Anais do Congresso Brasileiro de Automática 2020最新文献

筛选
英文 中文
Effects of Wave Propagation Velocity on Fault Location Approaches in Power Distribution Systems 波传播速度对配电系统故障定位方法的影响
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1239
Leonardo R. Fernandes, Victor P. Dardengo, Thiago R. Fernandes
{"title":"Effects of Wave Propagation Velocity on Fault Location Approaches in Power Distribution Systems","authors":"Leonardo R. Fernandes, Victor P. Dardengo, Thiago R. Fernandes","doi":"10.48011/asba.v2i1.1239","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1239","url":null,"abstract":"To reduce the frequency and duration of interruptions on the energy supply, electric utilities should adopt efficientfault location approaches. Traveling wave-based methods are a good alternative for fault location, as they are more accurate, faster, and less affected by the fault characteristics than the traditional impedance-based approaches. Basically, the accuracy of traveling wave-based approaches depends on the precise identification of the wavefronts arrival times in the meters, as well as on their traveling wave velocities. However, most of the traveling wave-based approaches adopt a single traveling wave velocity to estimate fault locations, which may affect the accuracyof the estimates since the waves tend to travel at different velocities in conductors with different physical characteristics. This paper investigates the effects of wave propagation velocities on fault location estimates via traveling wave-based approaches. Mathematical morphology is used to identify the arrival time of the traveling waves generated by faults on the meters. Different velocities, calculated based on the electrical parameters of thenetwork conductors, are used to determine the fault location in a real distribution system.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125406683","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Inferência dos Estágios Iniciais da COVID-19 em Portugal 对葡萄牙COVID-19早期阶段的推断
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.978
F. C. Batista, Americo Cunha
{"title":"Inferência dos Estágios Iniciais da COVID-19 em Portugal","authors":"F. C. Batista, Americo Cunha","doi":"10.48011/asba.v2i1.978","DOIUrl":"https://doi.org/10.48011/asba.v2i1.978","url":null,"abstract":"Atualmente, o novo coronavírus SARS-CoV-2 é uma ameaça à saúde da população mundial. A aparente rápida disseminação do vírus criou uma pandemia, e países em todo o mundo estão a lutar com um aumento de casos infetados. Neste sentido, o presente artigo insere-se nesse esforço de tentar compreender melhor a dinâmica inicial da COVID-19 em Portugal, em particular, com vistas para estimar uma provável data de início do surto epidêmico. Utilizando a informação veiculada pelas autoridades de saúde e usando o modelo logístico clássico, é apresentada uma modelagem dos estágios iniciais da doença no país, com a noção da sua respetiva incerteza. Esse modelo permite inferir um intervalo para a ocorrência do primeiro caso de COVID-19 em Portugal que é anterior à notificação oficial.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127796900","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Seleção de modelos epidemiológicos via análise de sensibilidade global 通过全球敏感性分析选择流行病学模型
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.982
Michel Tosin, Americo Cunha, F. C. Coelho
{"title":"Seleção de modelos epidemiológicos via análise de sensibilidade global","authors":"Michel Tosin, Americo Cunha, F. C. Coelho","doi":"10.48011/asba.v2i1.982","DOIUrl":"https://doi.org/10.48011/asba.v2i1.982","url":null,"abstract":"Este paper propõe uma metodologia de seleção de modelos epidemiológicos via critério da informação de Akaike trazendo como novidade a construção de uma função de verossimilhança baseada nos resultados de uma análise de sensibilidade global através dos índices de Sobol obtidos usando expansão em polinômios caos. A ideia geral é incorporar a informação sobre a influência dos parâmetros na resposta para selecionar um modelo mais interessante dentro do conjunto de candidatos. A estratégia é aplicada a um conjunto de modelos compartimentais compatíveis aos usados para analisar a pandemia de COVID-19 recente, permitindo compará-los sem a presença de dados experimentais.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132777892","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Comparative Study of Technologies for Harmonic Propagation Mitigation in Subsea Power Systems 海底电力系统谐波传播减缓技术的比较研究
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1032
Gustavo C. B. Leal, J. Costa, D. Oliveira, Matheus Sotero da Silva Ribeiro, E. L. Emmerik, M. Aredes
{"title":"Comparative Study of Technologies for Harmonic Propagation Mitigation in Subsea Power Systems","authors":"Gustavo C. B. Leal, J. Costa, D. Oliveira, Matheus Sotero da Silva Ribeiro, E. L. Emmerik, M. Aredes","doi":"10.48011/asba.v2i1.1032","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1032","url":null,"abstract":"This article discusses the exhaustive study of resonances in Subsea Power Systems (SPS) through the interaction of harmonics, caused by diode rectiers, and a comparative study of possible solutions to the problem. For this purpose, a large volume of simulations was carried out in the PSCAD/EMTDC simulation environment, in its parallel processing environment, to check for indications of the existence of problems in an subsea distribution system.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133040903","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Localização de Faltas em Redes VSC-HVDC por RNA e Coeficientes de Frequência Mel Cepstrais 利用ann和Mel Cepstrais频率系数对VSC-HVDC网络进行故障定位
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1174
G. A. L. Neto, Rui Bertho, H. M. G. C. Branco
{"title":"Localização de Faltas em Redes VSC-HVDC por RNA e Coeficientes de Frequência Mel Cepstrais","authors":"G. A. L. Neto, Rui Bertho, H. M. G. C. Branco","doi":"10.48011/asba.v2i1.1174","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1174","url":null,"abstract":"Com o crescimento dos sistemas de transmissão de corrente contínua, é necessário propor e analisar métodos eficientes para localização de faltas. Esta pesquisa tem como objetivo obter e avaliar o desempenho de um algoritmo de localização de faltas em uma linha de transmissão de 200 km. O sistema VSC-HVDC de dois terminais foi modelado no Simulink e os dados foram pré-processados com os Coeficientes de Frequência Mel Cepstrais, do inglês Mel-Frequency Cepstral Coefficients (MFCC). Em seguida, uma Rede Neural Artificial (RNA) foi usada para estimar a localização da falta. Vários cenários foram simulados, variando a resistência e a localização da falta ao longo da linha. O baixo erro verificado na estimativa da distância demonstra a alta confiabilidade do método na localização da falta.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131836748","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Novel Gaussian State Estimator based on H2 Norm and Steady-State Variance 基于H2范数和稳态方差的新型高斯状态估计器
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1259
A. A. D. Paula, Víctor C. S. Campos, G. Raffo, B. Teixeira
{"title":"Novel Gaussian State Estimator based on H2 Norm and Steady-State Variance","authors":"A. A. D. Paula, Víctor C. S. Campos, G. Raffo, B. Teixeira","doi":"10.48011/asba.v2i1.1259","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1259","url":null,"abstract":"This paper proposes a novel state estimator for discrete-time linear systems with Gaussian noise. The proposed algorithm is a fixed-gain filter, whose observer structure is more general than Kalman one for linear time-invariant systems. Therefore, the steady-state variance of the estimation error is minimized. For white noise stochastic processes, this performance criterion is reduced to the square H2 norm of a given linear time-invariant system. Then, the proposed algorithm is called observer H2 filter (OH2F). This is the standard Wiener-Hopf or Kalman-Bucy filtering problem. As the Kalman predictor and Kalman filter are well-known solutions for such a problem, they are revisited.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131977762","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Aplicação da Linguagem Python na Localização de Faltas em Linhas de Transmissão Através do Kit Smart Grid 通过智能电网套件应用Python语言定位输电线路故障
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1106
I. M. Cordeiro, A. R. Almeida, B. F. S. Júnior, N. X. Melo
{"title":"Aplicação da Linguagem Python na Localização de Faltas em Linhas de Transmissão Através do Kit Smart Grid","authors":"I. M. Cordeiro, A. R. Almeida, B. F. S. Júnior, N. X. Melo","doi":"10.48011/asba.v2i1.1106","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1106","url":null,"abstract":"Esse trabalho apresenta um algoritmo de localização de faltas usando a Teoria das Ondas Viajantes - TOV e Transformada Wavelet Discreta – TWD, através do Python. A linguagem Python é apresentada como uma linguagem de programação para extração de características de dados de sinais de faltas modeladas em linhas de transmissão usando o Kit Smart Grid. Os resultados encontrados neste artigo apresentaram uma boa acurácia na localização da falta com erros abaixo de 1% para faltas fase-terra.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114038969","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Modelamento Fenomenológico de um Músculo de Mckibben de Baixo Custo 低成本麦基本肌肉的现象学建模
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1013
M. H. S. Bomfim, E. J. Lima
{"title":"Modelamento Fenomenológico de um Músculo de Mckibben de Baixo Custo","authors":"M. H. S. Bomfim, E. J. Lima","doi":"10.48011/asba.v2i1.1013","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1013","url":null,"abstract":"Com o aumento da interação física entre humanos e robôs, seja no ambiente fabril ou equipamen-tos de engenharia assistiva, pesquisas científicas passaram a desenvolver novos atuadores, além dos moto-res elétricos. A finalidade é tornar o contato entre o ser humano e a máquina mais seguro. Nesse cenário, um forte candidato a atuador é o músculo de Mckibben. O músculo de Mckibben é um tipo de músculo artificial pneumático que possui dinâmica rápida, similar aos motores elétricos, elevada razão potência/peso e baixo custo de aquisição de peças. Além disso, o atuador tem complacência natural similar ao tecido muscular esquelético, o que pode suavizar colisões catastróficas ou emular o comportamento da muscula-tura humana. Assim, esse artigo propõe o desenvolvimento e a caracterização de um músculo de Mckibben, para aplicações no campo da robótica de manipulação. Como metodologia, foram utilizadas soluções ana-líticas baseadas em teorias de deformação para materiais poliméricos e soluções numéricas baseadas em regressões e interpolações lineares, permitindo a caracterização estática e dinâmica do atuador. Como re-sultado, o estudo obteve um atuador de baixo custo, em torno de R$5,00, e elevados coeficientes de corre-lação, R entre 0,8424 e 0,9969, para o modelamento fenomenológico.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121275084","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reference Model-based Fault Detection and Isolation for Discrete-time Systems Subject to Persistent Disturbances 基于参考模型的持续扰动离散系统故障检测与隔离
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1043
Silvane Schons, D. Coutinho, M. Kinnaert
{"title":"Reference Model-based Fault Detection and Isolation for Discrete-time Systems Subject to Persistent Disturbances","authors":"Silvane Schons, D. Coutinho, M. Kinnaert","doi":"10.48011/asba.v2i1.1043","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1043","url":null,"abstract":"This paper deals with the design of a robust lter aimed for fault detection and isolation applied to discrete-time systems subject to arbitrary (not necessarily vanishing) normbounded (i.e., `1) input disturbances. The idea is to approximate the behavior from faults to residual given by a reference model despite the presence of disturbances. The lter design iscast as an optimization problem subject to linear matrix inequality constraints. A numerical example is presented to demonstrate the potential of the proposed approach.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121416914","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Metodologia para Análise do Desempenho Dinâmico de Pequenas Centrais Hidrelétricas em Operação Isolada 小型水电站孤立运行动态性能分析方法
Anais do Congresso Brasileiro de Automática 2020 Pub Date : 2020-12-08 DOI: 10.48011/asba.v2i1.1070
Douglas de Castro Karnikowski, Luis Felipe Bianchi Carbonera, A. G. D. Costa, F. A. Farret, Daniel P. Bernardon
{"title":"Metodologia para Análise do Desempenho Dinâmico de Pequenas Centrais Hidrelétricas em Operação Isolada","authors":"Douglas de Castro Karnikowski, Luis Felipe Bianchi Carbonera, A. G. D. Costa, F. A. Farret, Daniel P. Bernardon","doi":"10.48011/asba.v2i1.1070","DOIUrl":"https://doi.org/10.48011/asba.v2i1.1070","url":null,"abstract":"O ilhamento de uma fonte de energia ocorre quando uma parte da rede elétrica é suprida exclusivamente por uma unidade ou grupo de geradores isolados da rede elétrica principal. Para manter os níveis de tensão e frequência em valores adequados na operação isolada de uma Pequena Central Hidrelétrica (PCH), o comportamento da rede elétrica dependerá da resposta dos controladores, da dinâmica da turbina hidráulica e do gerador. Entretanto, com a pequena inércia do gerador isolado e a dinâmica lenta da turbina hidráulica, a rede isolada fica mais susceptível a violações dos níveis de qualidade local da energia elétrica em relação a rede principal. Desta forma, este artigo propõe uma metodologia para análise do desempenho dinâmico de uma PCH operando no modo isolado através da avaliação do comportamento de uma PCH em operação isolada durante a desconexão da rede elétrica principal e no restabelecimento do fornecimento de energia elétrica.","PeriodicalId":309853,"journal":{"name":"Anais do Congresso Brasileiro de Automática 2020","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128956256","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书