1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)最新文献
{"title":"Evaluation of high performance converters under low dose rate total ionizing dose (TID) testing for NASA programs","authors":"A.K. Sharma, K. Sahu, S. Kniffin","doi":"10.1109/REDW.1998.731494","DOIUrl":"https://doi.org/10.1109/REDW.1998.731494","url":null,"abstract":"This paper reports the results of low dose rate (0.02-0.04 Rads(Si)/sec) TID tests performed on several types of high performance analog-to-digital and digital-to-analog converters (ADCs/DACs). The test results showed that BiCMOS parts were very susceptible to radiation damage at very low levels [2-5 kRads(Si)] and the bipolar parts showed higher tolerance [20-100 kRads(Si)] depending on the part type and manufacturer.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126627145","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dose rate and total dose dependence of the 1/f noise performance of an operational amplifier fabricated on a complimentary bipolar process on bonded wafer","authors":"D. Hiemstra","doi":"10.1109/REDW.1998.731488","DOIUrl":"https://doi.org/10.1109/REDW.1998.731488","url":null,"abstract":"Dose rate and total dose dependence of the 1/f noise performance of an operational amplifier fabricated on a complimentary bipolar process on bonded wafer are presented. Possible noise performance degradation mechanisms are described.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128243010","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Radiation testing for space applications at the National Physical Laboratory","authors":"A. Williams, M. McEwen, Alan Dusautoy","doi":"10.1109/REDW.1998.731495","DOIUrl":"https://doi.org/10.1109/REDW.1998.731495","url":null,"abstract":"The electron linear accelerator at the National Physical Laboratory can be used to simulate the space environment for radiation testing of electronic components. This paper describes the accelerator facility and gives examples of the work carried out in this field in recent years.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133701785","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Total dose and single event effects testing of UTMC commercial RadHard/sup TM/ gate arrays","authors":"D. Kerwin, J. Benedetto","doi":"10.1109/REDW.1998.731481","DOIUrl":"https://doi.org/10.1109/REDW.1998.731481","url":null,"abstract":"Results from total dose and single event effects testing of a UTMC Microelectronic Systems Commercial RadHard/sup TM/ gate array standard evaluation circuit (SEC) are reported. Total dose levels up to 300 krad(Si) and error rates of less than 1/spl times/10/sup -10/ errors/bit-day, with no single event latch-up (SEL), were demonstrated. Results from total dose testing of capacitor test structures from AMI's 0.6 /spl mu/m mixed signal process are also reported, indicating the possibility of greater than 200 krad(Si) total dose hardness for 0.6 /spl mu/m CMOS when processed with the UTMC Commercial RadHard/sup TM/ process module.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134357735","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Crain, W. Crain, K. Crawford, S. Hansel, P. Yu, R. Koga
{"title":"Single event effects test results for the 80C186 and 80C286 microprocessors and the SMJ320C30 and SMJ320C40 digital signal processors","authors":"S. Crain, W. Crain, K. Crawford, S. Hansel, P. Yu, R. Koga","doi":"10.1109/REDW.1998.731471","DOIUrl":"https://doi.org/10.1109/REDW.1998.731471","url":null,"abstract":"Two generations of the 80Cx86 microprocessor family and two floating-point digital signal processor (DSP) of the SMJ320Cx0 family were tested for single event effects (SEE). The test results are presented here.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"102 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115628467","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. Lacoe, J. V. Osborn, D. C. Mayer, S. Brown, D.R. Hunt
{"title":"Total-dose radiation tolerance of a commercial 0.35 /spl mu/m CMOS process","authors":"R. Lacoe, J. V. Osborn, D. C. Mayer, S. Brown, D.R. Hunt","doi":"10.1109/REDW.1998.731487","DOIUrl":"https://doi.org/10.1109/REDW.1998.731487","url":null,"abstract":"We have measured the properties of test structures from two different lots fabricated at Hewlett-Packard on their 0.35 /spl mu/m CMOS process after exposure to total ionizing radiation. The threshold voltage shifts associated with the gate oxide were shown to be small, consistent with the presence of a thin gate oxide. Measurements on various ring oscillators indicated no change in gate delay or power with exposure to radiation, consistent with minimal shifts in transistor threshold voltages. A discrepancy was observed between the two lots for NMOS minimal geometry transistors. Transistors from the earlier lot showed no additional off-state leakage, even at a total ionizing dose (TID) of 300 krad, while transistors from the more recent lot showed up to 1 /spl mu/A leakage at 300 krad. Measurements of field-oxide transistors from the first lot indicated the p-substrate did not invert at doses up to 300 krad. Unfortunately, the field oxide transistors from the second lot were not functional. The observed discrepancies between the two lots will require further measurements on future lots.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"358 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122810955","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Artamonov, A. Chumakov, V. Eremin, I. Figurov, O. Kalashnikov, O. Nikiforov, O. Sogojan
{"title":"\"REIS-IE\" X-ray tester: description, qualification technique and results, dosimetry procedure","authors":"A. Artamonov, A. Chumakov, V. Eremin, I. Figurov, O. Kalashnikov, O. Nikiforov, O. Sogojan","doi":"10.1109/REDW.1998.731498","DOIUrl":"https://doi.org/10.1109/REDW.1998.731498","url":null,"abstract":"The original \"REIS-IE\" X-ray tester for IC total-dose radiation effects investigation is developed. The qualification technique is described and tests results are presented. The dosimetry procedure is validated in \"REIS-IE\" vs. Cobalt-60 comparative tests.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127593563","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High total dose response of the UTMC gate array fabricated at Lockheed Martin Federal Systems","authors":"J. Benedetto, A. Bishop, M. Martin, N. Haddad","doi":"10.1109/REDW.1998.731483","DOIUrl":"https://doi.org/10.1109/REDW.1998.731483","url":null,"abstract":"The radiation response of the UTMC Microelectronic Systems (UTMC) FA01 gate array standard evaluation circuit (SEC) was measured up to a total ionizing dose of 10 Mrad(Si) using a Co-60 source. Each SEC consists of 9 functional blocks, all of which remained fully functional throughout the accumulation of total dose. In addition to functional testing, the SEC was monitored for parameter shifts in quiescent current (Q/sub IDD/), propagation delays, input buffer data transition voltage, and output buffer drive voltage. All parameters were within specified values during the tests.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"112 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114953981","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Single event effects on commercial SRAMs and power MOSFETs: final results of the CRUX flight experiment on APEX","authors":"J. Barth, J. Adolphsen, G. Gee","doi":"10.1109/REDW.1998.731465","DOIUrl":"https://doi.org/10.1109/REDW.1998.731465","url":null,"abstract":"The CRUX experiment on the APEX satellite monitored single event effects on 1 Mbit and 256 Kbit SRAMs and 100 volt and 200 volt power MOSFETs. The single event upsets (SEUs) on the SRAMs were mapped in geographic and geomagnetic coordinates. Other single event effects (SEEs) were observed, including multiple bits upsets (MBUs) and single hard errors (\"stuck bits\"). Sensitivity to programmed logic state was also analyzed. The relatively large sample sizes for most part types and almost two year flight time in a hostile radiation environment provided a data set adequate for investigation of the range in device response within the flight lots. Single event burn-out (SEB) conditions were observed on the power MOSFETs. The rates on the 200 volt devices were much higher than on the 100 volt and occurred primarily in regions of space dominated by trapped protons.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127751664","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Total ionizing dose effects on voltage-to-frequency converters","authors":"C. Lee, A. Johnston, B. Rax","doi":"10.1109/REDW.1998.731489","DOIUrl":"https://doi.org/10.1109/REDW.1998.731489","url":null,"abstract":"Three different voltage-to-frequency converters were tested to determine how ionizing radiation affected their critical specifications. All three were fabricated with bipolar technologies. A popular charge-balancing architecture converter, AD652, was most sensitive with low dose rate (LDR) due to its tight specifications. The other astable-multivibrator architecture converters, AD537 and AD654, performed much better at high dose rate and low dose rate.","PeriodicalId":317656,"journal":{"name":"1998 IEEE Radiation Effects Data Workshop. NSREC 98. Workshop Record. Held in conjunction with IEEE Nuclear and Space Radiation Effects Conference (Cat. No.98TH8385)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125354821","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}