{"title":"A control method for stable operation of distributed generation resources with active power filter capability","authors":"S. Seyedalipour, G. Gharehpetian","doi":"10.1109/EPDC.2016.7514811","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514811","url":null,"abstract":"In this paper, a control scheme based on Lyapunov's stability theory is proposed for connection of distributed generation (DG) resources to electrical grids via power electronic converters. The dynamic analysis of the DG system is first carried out, and then the proper switching state functions of grid-interfacing converter are obtained for stable operation of DG unit. Unlike classical control techniques, the proposed method does not need proportional-integral (PI) regulators to control interfaced converter. By determining the suitable current references of the DG unit, the harmonic, reactive, and active currents of loads are fast provided. In consequence, grid currents will be linear and in phase with voltages of points of common coupling (PCC), when the maximum power transferred from DG resources to network is less than requested power of grid-connected loads. The simulation results validate the effectiveness of the proposed control method.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126952498","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Incentive cloud-based demand response program using game theory in smart grid","authors":"M. Yaghmaee, B. Barabadi, S. Alishahi, M. Zabihi","doi":"10.1109/EPDC.2016.7514800","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514800","url":null,"abstract":"The demand for more electricity is growing with the increasing trend in using more electrical devices. Therefore besides allocating more sources of energy to generate electricity, many utility companies try hard to make sure that they can manage the demand for more electricity by the adaptation of well-established demand response program. Demand response programs bring proved benefit to grid operation and yields market efficiency by incorporating customers' decision. In this paper, we propose an incentive cloud-based demand response program utilizing game theory in customers' side. In contrast to other methods which include a bargaining process between utility and customers, the proposed model uses resource allocation to offer a fair incentive price to each user. In this manner, we encourage users to take part in incentive-based demand response program. The utility will also profit from this process by allocating price individually to each user. Numerical results confirm that the proposed work is successful to achieve its goals.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"87 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114949689","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effects of Phasor Measurement Unit on correlation of WLS state estimation results","authors":"M. Davoudi","doi":"10.1109/EPDC.2016.7514798","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514798","url":null,"abstract":"This paper investigates the effects of Phasor Measurement Unit (PMU) on the correlation of Weighted Least Squares (WLS) power system state estimator's results. For this aim an approach is introduced to perform this analysis in real power grids considering the line parameters and measurement uncertainty. This approach is based on Monte Carlo simulations and is used to realize how much inclusion of PMU data in the measurements will affect the state estimator's correlation behavior whereas the network parameters are subjected to different quantities of uncertainties for a given measurement uncertainty. The approach is simulated on the IEEE 30-Bus test case and to illustrate the correlation of the state estimation results, the estimates correlations are computed versus different amounts of network line parameters uncertainty for one set of PMU locations. The novelty of this analysis lies behind the point that how PMUs will impact the estimates correlations in a realistic network with uncertain parameters. This analysis belongs to the extensive research on the effects of PMU on realistic power system state estimation that has initiated by the author in 2009.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128667404","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transition from fossil fuels power plants toward Virtual Power Plants of distribution networks","authors":"S. Pazouki, M. Haghifam, Samira Pazouki","doi":"10.1109/EPDC.2016.7514787","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514787","url":null,"abstract":"One of the most significant challenges of metropolitan cities is producing the exceedingly growing demands of customers. To do this, fossil fuels power plants need to be established and transmission lines are required to be expanded. Founding fossil fuels power plants are along with more emission production and expenses. Worldwide smart grid project obligates all the countries to provide some parts of their energy demands through renewable energy resources. Distributed Energy Resources (DERs): Wind Turbine (WT), Combined Heat and Power (CHP), Energy Storage (ES), and Demand Response programs (DR) are taken into account as the outstanding technologies of distributed generations. Interconnection of DERs to electric distribution networks constructs Virtual Power Plants (VPPs) with slighter emission and lower expenses. In this paper, effectiveness of different DERs within the VPPs is investigated in reducing emission, expenses, and technical challenges of electric distribution networks. An Energy Hub (EH) is modeled to portray the problem. GAMS software is employed to resolve the problem. Simulation results manifest the operation costs and energy consumption reduction on electric distribution networks by utilization of the different aforementioned technologies within the VPPs. The results also demonstrate effects of load and loss factors as well as emission production through employment of the different DERs within VPPs.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130093090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. kazemi, Mehdi Zabihi Shesh Poli, Aliakbar Shahbahrami, Ebrahim Gholinejad
{"title":"Stabilizing distribution network during peak load by means of distributed generations (case study: Nowshahr City located in Mazandaran-Iran)","authors":"M. kazemi, Mehdi Zabihi Shesh Poli, Aliakbar Shahbahrami, Ebrahim Gholinejad","doi":"10.1109/EPDC.2016.7514792","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514792","url":null,"abstract":"Electricity production during peak load compared to off-peak imposes additional cost to the ministry of power whereas power loss reaches to its maximum. In recent years one of the main problems in Iran's distribution network has been excessive voltage drop in some of its 20 KV feeders during peak load so that the distribution company has to apply interruptions to some costumers. In this paper in order to solve the mentioned problem, distributed generation (DG) with optimum size and location using intelligent algorithms is introduced. Stability of Nowshahr city's feeders located in Mazandaran province-Iran, due to its connection to the seaport and city's tourist, is of great importance. Localization and sizing of DGs are investigated using three scenarios (1, 2, 3 DGs) with regard to the limitations on DGs penetration index. In this paper reliability parameters, SAIFI, SAIDI and ENS are calculated and compared before and after DG installation. In order to have an operational plan, low load and short circuit analysis along with return of investment assuming that all DGs are in form CHP, is carried out.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131621299","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A three-phase/level unity-power-factor AC-AC converter for wind energy conversion systems","authors":"Omid Alavi, Abbas Hooshmand Viki","doi":"10.1109/EPDC.2016.7514793","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514793","url":null,"abstract":"Supplying a motor using a wind turbine is one of the most important issues in the field of renewable energy. Here, we introduce a three-phase, unity-power-factor converter as a solution to feed motors with a fixed-speed wind turbine. The converter consists of a Vienna rectifier and a three-level inverter linked together, and the converter can be thought of as a boost converter. We use hysteresis-based control to control the rectifier, and we use space vector pulse width modulation to control the inverter. We employ simulations to verify our theoretical results, and our findings show that the optimum switching frequency to ensure the best total harmonic distortion (THD) is 7 kHz. The minimum current and voltage THD are 0.28% and 25.37%, respectively.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115998092","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Arc Flash decreasing by using re-closer relay on a 20kV network","authors":"M. Aliabadi, Hassan Farrokhi","doi":"10.1109/EPDC.2016.7514802","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514802","url":null,"abstract":"In this paper, the role of re-closer relay in the case of decreasing arc flash hazard on a power system network is presented. An arc flash analysis performs on system to identify the Personal Protective Equipment (PPE) category, so solutions for PPE category optimization are studied. The results emphasize that by applying re-closer relay, PPE category are optimized and changed to better (lower) range and covers reference standards requirements. Also incident energy reduces and Arc Flash Boundary (AFB) limited to lower distance which are definitely mandatory and vital for the safety of persons who are doing maintenance and work on/around hot lines. Simulation is done by intelligent simulating software like Electrical Transient and Analysis Program (ETAP).","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"94 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124660575","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Gholinezhad, N. Aghli, H. Ghorbanpanah, M. Pourhossein
{"title":"A new control strategy for series active filter to improve low-frequency oscillations damping","authors":"J. Gholinezhad, N. Aghli, H. Ghorbanpanah, M. Pourhossein","doi":"10.1109/EPDC.2016.7514801","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514801","url":null,"abstract":"When power systems are expanded and connected together with weak tie lines, the low-frequency oscillations are increased and the stability margin of the power system decreases. Therefore, when designing the transmission and distribution systems to be used, it is necessary to maintain the dynamic stability of the power system, and to make sure to have the most possible stability margin. Series active power filter (SAPF) is connected in series with power distribution lines. SAPF can control power flow very effectively and can inject series inductive or capacitive voltages into the line. In this paper, a new control strategy based on voltage measurement for the SAPF is proposed. The commonly used strategy for SAPF is based on line current measurement; consequently, the injected voltage is in quadrature with the line current. But in the proposed strategy, the injected voltage is in quadrature with the ac voltage at the point of common coupling (PCC) of SAPF. With modifications done in the proposed strategy, compared with the conventional control method, it can be adjusted easily to control the power flow of the distribution line. The simulation is performed in single-machine and multi-machine power systems. The analysis of the results under different disturbances show that the proposed strategy has an appropriate response with respect to the changes in the system states and it is relatively faster in damping power system oscillations, compared with the conventional strategy.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124793900","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Multi-source power system FOPID based Load Frequency Control with high-penetration of Distributed Generations","authors":"H. Shayeghi, A. Molaee, K. Valipour, A. Ghasemi","doi":"10.1109/EPDC.2016.7514796","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514796","url":null,"abstract":"This paper presents a Fractional Order Proportional-Integral-Derivative (FOPID) controller optimized using Social Spider Optimization (SSO) algorithm to Load Frequency Control (LFC) of a two-area multi-source power system in the presence of Distributed Generations (DGs). Here, the effect of DGs consist of wind and diesel power plants for damping frequency deviation of two-area multi-source power system including thermal, hydro and gas units considering nonlinearities such as generation rate constraint and governor dead band has been investigated. The FOPID controller has three main control parameters as known gain, fractional orders of integrator and derivative part that provide the better performance in comparison with the PID controller. On the other hand, to achieve the good performance in the power system, tuning of these parameters is very important. Therefore, the SSO algorithm has been used to optimal tuning of the FOPID based LFC controller. One of the important specifications of the employed algorithm is that it can balance the local and global solutions in the search space that cause to overcome the local optimal and premature convergence. Also, a High Voltage Direct Current link (HVDC) is used to improve the dynamic performance of the LFC task. Finally, the proposed controller has been applied on a two case studies and analyzed based on investigated performance criteria. Results show the good effect of DGs for the solution of LFC task and enhancing system performance characteristics under different operating conditions and considering system nonlinearities.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122925643","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Increasing the renewables share in discos power provision: An optimal charging/discharging collaboration through EV fleets","authors":"Amir Hamidi, D. Nazarpour, S. Golshannavaz","doi":"10.1109/EPDC.2016.7514789","DOIUrl":"https://doi.org/10.1109/EPDC.2016.7514789","url":null,"abstract":"This paper investigates the promising effects of electric vehicle (EV) fleets charging/discharging patterns on increasing the renewable share on electrification of modern distribution companies (Discos). As a technical flaw, the voltage violation to higher values than the permissible range averts the elevated generation of photovoltaic (PV) units and hence brings about economical and environmental detriments. As a promising countermeasure, it is shown that the vehicle to grid (V2G) functionality of EV fleets enables a collaborative charging/discharging framework to suitably augment the PV share in power provision task. In the outlined theme, a successful scheduling approach necessitates a comprehensive analysis on important factors such as system losses and battery degradation costs. Hence, the founded approach accommodates these issues to yield in a more efficient energy management of EV fleets in V2G paradigm. The optimization problems lies within a non-liner programming (NLP) fashion which is tackled based on genetic algorithm (GA). Extensive numerical analyses are carried out to examine the V2G functionality in enhancing the PVs share in clean energy provision. The obtained results are encouraging.","PeriodicalId":296836,"journal":{"name":"2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125658452","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}