B. Leao, T. Timmers, J. van der Lei, E. V. van Mulligen
{"title":"HEARTVIEW-an object-oriented knowledge base to support clinical research in cardiology","authors":"B. Leao, T. Timmers, J. van der Lei, E. V. van Mulligen","doi":"10.1109/CIC.1990.144171","DOIUrl":"https://doi.org/10.1109/CIC.1990.144171","url":null,"abstract":"HEARTVIEW-a model to represent the data in a medical record-is presented. This model is based on the assumption that there is a general structure in the medical record. This general structure was modeled as a five-layered structure and implemented in an object-oriented environment. HEARTVIEW is an independent module of the medical workstation 2000 (MW2000), a project under development. The main goal of HEARTVIEW is to offer support for clinical research in cardiology. The description of the model and its implementation are presented.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"127 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116329329","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
L. Vogt, M. Sigmund, C. Kirkpatrick, J. Silny, H. Volker, G. Rau, P. Hanrath, S. Effert
{"title":"Non-invasive detection of acute rejection after cardiac transplantation by means of body surface potential mapping","authors":"L. Vogt, M. Sigmund, C. Kirkpatrick, J. Silny, H. Volker, G. Rau, P. Hanrath, S. Effert","doi":"10.1109/CIC.1990.144263","DOIUrl":"https://doi.org/10.1109/CIC.1990.144263","url":null,"abstract":"Results are presented of monitoring 16 patients after orthotopic heart transplantation (OHT). In 377 examinations the grade of rejection was determined by endomyocardial biopsy (EMB). The QRS voltage was measured by noninvasive body surface potential mapping (BSPM) within 4 hours of EMB. Sixty-three acute rejections necessitating additional medical therapy, graded A-3b or A-4 according to the Hannover classification scheme, were detected by EMB. Only 13 of these acute rejections could be identified by QRS reduction in the standard electrocardiogram (ECG) (sensitivity of 21%). However, 48 of them showed positive BSPM-ECG. In 93 of 314 negative biopsies BSPM showed a significant drop in voltage, indicating BSPM was false positive. Thus the sensitivity of BSPM to detect acute rejection was 76% with a specificity of 70%. Only 22 of 200 BSPM-ECG of normal subjects shows a significant drop of QRS voltage (specificity of 89% in the control group). It is concluded that QRS voltage reduction in a localized area measured by BSPM is a useful screening method for moderate or severe acute rejection.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124083238","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Teaching physiology through simulation of hemodynamics","authors":"T. Davis, R. Mark","doi":"10.1109/CIC.1990.144303","DOIUrl":"https://doi.org/10.1109/CIC.1990.144303","url":null,"abstract":"A user-friendly interface to a mathematical model for teaching cardiovascular physiology is developed. The underlying model, a lumped-parameter approximation of cardiovascular hemodynamics and control, 'comes to life' in this real-time simulation. Students interact with the model through the X Window System interface, using the mouse to create continuously updating, realistic graphs of blood pressure, volume, or flow for any of the compartments. Students perform experiments on a 'virtual patient' in order to understand the intrinsic properties of the system as it responds dynamically to normal stresses and pathological insults. Instructors may set up patient cases with simulated diseases and ask students to examine the hemodynamics in order to make a diagnosis. Using this program, students are able to explore the function of the cardiovascular system in greater depth than would be possible through conventional teaching methods.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130111226","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study on the influence of a noisy environment on the ECG correlation dimension determination; possible use for noise estimation","authors":"A. Casaleggio, M. Morando, S. Ridella","doi":"10.1109/CIC.1990.144254","DOIUrl":"https://doi.org/10.1109/CIC.1990.144254","url":null,"abstract":"It is shown how the determination of the correlation dimension (D/sub 2/), an algorithm which allows the estimation of a nonlinear system degrees of freedom, is affected by the presence of noise. The poor accuracy in computing D/sub 2/ is related to the noise fraction of the signal measurement. A very simple empirical way to adjust the D/sub 2/ value is presented. Some preliminary results on a rough way for the noise fraction estimation are given. This study has been done mainly on a Henon attractor, and D/sub 2/ adjustments have been tried on electrocardiogram (ECG) signals, yielding D/sub 2/ values ranging between 1 and 2, in healthy subjects.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130212247","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Efficient generation of 3-D images and off-axis projections using a PC-based parallel-processing subsystem","authors":"S. Cannon, S. J. Allan","doi":"10.1109/CIC.1990.144237","DOIUrl":"https://doi.org/10.1109/CIC.1990.144237","url":null,"abstract":"A simple and inexpensive parallel-processing subsystem for the rapid generation and display of 3-D cardiac images from 2-D computed tomography and magnetic resonance imaging planes is presented. Parallel versions of algorithms for image interpolation, surface tracking, and 3-D image rendering were developed and implemented using a network of four INMOS transputers which are hosted by a PC-type computer. The subsystem accepts a stack of arbitrarily spaced 2-D image planes and efficiently produces a surface-shaded 3-D orthoprojection image which can then be arbitrarily rotated for viewing. It is concluded that this transputer-based subsystem hosted by a simple PC computer represents a cost-effective alternative to Pixar-style image processing workstations and is capable of generating high-resolution 3-D images in a reasonable amount of time.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134132622","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High frequency ECG during reperfusion therapy of acute myocardial infarction","authors":"S. Abbound, J. Leor, M. Eldar","doi":"10.1109/CIC.1990.144232","DOIUrl":"https://doi.org/10.1109/CIC.1990.144232","url":null,"abstract":"The very high-frequency components of the QRS complex are examined to test their ability to detect effects of reperfusion therapy of acute myocardial infarction using thrombolytic agents. Surface electrocardiogram (ECG) waveforms from the standard lead V/sub 5/ were averaged (128 waveforms) 15 and 90 minutes after the administration of the thrombolytic agent. The averaged waveforms from each time segment were then bandpass-filtered between 150 and 250 Hz using the fast-Fourier-transform algorithm and were used to compute the root-mean-square (RMS) voltage of the filtered QRS complex. It is found that after successful reperfusion, when coronary blood flow is reestablished, the RMS voltage of the high frequency QRS complexes increases. In patients with unsuccessful reperfusion, the RMS voltage decreases. These changes in the high frequency QRS complex may be related to salvaging myocardium and may provide useful information about the reperfusion of acute myocardial infarction.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134401543","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Frequency analysis: a potential method to differentiate ventricular fibrillation of various etiologies","authors":"P. Hsia, S. Jolly, W. Reeves, R. Mahmud","doi":"10.1109/CIC.1990.144270","DOIUrl":"https://doi.org/10.1109/CIC.1990.144270","url":null,"abstract":"As ventricular fibrillation (VF) induced by alternating current (AC) is commonly used to replace a spontaneous VF during fibrillator implant, it is desirable to determine if loss of signal power could differentiate between VF induced by different methods. Using fast frequency transform analysis and a power spectral estimation method, the power loss in each frequency band (25 Hz per band) was examined over time during prolonged uninterrupted VF waveform in a canine model. A total of 15 VFs induced by fixed AC current (AC-VF) n=6, spontaneous post-ischemia (S-VF) n=6 and potassium chloride induced (KCL-VF) n=3 were tested in a canine model. In the AC-VF and S-VF, the power of the lower band (1-25 Hz) remained constant, whereas there was significant power loss (3.12+or-0.48, mean standard deviation) in 26-125-Hz bands during the initial 135+or-12 sec (p<0.01) and a plateau thereafter. However, in S-VF as compared to AC-VF, a greater (3.56+or-0.55 vs 2.68+or-0.42) and faster (126+or-13.27 sec vs 146+or-11.22 sec, p<0.01) loss of signal power was observed in the frequency bands 51-125 Hz.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134555700","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"3-D reconstruction of the left ventricle using the Tilt Echo technique","authors":"Rutvik H. Desai, J. Buckey","doi":"10.1109/CIC.1990.144312","DOIUrl":"https://doi.org/10.1109/CIC.1990.144312","url":null,"abstract":"A reconstruction algorithm used in conjunction with the Tilt Echo technique is presented. It involves an intermediate step of filtering. There is no need to extract the boundaries of the structure being imaged, which leads to a fast and efficient reconstruction system. Using image processing techniques, the acquired images are first filtered in order to reduce the noise and hence improve the signal-to-noise ratio. The regional median filtering process helps to further improve the quality of the images. The weights chosen for the mapping have shown reliable results and provided accurate reconstruction of image planes.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131758528","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sandra J. Hewett, J. Schwanke, L. Köhler, P. Jensch, G. Reil, H. Niemann
{"title":"Multimedia communication with ISDN-technologies-applications in radiology and cardiology departments","authors":"Sandra J. Hewett, J. Schwanke, L. Köhler, P. Jensch, G. Reil, H. Niemann","doi":"10.1109/CIC.1990.144195","DOIUrl":"https://doi.org/10.1109/CIC.1990.144195","url":null,"abstract":"The Integrated Services Digital Network (ISDN) is a public network standard that provides worldwide end-to-end digital communication for voice and all types of digital data. It provides the users with a large number of services and the flexibility to easily modify the services they receive as their communication needs grow and change. The advantages of the ISDN technology for medical users by supporting them with integrated image/voice/data information are discussed. A network model for in-house and remote ISDN communication of integrated multimedia information is described, the performance issues associated with an experimental distributed multimedia manipulation system are examined, and its applicability in a number of possible operating scenarios is addressed.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132825069","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Di Rienzo, P. Castiglioni, G. Parati, A. Ramirez, A. Pedotti
{"title":"Short and long term variability of systolic blood pressure and pulse interval in intact and baroreceptor denervated cats","authors":"M. Di Rienzo, P. Castiglioni, G. Parati, A. Ramirez, A. Pedotti","doi":"10.1109/CIC.1990.144185","DOIUrl":"https://doi.org/10.1109/CIC.1990.144185","url":null,"abstract":"The effects of the surgical opening of the baroreflex loop on the spectral components of systolic blood pressure (SBP) and pulse interval (PI) variability in 8 unrestrained cats are analyzed. In each cat, the spectral characteristics were estimated from intraarterial blood pressure tracings recorded before and after surgical sino-aortic baroreceptor denervation (SAD). The analysis focused on two different spectral regions. The first region included spectral components having periods ranging from 1.6 to 40 seconds, while the second region (partially overlapping the first one) included components with periods from 10 seconds up to 1.5 hours. The opening of the baroreflex loop caused nonhomogeneous effects on the various components of SBP and PI variability. These findings evidence a differentiated involvement of the baroreceptors in controlling SBP and PI variations characterized by different time constants.<<ETX>>","PeriodicalId":296262,"journal":{"name":"[1990] Proceedings Computers in Cardiology","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128838288","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}