试运行,对MVDC混合接触器进行示范性研究
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969834
Frederik Anspach, P. Vieth, D. Bösche, T. Kopp, Ernst-Dieter Wilkening, M. Kurrat
{"title":"Commissioning of a novel high power medium voltage DC laboratory with exemplary studies on an MVDC hybrid contactor","authors":"Frederik Anspach, P. Vieth, D. Bösche, T. Kopp, Ernst-Dieter Wilkening, M. Kurrat","doi":"10.1109/HLM54538.2022.9969834","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969834","url":null,"abstract":"DC Grids become more relevant in diverse application areas. In addition, the increasing operating voltage leads to a lack of suitable laboratories to investigate future components. Therefore, a new test facility is built and presented in this paper. Two air insulated three phase transformers with several terminal connectors allow a flexible voltage adjustment. A connected 12 pulse thyristor-controlled rectifier provides a voltage up to 12 kV or a current up to 30 kA. The maximum output power is limited 18 MW due to mains supply restrictions. A sophisticated control and safety system allow tests to be conducted for almost any type of load investigation on a wide range of breaking equipment. The complete circuit configuration is explained and some initial tests on a new medium voltage hybrid circuit breaker are presented. This switch is designed to operate at a supply voltage of 3 kV, so fast switching is critical. The results are investigated and necessary design improvements are derived. The laboratory and the newly constructed switch are the basis for new research fields in hybrid and DC switches in general.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127954872","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Analysis of Failure Mechanisms of Electrical Connectors in Long-term Use Field Vehicles 长期使用野战车辆电连接器失效机理分析
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969820
Dirk Hilmert, Haomiao Yuan, Jian Song
{"title":"The Analysis of Failure Mechanisms of Electrical Connectors in Long-term Use Field Vehicles","authors":"Dirk Hilmert, Haomiao Yuan, Jian Song","doi":"10.1109/HLM54538.2022.9969820","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969820","url":null,"abstract":"The function and reliability of electrical connectors in automotive applications is crucial for vehicle safety, especially with regard to E-mobility and autonomous driving. For this reason, electrical connectors are being developed for long-term use applications. However, a small amount of function failures are still being observed in long-term use field vehicles. In this study all electrical connectors of five long-term driven vehicles from various car manufacturers are disassembled and analyzed. The same analysis procedure is followed for every vehicle and the electrical resistance of the connectors is measured to determine electrical failures. The contacts of failed connectors are further analyzed using optical microscopy, XRF spectroscopy, EDS and detailed contact resistance mapping. By comparing the connectors with electrical failures to the same types of connectors with a proper electrical resistance, failure mechanisms can be detected and analyzed. The frequency of various failure mechanisms is statistically evaluated. The results of the analysis provide valuable indications with respect to improvement of the reliability of connectors.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"161 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123506660","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Comprehensive Study on the Contact Materials and Geometry of an MVDC Piezoelectrically Actuated Switch MVDC压电驱动开关触点材料和几何结构的综合研究
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969829
Alfonso Cruz-Feliciano, Zhiyang Jin, T. Damle, M. Tousi, Nickolas Lee, L. Graber
{"title":"Comprehensive Study on the Contact Materials and Geometry of an MVDC Piezoelectrically Actuated Switch","authors":"Alfonso Cruz-Feliciano, Zhiyang Jin, T. Damle, M. Tousi, Nickolas Lee, L. Graber","doi":"10.1109/HLM54538.2022.9969829","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969829","url":null,"abstract":"An optimization of the moving contact plate of a piezoelectrically actuated fast mechanical switch is presented. The Ashby method is used to identify suitable materials for this application to minimize contact mass and power loss. Finite element analysis is employed to optimize the moving contact plate geometry and ensure uniform current density. In addition, the best performing geometries are thermally studied to understand thermal rectification.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130253529","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Influence of Time-Frequency Transforms on AC and DC Arc Fault Signal Representation 时频变换对交直流电弧故障信号表示的影响
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969817
Silei Chen, Yuanfeng Wang, Yu Meng, Xingwen Li, Shiwei Ge
{"title":"The Influence of Time-Frequency Transforms on AC and DC Arc Fault Signal Representation","authors":"Silei Chen, Yuanfeng Wang, Yu Meng, Xingwen Li, Shiwei Ge","doi":"10.1109/HLM54538.2022.9969817","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969817","url":null,"abstract":"Series arc faults and system transitions display different electrical signal profiles in multiple kinds of systems. To guarantee effective arc fault detection, the representation influence of time-frequency transform methods is urgent to be understood for the definition of the most promising features to be used for the arc fault detection in ac and dc systems. At first, an experimental setup of arc faults is designed in ac and dc systems defined in UL1699B and IEC62606 standards in this paper. Then series arc fault electrical signals are obtained at different sampling frequency bands. Arc fault noise would show insignificant variations with external noise from operating loads, resulting in detection difficulties for wavelet based methods. Next, time-frequency transform methods including singular value decomposition (SVD) and variation mode decomposition (VMD) are applied to analyze the time-frequency representation of arc fault signals, which would improve the wavelet feature by 8.6% and 30.43% respectively. Finally, the calculation order and Teager energy operator (TEO) are further applied to improve ac and dc arc fault features. This research is aimed to provide portable arc fault features for wider arc fault conditions based on the common arc fault characteristics.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132910594","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Generation of asymmetric topographic structures in Cu-Sn connectors using extended direct laser interference patterning for the tailoring of insertion and removal forces 在Cu-Sn连接器中使用扩展的直接激光干涉图图化来定制插入和移除力的不对称地形结构
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969800
Silas Schütz, S. Suárez, D. Britz, F. Mücklich
{"title":"Generation of asymmetric topographic structures in Cu-Sn connectors using extended direct laser interference patterning for the tailoring of insertion and removal forces","authors":"Silas Schütz, S. Suárez, D. Britz, F. Mücklich","doi":"10.1109/HLM54538.2022.9969800","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969800","url":null,"abstract":"The reduction of insertion forces of separable electrical connections has been one of the main demands of the connector industry, and most solutions combine the use of lubricants with a specific connector design. An important challenge here is that there is a need for a solution that requires lower contact forces during mating while still ensuring a stable electrically conductive connection, without compromising the mechanical stability of the connection in operation. Extended direct laser interference patterning (xDLIP) was used here to generate asymmetric saw-tooth structures on Sn-coated Cu connectors. The main objective is generating an anisotropic tribological behavior, in which the insertion force is significantly lower than the removal force. Topographical interlocking is the main mechanism governing the observed anisotropy. The tailored connectors were characterized tribologically and electrically by simulating insertion/removal cycles and determining the evolution of the contact resistance at the end of each insertion motion. Different structural inclinations, counter-electrode geometry, and contact forces were evaluated. For certain combinations, it is possible to observe substantial differences between the insertion and removal forces, of up to 4 times. Summarizing, this work presents a chemistry-free route to influence the insertion and removal forces in connectors, without affecting the electrical characteristics at their contact spot.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121339746","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Effects of Mechanical Design on Passive Intermodulation in Coaxial Connectors 机械设计对同轴连接器无源互调的影响
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969770
Junyu Luo, G. Flowers, Jinchun Gao, Lingyu Bi
{"title":"Effects of Mechanical Design on Passive Intermodulation in Coaxial Connectors","authors":"Junyu Luo, G. Flowers, Jinchun Gao, Lingyu Bi","doi":"10.1109/HLM54538.2022.9969770","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969770","url":null,"abstract":"Passive intermodulation (PIM) is a thorny issue that exists in a wide array of coaxial connectors at high frequency. One important factor in the occurrence of PIM interference are the details of the mechanical design of a given coaxial connector. Accordingly, characterizing the impact of such effects on PIM provides both improved technical understanding and analysis tools for the optimization of a connector's mechanical design for the minimization of PIM. In the present work, the effects of the mechanical design on passive intermodulation in coaxial connectors were investigated using both modeling and experimental testing. The effects of both the geometrical length and angle of coaxial connectors were analyzed. Based on transmission line theory, an equivalent circuit model of varying geometrical length was developed. Considering the signal reflection at the angle, the coaxial connector was treated as equivalent to an unmatched transmission line, and an equivalent circuit model of varying geometrical angles was also developed. SubMiniature version A (SMA) connectors fabricated with different lengths and angles were selected as experimental samples and PIM tests were conducted to validate the models and analysis results. The experimental measurements show good agreements with the simulation results. Analysis of the results provide insight into the conditions for which mechanical design considerations may be a significant driver of PIM in connector systems. The techniques developed and demonstrated in this study provide tools and procedures that may assist in evaluating and improving PIM performance in proposed connector designs.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"81 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123358952","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Modeling and Analysis of Electrical-Thermal Performance of the Contact Surface of Coaxial Connectors at High Frequency and High Power 高频大功率同轴连接器接触面电热性能建模与分析
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969768
Yuqi Zhou, Jinchun Gao, G. Flowers
{"title":"Modeling and Analysis of Electrical-Thermal Performance of the Contact Surface of Coaxial Connectors at High Frequency and High Power","authors":"Yuqi Zhou, Jinchun Gao, G. Flowers","doi":"10.1109/HLM54538.2022.9969768","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969768","url":null,"abstract":"In high frequency and high-power signal transmission, the quality of the signal is negatively impacted by high temperatures of the contact surfaces in coaxial connectors. The voltage-temperature (V-T) relation is often used to calculate the maximum temperature of electrical contacts, but the measured temperature may not match the theoretical value for high frequency and high-power signal transmission. In this study, a model of the temperature distribution of the contact surface of a coaxial connector was developed. Finite element analysis (FEA) simulations were performed to evaluate the influence of the power and frequency on the temperature of the contact surface, and the electrical and thermal performances of sample coaxial connectors were analyzed. Experiments were conducted to measure the contact temperature for various power and frequency levels. By comparing the measured contact temperature of the test samples with the values calculated using the V-T equation, it was found that the equation may not yield accurate predictions for connectors operating at high frequency and high power. These results show significantly improved predictive capability in high frequency and high power.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124727539","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Steady-State Thermal Analysis of Electric Fuse using Finite Element Method 基于有限元法的保险丝稳态热分析
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969810
Ying Sun, Todd Dietsch
{"title":"Steady-State Thermal Analysis of Electric Fuse using Finite Element Method","authors":"Ying Sun, Todd Dietsch","doi":"10.1109/HLM54538.2022.9969810","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969810","url":null,"abstract":"Electric fuses are widely used for electrical safety purposes for many years in different levels of electrical systems. In this paper, the steady-state thermal analysis of an automotive fuse using the finite element method is presented. A fuse thermal model was developed as a simulation benchmark. Thermal characterization tests were carried out to validate the thermal model with an average error between simulation and measurements of ∼4.4%. The thermal model provides a useful tool for fuse design and development.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121431374","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Simulation and Measurement of the Magnetic Field Signature of a Vacuum Circuit Breaker and the Identification of Arcing 真空断路器磁场特征的仿真与测量及电弧的识别
2022 IEEE 67th Holm Conference on Electrical Contacts (HLM) Pub Date : 2022-10-23 DOI: 10.1109/HLM54538.2022.9969821
Ning Guo, K. Whitmore, Morris Cohen, Tohid Shekari, R. Beyah, L. Graber
{"title":"Simulation and Measurement of the Magnetic Field Signature of a Vacuum Circuit Breaker and the Identification of Arcing","authors":"Ning Guo, K. Whitmore, Morris Cohen, Tohid Shekari, R. Beyah, L. Graber","doi":"10.1109/HLM54538.2022.9969821","DOIUrl":"https://doi.org/10.1109/HLM54538.2022.9969821","url":null,"abstract":"Magnetic field emission of circuit breakers during load switching contains valuable information. Our previous work has shown the application of the magnetic field signature during load-switching events to measure the arc duration and to detect potential malicious intrusion of the substation. To apply the approach to a wide variety of circuit breakers, a simulation model is required due to the complexity of circuit breaker experiments. This paper establishes a model to simulate the circuit breaker magnetic signature generated during load-switching events and a suitable approach to process the signal from the measurement system. Four models have been built to simulate the influence of each step on the B-field waveform. The physical connection between the magnetic signatures and the circuit breaker load switching is explained based on the results. The model is verified by comparing simulated results with the magnetic field measurements from a real vacuum circuit breaker when it cuts off an alternating current of up to 2.5 kA (peak). The difference between the simulated and measured magnetic field and the possible reasons that cause the discrepancy are discussed. The model serves as a start point for accurately simulating the magnetic signatures. Several optimizing approaches are proposed for future study to improve the simulation model and enable the simulation of circuit breakers with different structures and arc-extinguishing technologies.","PeriodicalId":327697,"journal":{"name":"2022 IEEE 67th Holm Conference on Electrical Contacts (HLM)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130224722","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书