{"title":"Adaptive data distribution technique for enhancing MB-OFDM UWB link performance in detect and avoid environments","authors":"A. Rateb, S. Yusof, N. Fisal","doi":"10.1504/IJUWBCS.2011.038631","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2011.038631","url":null,"abstract":"Detect-and-avoid (DAA) mechanisms were developed to minimise potential interference caused by ultra wideband (UWB) systems to in-band active narrowband links. Interference is reduced by minimising emitted power in overlapping bands to create a spectral notch, which provides a certain level of isolation between both systems. Although it has been proved that this procedure deteriorates UWB link performance significantly, no research suggested any scheme to mitigate it. In this paper, we introduce the adaptive data distribution (ADD) technique, which we developed to enhance UWB link performance upon employment of DAA. ADD technique is confined to the physical layer and is fully transparent to the MAC sub-layer. Results have shown a significant reduction in error rates that could provide an SNR gain of at least 4 dB for most covered scenarios. In addition, ADD technique renders performance less sensitive to transmission mode variation and augments its coexistence capability by enabling a UWB device to safely notch 16-55% of its bandwidth.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131774335","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ultra wide bandwidth indoor channel model based on measurements and physical approach","authors":"Rachid Saadane, D. Aboutajdine","doi":"10.1504/IJUWBCS.2011.038633","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2011.038633","url":null,"abstract":"In this work, using a physic approach, which based on an analysis of physical propagation phenomenon like diffraction and reflection versus frequency band and the nature of material, we propose a new UWB channel statistical model. In particular we describe UWB channel delays and taps statistics. This analysis is done based on measurements campaign carried out at Eurecom Institute and provided over channel bandwidth from 3 to 9 GHz in different environments. Then we present a novel UWB channel model based on physical propagation effects and UWB channel measurements. A mathematical description of the model is discussed and the corresponding extraction parameter is p presented using a SAGE algorithm. Our proposed model gives a good fit to measurement data and it is easy to implement. Other features of this approach also are discussed.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133549511","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Packet loss-ratio based scheduler: an adaptive scheduling scheme to increase the number of multimedia applications in WLAN","authors":"M. Jibukumar, R. Datta, P. Biswas","doi":"10.1504/IJUWBCS.2011.038634","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2011.038634","url":null,"abstract":"The reference scheduler in IEEE 802.11e fails to maintain the goal of quality of service (QoS) support and high network efficiency simultaneously. In this paper we investigate channel access schemes to increase the number of multimedia applications in wireless local area network (WLAN) while maintaining the QoS requirements. We have developed a scheduling scheme, named as packet loss-ratio based scheduler (PLS) that takes into account the packet losses occurred while allotting the transmission time to a multimedia stream. To implement this scheme the access point (AP) requires only the queue size information and can be implemented within the format of IEEE 802.11e. The simulation results show that the PLS can accommodate more number of traffic streams and can also randomise the packet loss from a traffic stream, which is a requirement for multimedia coder-decoders (CODECs) to conceal the distortion.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"55 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129508847","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Low complexity RAKE receiver for TH-based multiuser UWB system with realistic UWB indoor channel","authors":"H. Soni, U. Desai, S. Merchant","doi":"10.1504/IJUWBCS.2011.038637","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2011.038637","url":null,"abstract":"We have considered multiuser communication scenario with ultra wideband (UWB) communication. UWB device is transmitting the data by time hopping (TH)-based system, TH-PPM, TH-PAM and DS-UWB. The UWB device is transmitting data over multipath rich channel model recommended by IEEE 802.15.3a working group. This channel model is based on Saleh-Valenzuela model. For better performance at receiver side, adaptive equaliser is required; this increases the complexity of receiver. Here we have considered the RAKE receiver for TH-based UWB system. This RAKE receiver structure is not a conventional RAKE, but it is pre-RAKE structure. In this case, we have evaluated performance of system by considering the RAKE receiver at the transmitter side. Here we have assumed the condition that channel sounding is available before transmission for quasi static UWB channel. Based on this knowledge RAKE fingers are selected for pre-RAKE. UWB channel is multipath rich channel so full RAKE adds more complexity in receiver and hence put limitation on effective data rate. Here we have considered low branch RAKE receiver. Performance of the system model is evaluated with realistic UWB channel model.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123187814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Harri Viittala, Begum N. Nahar, M. Hämäläinen, J. Iinatti
{"title":"Medical applications adapting ultra wideband: a system study","authors":"Harri Viittala, Begum N. Nahar, M. Hämäläinen, J. Iinatti","doi":"10.1504/IJUWBCS.2010.034305","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2010.034305","url":null,"abstract":"In order to find the best solution of physical layer for medical wireless body area network (WBAN), two single-band ultra wideband (UWB) systems are studied, i.e., direct sequence ultra wideband (DS-UWB) and ultra wideband frequency modulation (UWB-FM). UWB is considered to be one of the most feasible techniques among those that can be applied to medical WBAN since it provides low power consumption, simple transceiver structure and good coexistence characteristics due to a low power spectral density. The simulation results indicate that UWB-FM has better performance than non-coherent DS-UWB in overall. It was expected that coherent DS-UWB with multiple rake fingers gives the best results, and this was justified by the simulation results.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129776586","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jianqi Teo, Yifan Chen, C. Soh, E. Gunawan, K. Low, T. Putti, Shih-Chang Wang
{"title":"An overview of radar based ultra wideband breast cancer detection algorithms","authors":"Jianqi Teo, Yifan Chen, C. Soh, E. Gunawan, K. Low, T. Putti, Shih-Chang Wang","doi":"10.1504/IJUWBCS.2010.034308","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2010.034308","url":null,"abstract":"Breast cancer is the most common cancer in women in almost all countries around the world, and is one of the most common non-infective causes of death. Mammography, which uses ionising radiation, is the only early breast cancer screening technique proven to reduce breast cancer mortality in randomised controlled clinical trials. However, screening mammography is expensive, technically demanding and requires a high level of clinical expertise. It cannot be performed in general medical clinical settings readily. Ultra wideband (UWB) or microwave breast screening has the potential to be a safe, accurate and easy-to-use technique for breast disease detection that is more effective than routine clinical palpation or breast self-examination. Ultra wideband breast cancer detection algorithms have been researched by several groups for over a decade, with numerous algorithms reported. This paper serves to give an overview of existing algorithms for UWB breast cancer detection.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122261970","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Ostadrahimi, S. Noghanian, L. Shafai, A. Zakaria, Cameron Kaye, J. Lovetri
{"title":"Investigating a double layer Vivaldi antenna design for fixed array field measurement","authors":"M. Ostadrahimi, S. Noghanian, L. Shafai, A. Zakaria, Cameron Kaye, J. Lovetri","doi":"10.1504/IJUWBCS.2010.034309","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2010.034309","url":null,"abstract":"Vivaldi antenna is widely known as a broadband antenna. In this paper, we investigate a modified Vivaldi antenna with improved cross polarisation working in the ultra-wideband (UWB) frequency range (3.1-10.6 GHz) to be used as multiple probes for microwave tomography system. Our study includes investigation of radiation characteristics of the antenna, antenna design steps, fabrication sensitivity effects on the antenna performance and proposing and implementing a twenty-four antenna element system for fast data acquisition, including a novel method for frequency selection in microwave tomography applications. We also studied the fidelity parameter of the antennas inside the twenty-four element setup. The mutual coupling of adjacent elements, in spite of close proximity, is less than -17dB and fidelity variations for the antennas located in front of transmitter are less than 10%.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122248707","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Experiences on bio-medical sensing using ultra wideband communications and radar technology","authors":"Carlos G. Bilich","doi":"10.1504/IJUWBCS.2010.034306","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2010.034306","url":null,"abstract":"The aim of this work is to study and report some experimental results on the application of ultra wideband (UWB) technology to perform bio-medical sensing and vital signs monitoring in humans. Among the numerous signals that can be measured, the heart rate (HR) was chosen as the first objective due to its importance. The research is pointed towards the development of a technique that can allow both, radar sensing and communications using the same UWB transceiver. Such a sensor could use UWB radar principles to measure the heart beat rate and UWB communication standards to transmit these measurements. A readily available commercial transceiver with no hardware adaptations was used to solve for the physical layer. Wavelets and super-resolution techniques were used for signal processing the echo response achieving a sensing range of 84 cm. Having sensors with such 'duo' properties can make them ideal nodes for wearable computing, as well as sensor and body area networks.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115797408","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Taparugssanagorn, C. Pomalaza-ráez, A. Isola, R. Tesi, M. Hämäläinen, J. Iinatti
{"title":"UWB channel modelling for wireless body area networks in a hospital","authors":"A. Taparugssanagorn, C. Pomalaza-ráez, A. Isola, R. Tesi, M. Hämäläinen, J. Iinatti","doi":"10.1504/IJUWBCS.2010.034304","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2010.034304","url":null,"abstract":"This paper describes an experimental study of the ultra wideband (UWB) wireless body area network (WBAN) channel in a hospital environment. The measured data are used to develop statistical models for the channel, which can then be used to design efficient and safe communication networks. WBANs are expected to be used in the healthcare field to enable concepts such as telemedicine. The human body has a complex shape and consists of different tissues. It is then expected that the propagation of the electromagnetic waves near a patient's body will have unique characteristics. In a hospital environment, there are also a variety of electronic devices and specialised medical equipment, which have impact on the electromagnetic propagation. To properly design WBANs is then necessary to have a good understanding of the characteristics of the radio channel in the proximity of the human body within a hospital.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"270 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122948017","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Off-body UWB channel characterisation within a hospital ward environment","authors":"P. Catherwood, W. Scanlon","doi":"10.1504/IJUWBCS.2010.034307","DOIUrl":"https://doi.org/10.1504/IJUWBCS.2010.034307","url":null,"abstract":"Received signal strength measurements and delay statistics are presented for both a stationary and mobile user equipped with a wearable UWB radio transmitter (TX) within a hospital environment. The measurements were made for both waist and chest mounted antennas using RF-over-fibre technology to eliminate any spurious electromagnetic scattering effects associated with metallic coaxial cables. The results show that received signal strength values were dependent on whether transmit and receive antennas had line of sight (LOS) and were also affected by body-shadowing and antenna-body position. For mobile conditions, received signal strength tended to be log normally distributed with non-LOS (NLOS) links having significantly lower mean values. Excess time delay results for mobile user tests were best described by the Weibull distribution. Overall, the results favoured the chest mounted antenna position, with higher mean signal levels, reduced mean excess delay and less difference between LOS and NLOS channels.","PeriodicalId":294875,"journal":{"name":"Int. J. Ultra Wideband Commun. Syst.","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132478918","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}