2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)最新文献

筛选
英文 中文
Selection and Structural Design of Reactive Power Compensators for a 200 MW Floating Offshore Wind Farm 200mw海上浮式风电场无功补偿器的选择与结构设计
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8997074
Ga-Eun Jung, M. Dinh, H. Sung, Jae-In Lee, Minwon Park
{"title":"Selection and Structural Design of Reactive Power Compensators for a 200 MW Floating Offshore Wind Farm","authors":"Ga-Eun Jung, M. Dinh, H. Sung, Jae-In Lee, Minwon Park","doi":"10.1109/ICRERA47325.2019.8997074","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8997074","url":null,"abstract":"In this paper, the reactive power compensator of a 200 MW offshore wind farm was discussed. The proper capacity and control method of the reactive power compensator were chosen to compensate for the reactive power generated by the power transmission cable and to meet the grid code. In order to select the type of reactive power compensator, an economic analysis was carried out taking into account the capital expenditure and operating expenses of the reactive power compensator, and the transient analysis was performed using PSCAD/EMTDC. The combination of a fixed shunt reactor and a static VAR compensator was chosen in consideration of the grid code, economy, dynamic control characteristics and fault-ride-through capability. These results can be used to effectively select reactive power compensation devices for offshore wind farms.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116764002","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Experimental Investigation of Efficiency Map for an Inverter-Fed Surface-Mount Permanent Magnet Synchronous Motor 变频馈电表面贴装永磁同步电机效率图的实验研究
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996549
Milad Golzar, H. Van Khang, Martin Marie Hubert Choux, Alf Magne Midtb⊘ Versland
{"title":"Experimental Investigation of Efficiency Map for an Inverter-Fed Surface-Mount Permanent Magnet Synchronous Motor","authors":"Milad Golzar, H. Van Khang, Martin Marie Hubert Choux, Alf Magne Midtb⊘ Versland","doi":"10.1109/ICRERA47325.2019.8996549","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996549","url":null,"abstract":"Losses in inverter-fed permanent magnet motors are underestimated by using analytical or numerical approach since additional losses due to extra harmonics of the frequency converter are normally skipped. Further, losses in switches and passive components of the converter and the effect of switching frequencies cannot be numerically taken into consideration. Loss-minimizing control and proper efficiency analysis of inverter-fed permanent magnet motors cannot be achieved if an efficiency map is built based on a numerical investigation of the motors alone. This works first reviews losses in a surface-mount permanent magnet synchronous motor (SPMSM) and frequency converters. The efficiency map of a surface-mount permanent magnet synchronous motor in both motoring and generating mode, voltage source inverter and entire drive considering the effect of the switching frequency and modulation, is experimentally investigated in different load conditions. Finally, an appropriate range of switching frequencies in order to maximize the drive efficiency is recommended through the investigation.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121112800","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design and Implementation of Sensorless DC Voltage Regulation for Shunt Active Power Filter Based Single Phase P-Q Theory 基于单相P-Q理论的并联有源电力滤波器直流无传感器稳压设计与实现
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996561
I. Colak, O. Kaplan
{"title":"Design and Implementation of Sensorless DC Voltage Regulation for Shunt Active Power Filter Based Single Phase P-Q Theory","authors":"I. Colak, O. Kaplan","doi":"10.1109/ICRERA47325.2019.8996561","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996561","url":null,"abstract":"In this study, the sensorless DC voltage regulation approach for a shunt active power filter (SAPF) has been suggested. The proposed approach has been combined with the single-phase p-q theory to enhance power quality of the grid. The sensorless DC voltage regulation is based on the calculation of the operating losses of the SAPF throughout each operation period. The validity of the proposed approach is evaluated by simulation study realized in Matlab/Simulink, and confirmed on the power system prepared in the laboratory. The results of the arranged simulation and the implementation studies demonstrate that the sensorless DC voltage regulation is as effective as the proportional-integral used classically in the SAPF applications. Due to reduced number of sensors, the developed combination is not complicated, and its cost is less than classical PI control.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127326672","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Protection of Stand-Alone Wind Energy Conversion System using Bridge Type Fault Current Limiters 桥式故障限流器对单机风能转换系统的保护
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996727
M. Bhaskar, S. Premalatha, Arjun Parameswaran, P. Dinesh, S. Dash
{"title":"Protection of Stand-Alone Wind Energy Conversion System using Bridge Type Fault Current Limiters","authors":"M. Bhaskar, S. Premalatha, Arjun Parameswaran, P. Dinesh, S. Dash","doi":"10.1109/ICRERA47325.2019.8996727","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996727","url":null,"abstract":"There is a need to protect large wind farms from fault conditions. The paper has a wind turbine generator system producing power for single phase loads located at different lengths of the transmission lines. In this paper, initially, over current relay was used to protect the system. Over current relay employs inverse time- current characteristics to perform the tripping operation. Because of relay operation, the current flow is intermittent in the lines. Further studies were done on to limit the fault current magnitude flowing in the circuit. For this purpose, Fault Current Limiter was used. Fault Current Limiter consists of bridge arrangement of diodes and thyristors for normal operation. Anti- parallel arrangement of diodes with thyristors with a reactance limits the fault current magnitude. It was found that by using Fault Current Limiter, the fault current magnitude was reduced by a greater degree.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"476 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127440761","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
SHA-512 based Wireless Authentication Scheme for Smart Battery Management Systems 基于SHA-512的智能电池管理系统无线认证方案
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996531
Ahmad Al Khas, I. Çiçek
{"title":"SHA-512 based Wireless Authentication Scheme for Smart Battery Management Systems","authors":"Ahmad Al Khas, I. Çiçek","doi":"10.1109/ICRERA47325.2019.8996531","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996531","url":null,"abstract":"Modern cyber-physical systems depend on the battery backup systems for continuous service. Due to excessive wiring requirements, the traditional methods used for battery authentication cannot be applied to modern smart batteries, especially when they are composed of large number of cells. In this work, we proposed a wireless battery authentication scheme for use with the battery management system and the cells to prevent potential hardware attacks through the trojan cells. We designed a SHA-512 IP Core which operates at 90MHz, and occupies 976 CLB slices and one block RAM on a Xilinx Artix-7 FPGA device. We integrated the SHA-516 module with a synthesizable CPU to be able to create a real-world test scenario and finally we verified the correct operation of an example authentication protocol through a wireless communication channel established with the use of two ESP8266 based WiFi modules.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123339188","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Analysis of Grid Connected Wind Power System 并网风电系统分析
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996528
E. Bekiroglu, Muhammed Duran Yazar
{"title":"Analysis of Grid Connected Wind Power System","authors":"E. Bekiroglu, Muhammed Duran Yazar","doi":"10.1109/ICRERA47325.2019.8996528","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996528","url":null,"abstract":"The importance of renewable energy sources has increased rapidly in recent years. Among these renewable energy sources, wind energy comes to leading due to its advantages such as clean, sustainable and cost-effective. Wind power energy source is an intermittent energy source. The power output can vary widely because of the random variables of wind speed. The wind turbine output is equal to wind speed's cube. The grid-connected wind power which includes many paralleled wind turbines, transformers and collection lines, will affect stability of the power system. In the present study, the grid-connected wind power system has been analyzed for 30 km, 120 km transmission lines where wind speeds are 6 m/s, 11 m/s, respectively. Simulation results and conclusions have been given for impact of wind speed and transmission line length on active power, reactive power, and power factor.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125585820","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Novel application of Selfish Herd Optimisation based Two Degrees of Freedom Cascaded Controller for AGC Study 基于自利群体优化的二自由度级联控制器在AGC研究中的新应用
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996512
N. Jena, Nimai Charan Patel, S. Sahoo, B. K. Sahu, S. Dash, K. Mohanty, R. Bayindir
{"title":"Novel application of Selfish Herd Optimisation based Two Degrees of Freedom Cascaded Controller for AGC Study","authors":"N. Jena, Nimai Charan Patel, S. Sahoo, B. K. Sahu, S. Dash, K. Mohanty, R. Bayindir","doi":"10.1109/ICRERA47325.2019.8996512","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996512","url":null,"abstract":"The aim of this paper is to investigate the automatic generation control (AGC) issues of a two-area power system comprising of five diversified sources like thermal unit, hydro unit, wind unit, diesel unit and a photovoltaic (PV) unit. Distinctive non-linearities, for example, governor dead band (GDB), generation rate constraint (GRC), and Boiler dynamics of the concerned sources are contemplated. A novel two degree of freedom PID with derivative filter cascaded with PD with derivative filter (2DOF-PIDN-PDN) controller is designed by applying a bio-inspired optimization algorithm named Selfish Herd Optimization (SHO) to ameliorate the dynamic performance over PID controller. The improved dynamic response as well as robustness analysis confer that the recommended 2DOF-PIDN-PDN controller is more superior and proficient.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114938794","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Analysis on Hotspot Technologies and Cutting-edge Technologies of Organic Solar Cells Based on Patent Data 基于专利数据的有机太阳能电池热点技术与前沿技术分析
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996522
Qimei Chen, Fang Chen
{"title":"Analysis on Hotspot Technologies and Cutting-edge Technologies of Organic Solar Cells Based on Patent Data","authors":"Qimei Chen, Fang Chen","doi":"10.1109/ICRERA47325.2019.8996522","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996522","url":null,"abstract":"The objective of this paper is to identify and forecast the technological development of organic solar cells by the analysis of patents. This paper researches the unsupervised machine learning methods and complex network theory. Based on the Python language, the K-means++ algorithm is used to cluster the data for discovering hotspot technologies, the theory of structure holes is used to identify potential cutting-edge technologies. The results indicate the hotspot technologies of organic solar cells are mainly involved in the five fields: device architecture and morphology control, electrode and electron transport layer design, active layer design, interface materials and fabrication, battery assembly and packaging process. And the potential cutting-edge technologies include: fabrication and morphology of active layer, device structure and interface engineering, transparent electrodes and substrates, donor and acceptor materials, and so on. The proposed analysis framework in this paper is applicable to different science and technology domains.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115531815","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A Skewness Based Method for Diagnosis in Quasi-Z T-Type Grid-Connected Converters 一种基于偏度的准z型t型并网变流器诊断方法
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996558
T. Amaral, V. Pires, A. Cordeiro, D. Foito
{"title":"A Skewness Based Method for Diagnosis in Quasi-Z T-Type Grid-Connected Converters","authors":"T. Amaral, V. Pires, A. Cordeiro, D. Foito","doi":"10.1109/ICRERA47325.2019.8996558","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996558","url":null,"abstract":"One of the very interesting converters for transformerless grid-connected PV systems is the multilevel quasi-Z T-Type inverter. Besides their multilevel operation, it presents voltage Boost capability and robustness to instantaneous switching between power semiconductors of the same leg and capability to work in fault tolerant condition. However, to ensure this capability, it is essential to ensure a fast and correct diagnosis of the component under fault. Thus, this paper proposes a new method for the detection of an open switch fault. The proposed approach uses the inverter AC line currents that will be analyzed by a Skewness based method. The method has the capability to distinguish the switch under fault. Besides that, it presents robustness to interferences such as noise, as well is insensible to variations of the injected power into the grid. Several simulation and experimental results will be presented in order to verify the capability of the proposed method. 963478217","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"280 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122292378","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Energy Modeling Output of Wind System based on Wind Speed 基于风速的风系统能量建模输出
2019 8th International Conference on Renewable Energy Research and Applications (ICRERA) Pub Date : 2019-11-01 DOI: 10.1109/ICRERA47325.2019.8996525
A. Harrouz, I. Colak, K. Kayisli
{"title":"Energy Modeling Output of Wind System based on Wind Speed","authors":"A. Harrouz, I. Colak, K. Kayisli","doi":"10.1109/ICRERA47325.2019.8996525","DOIUrl":"https://doi.org/10.1109/ICRERA47325.2019.8996525","url":null,"abstract":"There are many renewable energy sources that can be used to obtain electrical energy from natural sources in the world. Especially, wind energy plays an increasing role thanks to its feasibility and efficiency. Due to the source of wind energy, efficiency of wind farm is highly depending on the weather conditions. The main issue to obtain maximum performance is to predict the output. This situation provides collaborative production of different energy sources more efficiently with avoiding over-cost and overproduction. In this paper, there are three different wind models are modelled and simulated with choosing the complete and correct models.","PeriodicalId":319933,"journal":{"name":"2019 8th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128426501","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 28
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书