Journal of Energy最新文献

筛选
英文 中文
An Accurate Iron Core Loss Model in Equivalent Circuit of Induction Machines 感应电机等效电路中铁芯损耗的精确模型
Journal of Energy Pub Date : 2020-02-15 DOI: 10.1155/2020/7613737
B. Nasir
{"title":"An Accurate Iron Core Loss Model in Equivalent Circuit of Induction Machines","authors":"B. Nasir","doi":"10.1155/2020/7613737","DOIUrl":"https://doi.org/10.1155/2020/7613737","url":null,"abstract":"Iron core loss is the major loss in electrical machines. It performs up to 25% of total machine losses. The machine efficiency calculation requires an accurate prediction of losses. The accuracy of losses calculation depends largely on the equivalent circuit parameter determination and measurements. In this paper, an accurate procedure of iron core loss determination considering the variation effect of supply voltage, iron core temperature, rotor parameters due to skin effect, and magnetizing saturation. The iron core resistance is performed as main component in the equivalent circuit. This resistance is a function of supply voltage and used to calculate part of stray loss as well as iron core loss. The theoretical model is compared with practical results with high accuracy, which proves the validity of the proposed procedure.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"4 1","pages":"1-10"},"PeriodicalIF":0.0,"publicationDate":"2020-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74446624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
Development of High Performance Airfoils for Application in Small Wind Turbine Power Generation 小型风力发电用高性能翼型的研制
Journal of Energy Pub Date : 2020-02-07 DOI: 10.1155/2020/9710189
Emmanuel Yeboah Osei, Richard Opoku, A. Sunnu, M. Adaramola
{"title":"Development of High Performance Airfoils for Application in Small Wind Turbine Power Generation","authors":"Emmanuel Yeboah Osei, Richard Opoku, A. Sunnu, M. Adaramola","doi":"10.1155/2020/9710189","DOIUrl":"https://doi.org/10.1155/2020/9710189","url":null,"abstract":"Small wind turbine power generation systems have the potential to meet the electricity demand of the residential sector in developing countries. However, due to their exposure to low Reynolds number (Re) flow conditions and associated problems, specific airfoils are required for the design of their blades. In this research, XFOIL was used to develop and test three high performance airfoils (EYO7-8, EYO8-8, and EYO9-8) for small wind turbine application. The airfoils were subsequently used in conjunction with Blade Element Momentum Theory to develop and test 3-bladed 6 m diameter wind turbine rotors. The aerodynamic performance parameters of the airfoils tested were lift, drag, lift-to-drag ratio, and stall angle. At , EYO7-8, EYO8-8, and EYO9-8 had maximum lift-to-drag ratios of 134, 131, and 127, respectively, and maximum lift coefficients of 1.77, 1.81, and 1.81, respectively. The stall angles were 12° for EYO7-8, 14° for EYO8-8, and 15° for EYO9-8. Together, the new airfoils compared favourably with other existing low Re airfoils and are suitable for the design of small wind turbine blades. Analysis of the results showed that the performance improvement of the EYO-Series airfoils is as a result of the design optimization that employed an optimal thickness-to-camber ratio ( ) in the range of 0.85–1.50. Preliminary wind turbine rotor analysis also showed that the EYO7-8, EYO8-8, and EYO9-8 rotors had maximum power coefficients of 0.371, 0.366, and 0.358, respectively.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"2020 1","pages":"1-9"},"PeriodicalIF":0.0,"publicationDate":"2020-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81634428","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Potential of Abattoir Waste for Bioenergy as Sustainable Management, Eastern Ethiopia, 2019 《屠宰场废物作为可持续管理的生物能源潜力》,埃塞俄比亚东部,2019
Journal of Energy Pub Date : 2020-02-01 DOI: 10.1155/2020/6761328
S. Tolera, Fekade Ketema Alemu
{"title":"Potential of Abattoir Waste for Bioenergy as Sustainable Management, Eastern Ethiopia, 2019","authors":"S. Tolera, Fekade Ketema Alemu","doi":"10.1155/2020/6761328","DOIUrl":"https://doi.org/10.1155/2020/6761328","url":null,"abstract":"Our environment is facing serious problems of high volumes of waste generation and inadequate disposal system in worldwide particularly in developing countries. There is also lack of studies on quantification of abattoir waste and lack of workers awareness towards abattoir waste. Therefore, the purpose of the study was to estimate abattoir waste for bioenergy potential as sustainable management. A cross-sectional study was conducted in four selected abattoirs of Eastern Ethiopia from January 1st, 2018 to December 30th, 2018. The magnitude of abattoir waste composition was computed based on Aniebo mathematical computational from the actual number of slaughtered livestock. The study demonstrated that four selected abattoirs generate 1,606.403 ton of abattoir waste per year and using anaerobic digestion of about 85,139 m3/year of biogas and 111.25 ton/year of biofertilizer can be produced. The biogas or energy from the waste can replace firewood and charcoal and the expensive fossil fuels. Using Banks mathematical computation about 20,054.12 m3/year production of biogas could replace 20.56 ton/year of energy consumed by liquefied petroleum gas, kerosene, charcoal, furnace oil, petrol, and diesel in average. The current estimated biofertilizer (111.25 ton/year) from four abattoir sites can cover about 2,225 hectares/year with its advantage and efficiency of soil. When turned into cost, about $55,645 per year of price could estimate from biogas and biofertilizer. The study concluded that huge amount of biogas and dry biofertilizer yields could produce from abattoir waste through anaerobic digestion. Therefore, installing anaerobic digestion plant is recommended to ensure environmental safety and public health.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"32 1","pages":"1-9"},"PeriodicalIF":0.0,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74413834","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Comparative Study of the Grid Side Converter’s Control during a Voltage Dip 电压跌落时电网侧变换器控制的比较研究
Journal of Energy Pub Date : 2020-02-01 DOI: 10.1155/2020/7892680
Hind Elaimani, A. Essadki, Noureddine Elmouhi, R. Chakib
{"title":"Comparative Study of the Grid Side Converter’s Control during a Voltage Dip","authors":"Hind Elaimani, A. Essadki, Noureddine Elmouhi, R. Chakib","doi":"10.1155/2020/7892680","DOIUrl":"https://doi.org/10.1155/2020/7892680","url":null,"abstract":"The modeling and control of a wind energy conversion system based on the Doubly Fed Induction Generator DFIG is the discussed theme in this paper. The purpose of this system was to control active and reactive power converted; this control is ensured thanks to the control of the two converters. The proposed control strategies are controlled by PI regulators and the sliding mode technique. In the present work a comparison of the robustness of the 2 controls of the grid side converter (GSC) during a voltage dip is shown. The simulation is carried out using the Matlab/Simulink software with a 300 kW generator.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"1 1","pages":"1-11"},"PeriodicalIF":0.0,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88157536","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Removal of Hydrogen Sulfide from Biogas Using a Red Rock 用红石去除沼气中的硫化氢
Journal of Energy Pub Date : 2020-01-27 DOI: 10.1155/2020/2309378
Mrosso, Revocatus Lazaro Machunda, T. Pogrebnaya
{"title":"Removal of Hydrogen Sulfide from Biogas Using a Red Rock","authors":"Mrosso, Revocatus Lazaro Machunda, T. Pogrebnaya","doi":"10.1155/2020/2309378","DOIUrl":"https://doi.org/10.1155/2020/2309378","url":null,"abstract":"The potential of red rock (RR) materials for the removal of H2S from biogas was studied. The rock samples were collected, sieved, and organized in various particle size ranges such as 0.32-250 μm, 250-500 μm, 500-750 μm, 750 μm-1 mm, and 1-1.5 mm. These samples were calcinated at the various temperatures as 500°C, 750°C, and 1000°C and then characterized for phase composition by energy-dispersive X-ray florescent technique, surface morphology by Zeiss Ultra Plus Field Emission Scanning Electron Microscopy (FE-SEM), and surface area by the Brunauer-Emmett-Teller (BET) method. The calcinated RR was filled in the bed reactor, and biogas was allowed to pass through the adsorbent while recording the inlet and exit concentration of H2S. The results show that particle size, calcination temperature, adsorbent mass, and biogas flow rate were parameters that influenced the removal efficiency and adsorption capacity of RR. The sample sieved at 0.32-250 μm and calcinated at a temperature of 1000°C showed 95% high removal efficiency and adsorption capacity of 0.37 g/100 g of the sorbent. Regeneration of spent materials when exposed to air, keep on by reuse in the column, appeared to have nearly similar removal efficiency as the original calcined sample. Thus, the overall performance of the material is promising, which is due to the presence of metals such as iron and magnesium, among others. Therefore, proving the successful elimination of contaminant, RR is an available material for biogas purification.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"24 1","pages":"1-10"},"PeriodicalIF":0.0,"publicationDate":"2020-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75721050","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Semi-Transparent Building Integrated Photovoltaic Solar Glazing: Investigations of Electrical and Optical Performances for Window Applications in Tropical Region 半透明建筑集成光伏太阳能玻璃:热带地区窗户应用的电学和光学性能研究
Journal of Energy Pub Date : 2019-12-17 DOI: 10.1155/2019/6096481
Benedicto Joseph, Baraka Kichonge, T. Pogrebnaya
{"title":"Semi-Transparent Building Integrated Photovoltaic Solar Glazing: Investigations of Electrical and Optical Performances for Window Applications in Tropical Region","authors":"Benedicto Joseph, Baraka Kichonge, T. Pogrebnaya","doi":"10.1155/2019/6096481","DOIUrl":"https://doi.org/10.1155/2019/6096481","url":null,"abstract":"Integrating solar PV technology with semi-transparent windows permits multifunctional operation as electricity generation and allowing natural light to enter the building, hence overall energy efficiency improvement. The performance of the semi-transparent building integrated PV glazing on office building facade has been investigated in Tanzania’s tropical climate. Experimental measurements of the electrical and optical parameters for the system efficacy evaluation were done at various conditions which included cloudy, normal, and clear sky days. The weather parameters under consideration were solar irradiance, air temperature, relative humidity, and wind speed. The experimental set-up consisted of building integrated silicon mono crystalline semi-transparent PV module rated at 50 W and accessories. The I-V and P-V curves were measured at different irradiances. Throughout the experiment, the observed module temperature was between 20°C and 51°C and the air temperature was 17–33°C while the humidity was recorded at the range of 23–63%. Module electrical efficiency was observed to vary from 4% to 9% while the visible light transmission was obtained between 11% and 19%. It was proved that at high temperature regardless of irradiance increase, there were observed output power and efficiency drops caused by high heat losses.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"1 1","pages":"1-10"},"PeriodicalIF":0.0,"publicationDate":"2019-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90884931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Determination of the Surface Roughness Parameter and Wind Shear Exponent of Kisii Region from the On-Site Measurement of Wind Profiles 基于风廓线现场测量的基溪地区地表粗糙度参数和风切变指数测定
Journal of Energy Pub Date : 2019-07-01 DOI: 10.1155/2019/8264061
Laban N. Ongaki, C. Maghanga, Kerongo Joash
{"title":"Determination of the Surface Roughness Parameter and Wind Shear Exponent of Kisii Region from the On-Site Measurement of Wind Profiles","authors":"Laban N. Ongaki, C. Maghanga, Kerongo Joash","doi":"10.1155/2019/8264061","DOIUrl":"https://doi.org/10.1155/2019/8264061","url":null,"abstract":"The research sought to investigate the surface roughness parameter (Zo) and wind shear exponent (α) of Kisii region (elevation 1710m above sea level, 0.68°S, 34.79°E). A six-month experiment was set at three sites of Kisii region. Two PRO AcuRite 01036 Wireless Weather Stations with pro+ 5-in-1 Sensors were placed at different hub heights above the ground and data were sent and received by a display board set at a room through remote sensing at an interval of 12 minutes. Data was collected from the display board through the pc connect software, grouped into discrete data and then calculated to represent mean wind speed, diurnal variation, daily variation, and monthly variations. The calculated averages of wind speeds at hub heights of 10m and 13m were then used to determine the wind shear exponent and surface roughness parameter of the sites. The wind shear exponents were found to be 0.92, 0.41, and 0.54 for Nyamecheo, Kisii University, and Ikobe stations, respectively, with an average of 0.64. The roughness parameter was also calculated and found to be 3.75, 1.32, and 1.96 for Nyamecheo, Kisii University (KSU), and Ikobe, respectively, with an average of 2.35.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"42 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77225585","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
The Road to a Downstream Emissions Trading System: Designing a Scheme Combining Motorist and Government Participation 通往下游排放交易体系之路:设计一个驾驶者与政府共同参与的方案
Journal of Energy Pub Date : 2019-06-02 DOI: 10.1155/2019/1047181
Fahd Mohamed Omar Al-Guthmy, Wanglin Yan
{"title":"The Road to a Downstream Emissions Trading System: Designing a Scheme Combining Motorist and Government Participation","authors":"Fahd Mohamed Omar Al-Guthmy, Wanglin Yan","doi":"10.1155/2019/1047181","DOIUrl":"https://doi.org/10.1155/2019/1047181","url":null,"abstract":"As downstream road transport has not been fully integrated into any emissions trading scheme, this paper proposes and evaluates the possibility of one by addressing the main barriers hindering its development. Based on this, a scheme which separates the “Cap” and “Trade” participation to motorists and local governments, respectively, is presented through a systematic review. We investigate how the scheme addresses the problems of cost, administrative burden, and fuel allowance allocation as they are all key factors that need equal consideration. We also justify the model’s unique structure and characteristics against the world’s largest scheme, the European Union Emissions Trading System (EU ETS), to ensure they cater to the three aforementioned issues barring its viability. It is concluded that, by amending specific policy attributes of a road-based emissions trading scheme significantly, it could be more practical both economically and administratively. Also, leveraging on existing institutional arrangements would allow for an economically feasible environment for the administration and management of such a scheme.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"55 11","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/1047181","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72367999","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Energy Consumption Analysis of a Large Building at Memorial University 纪念大学某大型建筑能耗分析
Journal of Energy Pub Date : 2019-05-12 DOI: 10.1155/2019/5243737
Almahdi Abdo-Allah, M. Iqbal, K. Pope
{"title":"Energy Consumption Analysis of a Large Building at Memorial University","authors":"Almahdi Abdo-Allah, M. Iqbal, K. Pope","doi":"10.1155/2019/5243737","DOIUrl":"https://doi.org/10.1155/2019/5243737","url":null,"abstract":"In this paper, energy consumption analysis and a process to identify appropriate models based on heat dynamics for large structures are presented. The analysis uses data from heating, ventilation, and air-conditioning (HVAC) system sensors, as well as data from the indoor climate and energy software (IDA Indoor Climate and Energy (IDA-ICE) 4.7 simulation program). Energy consumption data (e.g., power and hot water usage) agrees well with the new models. The model is applicable in a variety of applications, such as forecasting energy consumption and controlling indoor climate. In the study, both data-derived models and a grey-box model are tested, producing a complex building model with high accuracy. Also, a case study of the S. J. Carew building at Memorial University, St. John’s, Newfoundland, is presented.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"14 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83918341","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Sizing and Dynamic Modeling of a Power System for the MUN Explorer Autonomous Underwater Vehicle Using a Fuel Cell and Batteries 使用燃料电池和电池的MUN探索者自主水下航行器动力系统的尺寸和动态建模
Journal of Energy Pub Date : 2019-04-02 DOI: 10.1155/2019/4531497
Mohamed M. Albarghot, Tariq Iqbal, K. Pope, L. Rolland
{"title":"Sizing and Dynamic Modeling of a Power System for the MUN Explorer Autonomous Underwater Vehicle Using a Fuel Cell and Batteries","authors":"Mohamed M. Albarghot, Tariq Iqbal, K. Pope, L. Rolland","doi":"10.1155/2019/4531497","DOIUrl":"https://doi.org/10.1155/2019/4531497","url":null,"abstract":"The combination of a fuel cell and batteries has promising potential for powering autonomous vehicles. The MUN Explorer Autonomous Underwater Vehicle (AUV) is built to do mapping-type missions of seabeds as well as survey missions. These missions require a great deal of power to reach underwater depths (i.e., 3000 meters). The MUN Explorer uses 11 rechargeable Lithium-ion (Li-ion) batteries as the main power source with a total capacity of 14.6 kWh to 17.952 kWh, and the vehicle can run for 10 hours. The drawbacks of operating the existing power system of the MUN Explorer, which was done by the researcher at the Holyrood management facility, include mobilization costs, logistics and transport, and facility access, all of which should be taken into consideration. Recharging the batteries for at least 8 hours is also very challenging and time consuming. To overcome these challenges and run the MUN Explorer for a long time, it is essential to integrate a fuel cell into an existing power system (i.e., battery bank). The integration of the fuel cell not only will increase the system power, but will also reduce the number of batteries needed as suggested by HOMER software. In this paper, an integrated fuel cell is designed to be added into the MUN Explorer AUV along with a battery bank system to increase its power system. The system sizing is performed using HOMER software. The results from HOMER software show that a 1-kW fuel cell and 8 Li-ion batteries can increase the power system capacity to 68 kWh. The dynamic model is then built in MATLAB/Simulink environment to provide a better understanding of the system behavior. The 1-kW fuel cell is connected to a DC/DC Boost Converter to increase the output voltage from 24 V to 48 V as required by the battery and DC motor. A hydrogen gas tank is also included in the model. The advantage of installing the hydrogen and oxygen tanks beside the batteries is that it helps the buoyancy force in underwater depths. The design of this system is based on MUN Explorer data sheets and system dynamic simulation results.","PeriodicalId":30572,"journal":{"name":"Journal of Energy","volume":"106 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81015391","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信