SPIE Optical Metrology最新文献

筛选
英文 中文
Shearography as part of a multi-functional sensor for the detection of signature features in movable cultural heritaged 剪切成像作为多功能传感器的一部分,用于可移动文化遗产的特征检测
SPIE Optical Metrology Pub Date : 2007-07-19 DOI: 10.1117/12.727497
R. Groves, W. Osten, M. Doulgeridis, E. Kouloumpi, Tim Green, Stephen Hackney, V. Tornari
{"title":"Shearography as part of a multi-functional sensor for the detection of signature features in movable cultural heritaged","authors":"R. Groves, W. Osten, M. Doulgeridis, E. Kouloumpi, Tim Green, Stephen Hackney, V. Tornari","doi":"10.1117/12.727497","DOIUrl":"https://doi.org/10.1117/12.727497","url":null,"abstract":"This is one of a series of papers submitted by the Multi-Encode Project consortium (006427 (SSPI)). Shearography, a full-field speckle interferometry technique, is applied to the investigation of movable cultural heritage. For this project a portable shearography sensor was developed, with conventional sensor hardware supported by novel algorithms and instrument control software. The sensor has been used for an extensive measurement program, the purpose of which is to develop an Impact Assessment Procedure; this is to determine the capabilities of a shearography sensor in this measurement application. Data from the sensor, which shows the location of defects in the artwork, is stored in a database for future analysis and comparison. The particular advantages identified for incorporating shearography in a multi-functional sensor are the ability to measure unstable objects, such as gently vibrating canvas paintings, adjustable interferometric sensitivity and a different sensitivity parameter (displacement gradient) to the other sensors investigated. This work will assist in fulfilling the aims of the project, the detection of signature features for security purposes and the study of changes in artwork for conservation purposes.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"17 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130911645","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
Role of dynamic holography with photorefractive crystals in a multi-functional sensor for the detection of signature features in movable cultural heritage 光折变晶体动态全息技术在多功能可移动文化遗产特征检测中的作用
SPIE Optical Metrology Pub Date : 2007-07-19 DOI: 10.1117/12.727879
C. Thizy, M. Georges, M. Doulgeridis, E. Kouloumpi, Tim Green, Stephen Hackney, V. Tornari
{"title":"Role of dynamic holography with photorefractive crystals in a multi-functional sensor for the detection of signature features in movable cultural heritage","authors":"C. Thizy, M. Georges, M. Doulgeridis, E. Kouloumpi, Tim Green, Stephen Hackney, V. Tornari","doi":"10.1117/12.727879","DOIUrl":"https://doi.org/10.1117/12.727879","url":null,"abstract":"This paper is one of a series submitted by the Multi-Encode Project consortium and covers the development of holographic interferometry with dynamic photorefractive crystals. The aim of the first phase of the project is to assess the existing techniques for detection of signatures in various types of artworks. The trademark of our technique is a very high resolution in the fringe pattern. We will show the potentiality of our technique for the present application.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"227 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124506946","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Full-field high-speed optical coherence tomography system for evaluating multilayer and random tissues 用于评价多层和随机组织的全场高速光学相干层析成像系统
SPIE Optical Metrology Pub Date : 2007-07-16 DOI: 10.1117/12.726315
I. Gurov, A. Karpets, N. Margariants, E. Vorobeva
{"title":"Full-field high-speed optical coherence tomography system for evaluating multilayer and random tissues","authors":"I. Gurov, A. Karpets, N. Margariants, E. Vorobeva","doi":"10.1117/12.726315","DOIUrl":"https://doi.org/10.1117/12.726315","url":null,"abstract":"Testing the condition of art subjects plays important role in reservation of Cultural Heritage. Optical Coherence Tomography (OCT) is a promising tool for nondestructive cross-sectional evaluating internal structure of material samples like varnish layer of paintings. It is important to use high-speed OCT systems for testing subsurface structure of objects with large area. In the paper, comparison of OCT systems from viewpoint of information capacity is given to select the most appropriate OCT system variant for evaluating 3D multilayer and random tissues. The method of sub- Nyquist sampling of OCT signals is considered that is used to decrease sampling speed in a few times. To provide high noise-immunity and stability when processing OCT signals with randomly variable parameters, the Kalman filtering method has been applied for evaluating sub-Nyquist sampled OCT signals. Experimental results of evaluating materials like varnish layer of paintings are presented and discussed.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116988314","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Volumetric 3D display for visualization of archaeological samples investigated with neutron tomography 用中子层析成像研究考古样品的三维显示
SPIE Optical Metrology Pub Date : 2007-07-16 DOI: 10.1117/12.726001
V. Fiasconaro, F. Andreoli, M. Palomba, A. Papaleo, R. Rosa
{"title":"Volumetric 3D display for visualization of archaeological samples investigated with neutron tomography","authors":"V. Fiasconaro, F. Andreoli, M. Palomba, A. Papaleo, R. Rosa","doi":"10.1117/12.726001","DOIUrl":"https://doi.org/10.1117/12.726001","url":null,"abstract":"At the ENEA TRIGA research reactor (Casaccia Research Center, Rome), an equipment is available for neutron radiography applications, including radiographic image digitalization system based on a CCD camera and rotating unit for tomography applications. After the neutron-light conversion stage, the image acquisition is performed with an assembly of mirror, lenses and CCD connected to a personal computer located in the reactor room. A software package elaborates the image set performing a filtered back projection tomographic 3-D reconstruction generating a DICOM formatted data set. For visualizing 3D neutron tomography, the Perspecta Spatial 3D Visualization Platform, developed by Actuality Systems, Inc. was used.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124839508","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optical coherence tomography for varnish ablation monitoring 光相干层析成像用于清漆烧蚀监测
SPIE Optical Metrology Pub Date : 2007-07-16 DOI: 10.1117/12.725894
P. Targowski, J. Marczak, M. Gora, A. Rycyk, A. Kowalczyk
{"title":"Optical coherence tomography for varnish ablation monitoring","authors":"P. Targowski, J. Marczak, M. Gora, A. Rycyk, A. Kowalczyk","doi":"10.1117/12.725894","DOIUrl":"https://doi.org/10.1117/12.725894","url":null,"abstract":"Optical Coherence Tomography (OCT) is a new, fast-growing technique for non-contact and non-destructive imaging of semi-transparent objects. It has been recently used for diverse applications in art conservation subject - among others it is very well suited for varnish layer imaging and thus for monitoring of varnish removing process, including the laser ablation. In this study we show how to use the OCT technique to obtain the information required for the optimisation of the laser emission parameters like fluency and working regime, with respect to efficiency and safety of the ablation process. We also demonstrate application of the Spectral Optical Coherence Tomography (SOCT) for in-situ monitoring of laser ablation of varnish layer. The frames from OCT tomographic movies demonstrating dynamic processes like melting, resolidification and exfoliation of varnish layer are also presented.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129558453","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Polarimetry as tool to improve phase measurement in an amplitude modulated laser for submarine archaeological sites inspection 偏振测量法作为一种改进调幅激光相位测量的工具,用于海底考古遗址检测
SPIE Optical Metrology Pub Date : 2007-07-16 DOI: 10.1117/12.725320
L. Bartolini, L. D. Dominicis, M. D. Collibus, G. Fornetti, M. Francucci, M. Guarneri, E. Paglia, Claudio Poggi, R. Ricci
{"title":"Polarimetry as tool to improve phase measurement in an amplitude modulated laser for submarine archaeological sites inspection","authors":"L. Bartolini, L. D. Dominicis, M. D. Collibus, G. Fornetti, M. Francucci, M. Guarneri, E. Paglia, Claudio Poggi, R. Ricci","doi":"10.1117/12.725320","DOIUrl":"https://doi.org/10.1117/12.725320","url":null,"abstract":"The propagation of polarized laser beams in turbid water is a subject of relevant interest in the field of underwater quantitative visualization with active sensors like amplitude modulated laser systems. In such devices, target range determination is based on the measurement of the phase difference ΔΦ between the fraction of the amplitude modulated laser beam reflected by the target and a reference signal. As water turbidity increases, the laser radiation backscattered from the water column shined by the sounding laser beam gives rise to an optical background with detrimental effects on the accuracy of range measurement. In this paper we analyze the possibility to increase the apparatus accuracy with a polarimetric technique based on the adoption of polarized laser radiation and polarization selective detection scheme for improving the underwater imaging of real scenes (e.g. archaeological sites). The method fully takes advantages of the different polarization properties of the laser radiation backscattered by turbid water and of the Lambertian component diffusively reflected by the target as described by the associated Mueller matrices. Measurements have been performed by adopting both a co-polarized and cross-polarized detection scheme with linearly and circularly polarized laser radiation. Various degrees of turbidity were realized by adding, as diffusive element, skim milk to water in order to obtain different scattering conditions. The effect of the transition from Rayleigh to Mie scattering regime on phase accuracy determination has been investigated together with the role played by high order scatterings as the medium approaches the optical thickness condition.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128064992","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Defect detection of wall paintings in the Château de Versailles using TV-holography and IR thermography 利用电视全息和红外热成像技术检测凡尔赛宫壁画的缺陷
SPIE Optical Metrology Pub Date : 2007-07-16 DOI: 10.1117/12.725875
J. Chambard, A. Roche
{"title":"Defect detection of wall paintings in the Château de Versailles using TV-holography and IR thermography","authors":"J. Chambard, A. Roche","doi":"10.1117/12.725875","DOIUrl":"https://doi.org/10.1117/12.725875","url":null,"abstract":"Monuments are continuously submitted to external events like water infiltration or condensation, temperature variation, soil instability, that lead to internal damage of the structure itself as well as of its surfaces. Wall paintings are then submitted to stresses that may cause cracks, internal de-lamination of the plaster or de-bonding between canvas and plaster. In the frame of the restoration of the \"galerie des glaces\" in the \"château de Versailles\", TV-Holography and IR Thermography have been used to investigate the wall paintings of the vault. The surfaces to control were either direct paintings on the plaster or paintings on canvas backed on the plaster. IR Thermography for art work and in particular for wall paintings has only recently been used. The technique allows to record transient temperature maps, when slightly heating the surface during a short time. Then, nonhomogeneities in the conductive heat transfer are related to de-bonding or de-lamination. The time parameter gives information on the depth of the defect. A calibration procedure has to be carried out to ensure reliable defect detection. Speckle interferometry is a Non Destructive Testing technique that is currently used in industry. For the wall paintings, we have used TV-Holography associated with a continuous wave laser. The technique allows, 13 metres away from the surface, to detect parts of the paintings that were vibrating due to an acoustic excitation. The control processes based on these two technologies is detailed as well as the results obtained and a comparison with manual investigation is done.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122807008","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Laser induced breakdown spectroscopy in paintings and sculptures research 激光诱导击穿光谱在绘画和雕塑中的研究
SPIE Optical Metrology Pub Date : 2007-07-05 DOI: 10.1117/12.726151
A. Sarzyński, W. Skrzeczanowski, J. Marczak
{"title":"Laser induced breakdown spectroscopy in paintings and sculptures research","authors":"A. Sarzyński, W. Skrzeczanowski, J. Marczak","doi":"10.1117/12.726151","DOIUrl":"https://doi.org/10.1117/12.726151","url":null,"abstract":"Application of Laser Induced Breakdown Spectroscopy (LIBS) for investigation of chemical constitution and stratigraphy of artworks, and metallic objects with multilayer structures is described in the paper. Physical phenomena accompanying LIBS investigations, especially temporal evolution and spectral lines broadening are described. Operational characteristics of experimental equipment are shown. Results obtained with use of two different echelle spectrometers are compared. Pigments used in oil paintings are analyzed and analysis results are presented. Experimental results of measurements of various objects like paintings, sculptures and artifacts are shown. Works on dating of investigated paintings are described.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131082065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Simultaneous acquisition of 3D shape and color texture from large frescoed areas 同时获取大型壁画区域的三维形状和颜色纹理
SPIE Optical Metrology Pub Date : 2007-07-05 DOI: 10.1117/12.725869
M. Caldon, M. Fedel, Luca Poletto, N. Brusco, G. Cortelazzo, A. Paviotti
{"title":"Simultaneous acquisition of 3D shape and color texture from large frescoed areas","authors":"M. Caldon, M. Fedel, Luca Poletto, N. Brusco, G. Cortelazzo, A. Paviotti","doi":"10.1117/12.725869","DOIUrl":"https://doi.org/10.1117/12.725869","url":null,"abstract":"We present the recent results obtained by a system which measures both 3D shape and multispectral texture of artistic and architectural cultural assets. The system consists on a rangefinder device which acquires the range and a visible scanning spectrograph for colour texture analysis. This technique is applied to the acquisition of the cycle of Stories of Maria, a frescoed lateral chapel painted by Girolamo Tessari in 1523-1526 located in the church of S. Francesco in Padua (Italy).","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114306843","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
3D acquisition and modeling for flint artefacts analysis 火石人工制品分析的三维采集与建模
SPIE Optical Metrology Pub Date : 2007-07-05 DOI: 10.1117/12.726149
B. Loriot, Y. Fougerolle, C. Sestier, R. Seulin
{"title":"3D acquisition and modeling for flint artefacts analysis","authors":"B. Loriot, Y. Fougerolle, C. Sestier, R. Seulin","doi":"10.1117/12.726149","DOIUrl":"https://doi.org/10.1117/12.726149","url":null,"abstract":"In this paper, we are interested in accurate acquisition and modeling of flint artefacts. Archaeologists needs accurate geometry measurements to refine their understanding of the flint artefacts manufacturing process. Current techniques require several operations. First, a copy of a flint artefact is reproduced. The copy is then sliced. A picture is taken for each slice. Eventually, geometric information is manually determined from the pictures. Such a technique is very time consuming, and the processing applied to the original, as well as the reproduced object, induces several measurement errors (prototyping approximations, slicing, image acquisition, and measurement). By using 3D scanners, we significantly reduce the number of operations related to data acquisition and completely suppress the prototyping step to obtain an accurate 3D model. The 3D models are segmented into sliced parts that are then analyzed. Each slice is then automatically fitted by mathematical representation. Such a representation offers several interesting properties: geometric features can be characterized (e.g. shapes, curvature, sharp edges, etc), and a shape of the original piece of stone can be extrapolated. The contributions of this paper are an acquisition technique using 3D scanners that strongly reduces human intervention, acquisition time and measurement errors, and the representation of flint artefacts as mathematical 2D sections that enable accurate analysis.","PeriodicalId":299482,"journal":{"name":"SPIE Optical Metrology","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122400740","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书