Switching and protection of multiple transformer arrangement in industrial distribution system 工业配电系统中多变压器布置的开关与保护
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547344
R. Rifaat
{"title":"Switching and protection of multiple transformer arrangement in industrial distribution system","authors":"R. Rifaat","doi":"10.1109/ICPS.2013.6547344","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547344","url":null,"abstract":"In modern industrial electrical distributions, medium size transformers require protection systems that are faster, more reliable and selective than the systems used for their earlier counterparts. To achieve such improved performance, protection engineers will be required to further investigate the magnetic circuit and inrush current of the subject transformers. This paper provides examples of where inrush currents investigations are required for industrial system transformers, aspects of transformer and system configurations that could impact inrush currents, configuration modeling in Electromagnetic Transient Programs and the application of the analysis results in selecting transformer protection schemes that will address system's needs. This paper shows the importance of establishing the protection configuration speed requirements, the criticality of investigating the inrush currents of transformers, a method to analyze the inrush currents and the use of such analysis in selecting protection configuration and settings.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127224741","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Economics of DC power distribution for motors 电机直流配电经济学
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547352
E. Hesla, B. Giese, T. E. Johnson, Massimo Mitolo
{"title":"Economics of DC power distribution for motors","authors":"E. Hesla, B. Giese, T. E. Johnson, Massimo Mitolo","doi":"10.1109/ICPS.2013.6547352","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547352","url":null,"abstract":"DC power distribution presents an opportunity for significant capital savings, energy savings, and potentially for space savings. This paper offers an evaluation of dc power distribution system economics for a process installation with a high percentage of adjustable speed drives.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130623119","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Design of passive harmonic filters to enhance power quality and energy efficiency in ship power systems 无源谐波滤波器的设计以提高船舶电力系统的电能质量和能源效率
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547328
C. Su, Ci-Jhang Hong
{"title":"Design of passive harmonic filters to enhance power quality and energy efficiency in ship power systems","authors":"C. Su, Ci-Jhang Hong","doi":"10.1109/ICPS.2013.6547328","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547328","url":null,"abstract":"Variable frequency drives (VFDs) driven motors for pumps, blowers and fans, and heating, ventilation and air conditioning (HVAC) equipment on ships are rapidly growing in number. Due to their nonlinear nature, they become the major sources of harmonics in electrical power systems on board. To mitigate the harmonics, passive harmonic filters that are an LC circuit tuned to each harmonic order to be filtered have been used. In compliance with the new rule in the emission regulation of the maritime industry, the installation of passive filters has attracting more attention in managing service power energy efficiency. This paper proposed a design of passive filters to reduce the voltage and current distortions in ship power systems while increasing energy efficiency with power factor corrected by passive filters. The inductance and capacitance in the filter are designed according to harmonic currents and reactive power required. The on-board power system of a practical ship with a great number of VFDs is analyzed to illustrate the filter design. The field testing results verified the performance of system with the filter designed by the proposed method.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115806700","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
Rightsizing electrical power systems in large commercial facilities 对大型商业设施的电力系统进行调整
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547348
M. Anthony, T. L. Harman, J. Harvey
{"title":"Rightsizing electrical power systems in large commercial facilities","authors":"M. Anthony, T. L. Harman, J. Harvey","doi":"10.1109/ICPS.2013.6547348","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547348","url":null,"abstract":"For decades, application of National Electrical Code (NEC) rules for sizing services, feeders and branch circuits has resulted in unused capacity in almost all occupancy classes. US Department of Energy data compiled in 1999 indicates average load on building transformers between 10 and 25 percent. More recent data gathered by the educational facilities industry has verified this claim. Recognizing that aggressive energy codes are driving energy consumption lower, and that larger than necessary transformers create larger than necessary flash hazard, the 2014 NEC will provide an exception in Section 220.12 that will permit designers to reduce transformer kVA ratings and all related components of the power delivery system. This is a conservative, incremental step in the direction of reduced load density that is limited to lighting systems. More study of feeder and branch circuit loading is necessary to inform discussion about circuit design methods in future revisions of the NEC.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134538890","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Short-circuit current ratings of equipment 设备的短路额定电流
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547347
D. Neeser
{"title":"Short-circuit current ratings of equipment","authors":"D. Neeser","doi":"10.1109/ICPS.2013.6547347","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547347","url":null,"abstract":"The interrupting rating and short-circuit current rating of equipment is an key consideration for the installation of equipment in electrical distribution systems. To emphasize this consideration, the 2005 National Electrical Code (NEC®) added short-circuit current rating marking requirements for various types of equipment, that previously was not required to be marked with the equipment short-circuit current rating. The marked short-circuit current rating of equipment is determined by the product standards as part of the listing and labeling process of the equipment or an approved method, such as UL 508A for industrial control panels. UL 508A Supplement SB is an analytical (non-tested) method of determining the short-circuit current rating of industrial control panels. This method basically determines the “weak-link” of all power circuit components in the industrial control panel and the lowest rated component then determines the assembly rating. Additional changes to the 2011 NEC have occurred to ensure equipment has short-circuit current ratings sufficient for the fault current where the equipment is installed.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121762571","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Stator thermal time constant 定子热时间常数
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547350
J. Steinmetz, S. Patel, S. Zocholl
{"title":"Stator thermal time constant","authors":"J. Steinmetz, S. Patel, S. Zocholl","doi":"10.1109/ICPS.2013.6547350","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547350","url":null,"abstract":"The thermal model providing motor overload protection is derived from the first order differential equation for heat rise due to current in a conductor. Only the stator thermal time constant and the service factor are the required settings. The thermal model utilizes the full thermal capacity of the motor and allows current swings and cyclic overloads that would trip conventional overcurrent protection but do not actually overheat the motor. Four examples of thermal limit curves and their equations are used to discuss the varying plotting practices in use. The paper also includes a method to calculate the stator thermal time constant using two points read from the overload curve when not available from motor data.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127559894","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Ground-fault loop impedance calculations in single-phase systems 单相系统接地故障环阻抗计算
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547335
Haijun Liu, Massimo Mitolo, J. Qiu
{"title":"Ground-fault loop impedance calculations in single-phase systems","authors":"Haijun Liu, Massimo Mitolo, J. Qiu","doi":"10.1109/ICPS.2013.6547335","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547335","url":null,"abstract":"Protection against electric shock in low-voltage installations by automatic disconnection of the supply must be provided in compliance with applicable national or international standards. Such regulations (e.g. National Electrical Code in the U.S., IEC 60364, BS 7671 in the U.K., etc.) take into account the earthing system of the installation, such as TT, TN-C-S, or IT systems. To realize the protection against indirect contact, the disconnection of the supply must occur within a permissible safe time. To this purpose, the determination of the actual ground fault-loop impedance (which may, or may not, comprise the earth) is essential. This impedance, in fact, must not exceed a maximum value, so that a sufficient ground-fault current can circulate and operate protective devices within the safe time. In some instances, explained in this paper, safety might be achieved, or increased, by converting one earthing system into another (e.g. from TT to TN, from TN to TT, from TN-C to TN-S, etc.), by means of single-phase transformers. This conversion can be promoted by either utilities or users. Other cases of conversion of grounding type, although not driven by safety concerns, are also examined, as they can be used to study the influence of neutral earthing on single-phase short-circuits. This paper seeks to clarify the circuits to be employed for the calculation of ground fault-loop impedances when the earthing type changes across single-phase transformers. The quantitative analysis of this topic is not present in current technical standards.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"166 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122926715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Upgrading relay protection? — Be prepared 升级继电保护?-做好准备
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547351
D. Ransom
{"title":"Upgrading relay protection? — Be prepared","authors":"D. Ransom","doi":"10.1109/ICPS.2013.6547351","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547351","url":null,"abstract":"There are many advantages to upgrading old electromechanical, solid-state, and first-generation numeric relays with modern numeric relays. Reliability increases because there is less direct wiring and interconnection wiring. Reliability and security of multifunction logic and settings are improved with next-generation user interface software. Remote I/O modules, remote analog/digital inputs, and thermal measurement capabilities have expanded the protection, control, and monitoring. New protection and monitoring features improve power system equipment life and increase personnel safety. Maintenance costs are reduced, while internal watchdogs alert the user if the relay has a problem. Settings groups can be changed instantaneously to adapt to varying power system requirements. Modern, second-generation numeric relays offer a variety of secure communications capabilities for interfacing with Smart Grid controls, SCADA systems, and business networks. Event memory is larger for more on-board, standardized oscillographs and event reporting. Relay security is in accord with the latest NERC standards. Initially, every relay upgrade seems simple and straight forward; then come the details. Operating personnel have expectations for reading targets, resetting trips, ease of interface for settings and events, motor restarting, synch closing, etc. Regulator requirements (NERC-CIP, for example) must be implemented while maintaining smooth operations. Relay engineers must assure that operational ease is maintained with the new upgrade relay. Accurate one-line drawings and connection drawings, as well as good wiring documentation, are essential. Escutcheon plates might be necessary, or perhaps switchgear will need modification (panel cutting, new doors, relocation, etc). Also, this is an opportunity to reevaluate arc-flash hazards and possibly reduce the risks. These and other considerations are taken from actual relay replacement projects. This paper provides guidance for your next replacement or upgrade project, resulting in reducing cost, saving time, and minimizing unexpected or unplanned complications.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129176659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Seismic qualification of electrical equipment in critical facilities 关键设施电气设备抗震鉴定
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547338
G. Parise, L. Martirano, L. Parise, M. De Angelis, A. Reggio, J. Weber
{"title":"Seismic qualification of electrical equipment in critical facilities","authors":"G. Parise, L. Martirano, L. Parise, M. De Angelis, A. Reggio, J. Weber","doi":"10.1109/ICPS.2013.6547338","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547338","url":null,"abstract":"Electrical equipment, particularly in critical facilities, should be subjected to seismic qualification. With this aim, seismic standards and codes should define essential requirements and harmonized prescriptive protocols. The main objectives of the present paper are to define the steering criteria for the seismic qualification of electrical equipment and to illustrate how to implement qualified equipment items in civil and industrial facilities. Special attention is given to critical facilities, whose operational continuity primarily depends on the integrity and functionality of the engineering systems and their equipment. A new approach to the seismic qualification is introduced, which highlights the need for different degrees of safety of the electrical equipment depending on the intensity of the expected ground motion, on the characteristics of the equipment item, on its location within the supporting structure and on life-safety considerations. The seismic demand to the equipment is defined in terms of Equipment Seismic Levels (ESL), while its inherent seismic capacity is classified in terms of Equipment Qualification Categories (EQC) and equipment weight. It is eventually recognized that certify and mark all the produced equipment items according to their qualified seismic capacity would allow a straightforward and reliable way to implement them in civil and industrial facilities.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115488108","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
AC DC power circuits design by microsystem criteria 用微系统准则设计交直流电源电路
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference Pub Date : 2013-06-27 DOI: 10.1109/ICPS.2013.6547339
G. Parise, E. Hesla, L. Parise
{"title":"AC DC power circuits design by microsystem criteria","authors":"G. Parise, E. Hesla, L. Parise","doi":"10.1109/ICPS.2013.6547339","DOIUrl":"https://doi.org/10.1109/ICPS.2013.6547339","url":null,"abstract":"Innovation in the residential and commercial LV distribution for the near future it is necessary to effectively implement the objectives of improvements of energy savings and renewable energy and further developments, such as DC distributions. Microsystem criteria in designing AC and DC power circuits consist in modeling their structure with components of smaller size, in grouping adequately the supplying loads, in adopting circuit with conductors in bunch, in loop or in rope designs. “Natural” parameters like steady and transient current density and load current moment density are introduced to support the configuration of circuits and the sizing of conductor cross-section area especially for DC circuits adopting nominal voltages lower than AC circuits.","PeriodicalId":290503,"journal":{"name":"49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127137611","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书