{"title":"Quality monitoring and assurance for laser beam cutting using a thermographic process control","authors":"H. Haferkamp, M. Goede, A. von Busse","doi":"10.1117/12.364276","DOIUrl":"https://doi.org/10.1117/12.364276","url":null,"abstract":"This paper presents an optical method of process control based on the thermographic detection of signals from the process zone. At the Laser Zentrum Hannover e.V., a monitoring system based on a high-temperature camera has been developed to enable on-line monitoring of the cut quality. During the cutting process, the temperature field was observed on-line using a thermocamera. The camera images were analyzed afterwards using specific digital image analysis. The crucial task of the work is the adequate application of analyzing and visualization techniques to extract significant information from the measured signals, and to find correlations to the cutting quality. Investigations have been carried out on cutting metal sheet materials such as steels and titanium. For the investigations, different process parameters such as laser power or process gas pressure were varied. Influences of the optical set-up on the signal were studied. Results show that the temperature distribution in the process zone is strongly connected to the cut quality, e.g. dross attachment, surface roughness of the cut kerf, width of the kerf. Observation of the temperature and temperature gradients at the cutting front allow a determination of the resulting cut quality.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"47 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115710751","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"WinGS: optical measurement and inspection system for aircraft wind tunnel models","authors":"A. Zilker, D. Winter","doi":"10.1117/12.364270","DOIUrl":"https://doi.org/10.1117/12.364270","url":null,"abstract":"In the development of new airplane generations at DaimlerChrysler Aerospace extensive testing of new designs and geometries is performed in the wind tunnel. Models to various scales are built from steel and aluminum by milling. To achieve optimum performance in the airstream, the model surface is hand-finished according to the CAD design geometry. In the past this finishing process was controlled in several measurement loops with a tactile coordinate measurement machine. This was very time consuming and could only be performed at discrete points of the model surface. The optical measurement and inspection system WinGS (Wing Geometry Sensor) was developed to significantly increase the speed of the shape control process and to measure the complete 3D-surface of the model. The system consists of a fringe projection sensor with photogrammetric orientation. The 3D-geometry of the model surface is digitized and the deviation from the designed CAD model is calculated and displayed as a 2D false color map. The complete measurement, analysis and display cycle time is 25 seconds. The accuracy of the system is plus or minus 0.03 mm on whitened surfaces up to 400 X 280 mm2. The overall measurement volume is 1.5 X 1 X 0.5 m3.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"134 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114441293","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Active vision approach for optimizing illumination in critical surface inspection by machine vision","authors":"T. Pfeifer, L. Wiegers","doi":"10.1117/12.364248","DOIUrl":"https://doi.org/10.1117/12.364248","url":null,"abstract":"This paper describes a new method for the adaptive control of imaging parameters in automized machine vision systems. By these new methods even in case of critical objects, which show metal and specular reflections or having polished surfaces, the imaging parameters like illumination can be adjusted optimally without any prior knowledge about the surface characteristics. As a result, an image is generated, which is almost free of irrelevant information in the image. This optimized image only contains the 'real' edges actually found on the object's surface and is free of effects resulting from specular reflections or shadows. Surface inspection for scratches, texture analysis or for dimensional measurements becomes much more reliable now.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116830792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Three-dimensional micromeasurements on smooth and rough surfaces with a new confocal optical profiler","authors":"R. Artigas, Agustí Pintó, F. Laguarta","doi":"10.1117/12.364243","DOIUrl":"https://doi.org/10.1117/12.364243","url":null,"abstract":"One of the objectives of surface metrology is to obtain a better and faster assessment of the micro- or nanogeometry of component surfaces. In this way the innovative concept of the profiler is changing towards non-contact modular computer- controlled systems for measuring and analyzing shape and texture of a surface. In this paper we present a new instrument which is based on the concept of confocal microscopy. In this instrument (which may be used for measurements on smooth and rough surfaces) a pattern of slits is imaged by a very high numerical aperture optical system on the surface of the sample to be measured. The reflected or diffused light is observed with a CCD array and analyzed with different digital image processing algorithms. In addition to the replacement of the existing stylus systems there are also important new potential applications for this type of instrument. We present the results obtained in micro- or nanomeasurements of high precision optical surfaces, texture assessment of non-homogeneous liquid depositions and metrology of microstructures such as master gratings and certified calibration standards. The obtained results show that the confocal profiler is robust enough to provide a surface topography with spatial resolution lower than 0.5 micrometer and uncertainty of about 10 nm.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128522547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zhiguo Wang, T. Walz, H. R. Schubach, A. Ettemeyer
{"title":"Three-dimensional pulsed ESPI technique of analysis of dynamic problems","authors":"Zhiguo Wang, T. Walz, H. R. Schubach, A. Ettemeyer","doi":"10.1117/12.364249","DOIUrl":"https://doi.org/10.1117/12.364249","url":null,"abstract":"Pulsed ESPI techniques have been developed during the last years to replace conventional double pulse holography interferometer for analysis of dynamic behavior of components. The main benefits of holography towards conventional measuring techniques have already been known as field and non-contact measurement results. Recent developments have extended the capabilities of pulsed ESPI techniques to 3D measurement of dynamic behavior. The object under investigation is illuminated with the light of a pulsed laser and simultaneously observed from 3 different directions with 3 ESPI cameras. The measuring results from the 3 cameras are representing the deformation field in the 3 sensitivity directions of the optical set-up. The optical image distortion due to the different viewing angles of the 3 cameras is automatically compensated and the complete 3D-deformation vector is calculated on every point of the inspected surface. Recent industrial applications of the 3D pulsed ESPI technique have been identified and carried out in the field of automotive NVH applications, aerospace and railway technique.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126592178","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Object pose monitoring for multifinger grippers by laser scanning","authors":"T. Fischer, H. Woern","doi":"10.1117/12.364247","DOIUrl":"https://doi.org/10.1117/12.364247","url":null,"abstract":"The human hand is a very complex grasping tool to handle objects of different size and shape. A lot of research work has been done to transfer these capabilities to artificial robot hands, called multifinger grippers. The major part of this work describes the controlling of multifinger grippers. Since there is no information about the object's pose available in real-time, the finger joint positions or the fingertip positions of the gripper are position feedback controlled. But the global goal is to handle an object. Therefore, it is more useful to control the object's pose itself. In this paper object pose monitoring by laser scanning is presented. With the help of laser scanning the object's pose is controlled in real-time. Some results of the object pose monitoring show this ability.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132134597","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Toward robust and distant estimation of the wear on a track vehicle's wheels","authors":"D. Holm, G. Stanke","doi":"10.1117/12.364260","DOIUrl":"https://doi.org/10.1117/12.364260","url":null,"abstract":"A serious problem for the operation of track vehicles, especially trams, is the uneven wear of the wheels caused by a discontinuous driving regime. To maintain the safety and comfort the diameter of the wheels should be closely matched. For this reason the diameter of the wheels must be periodically measured. The measurement has to be carried out automatically when the vehicle is moving slowly across the measurement system. The measurement system is based on triangulation, therefore a laser line is projected onto the wheel's rolling surface orthogonal to the axle, such that an arc of about 400 mm length is marked. The arc is registered using a medium resolution, high speed CMOS image sensor featuring high dynamic range. A two step circle approximation using the minimum squared error criterion is performed. In the first step the circle is approximated including all points of the arc. In the second step points having a larger distance from the estimated circle are discarded, then the approximation is repeated. Initial simulations and tests with a standard CCD image sensor showed a potential measurement accuracy of about 0.1 mm with common wheel diameters.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128299771","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
W. Steinchen, Peter Maeckel, J. Nickel, Frank Voessing, G. Kupfer
{"title":"Digital refinement of interferograms obtained by double-pulse interferometry and automatic sign correction of phase gradients after FFT evaluation","authors":"W. Steinchen, Peter Maeckel, J. Nickel, Frank Voessing, G. Kupfer","doi":"10.1117/12.364246","DOIUrl":"https://doi.org/10.1117/12.364246","url":null,"abstract":"Applying the pulse laser to speckle methods, nonuniformities of the laser beam profiles and the intensities between each laser pulse have unpleasant consequences on the intensity distribution of the recorded images and following on the expected fringes of the corresponding subtractive result. This contribution introduces a computer based technique for compensating this technical and physical problem, so that the fringe quality is improved, even if the homogeneity of the laser beam profiles is on such low level, that the conventional (subtractive) technique fails. The solution is based on algorithms, which refines each intensity distribution and is comparable with the known shading correction. After this refinement the interferogram can be processed by the well known Fourier transform evaluation of the relative phase distribution. Applying the FFT, practical problems arise when it comes to the step of automatic sign corrections. The contribution will discuss an approach of automatic sign correction. The methods for refinement and automatic sign correction following the Fourier transform evaluation is explained in detail and demonstrated on selected interferograms.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134389974","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Laser diffraction wire diameter measurements: correction of diffraction models by interferometric calibration","authors":"J. C. Martínez-Antón, I. Serroukh, E. Bernabeu","doi":"10.1117/12.364275","DOIUrl":"https://doi.org/10.1117/12.364275","url":null,"abstract":"The laser diffraction is a robust and precise technique to monitor wire diameters in-line. However, classical Fraunhofer diffraction formulas are not appropriate for 3-dimensional object size determination. The Babinet's principle allow to use such formulas only for angles of diffraction that tend to zero. A real diffraction measurement necessarily takes a finite angular range (approximately 10 degrees) and therefore, an error will be introduced if using classical formulas. The exact electromagnetic formulation is not appropriate to deal with 3-D objects, basically because it does not provide explicit formulas to determine the wire diameter. We have worked a pseudo-empirical approach out to reach simple accurate and reliable diffraction formulas that use exclusively the fringe pattern. To validate the diffraction formulas we need a calibration of the wire diameter. To accomplish this, we have introduced a hybrid set-up which allows interferometric and diffraction measurements over the same area of the wire. Using a He-Ne laser and a plus or minus 10 degree measurement range we observe, typically, a diameter overestimation of approximately 0.5 microns for different metallic wires (approximately 30 - 300 micrometer). From this work, we can also extract a practical physical insight to diffraction phenomena in terms of the Geometrical Theory of Diffraction (GTD). Many optical techniques for metrology of high resolution must take into account diffracted light.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125362769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Pieńkowski, J. Rzepka, Slawomir Sambor, Henryk Pawolka
{"title":"Laser system for wavelength of laser interferometer calibration","authors":"J. Pieńkowski, J. Rzepka, Slawomir Sambor, Henryk Pawolka","doi":"10.1117/12.364256","DOIUrl":"https://doi.org/10.1117/12.364256","url":null,"abstract":"The laser interferometers are intended for high-precision measurement of distances and displacements. The calibration equipment for the definition of real meaning of the laser radiation wavelength and investigation of wavelength stability and reproducibility of the laser radiation in the laser interferometers is presented in paper. The laser radiation frequency was measured with the heterodyne method using the developed laser frequency iodine standard 633 nm. The system was used for calibration the frequency of the He-Ne Zeeman laser used in the two frequency laser interferometer.","PeriodicalId":312967,"journal":{"name":"Industrial Lasers and Inspection","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133939599","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}