1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference最新文献

筛选
英文 中文
Design And Development Of A Collimator And Robot For Use In Detector/collimator Studies 用于探测器/准直器研究的准直器和机器人的设计与开发
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701823
S. Kohlmyer, T. Lewellen, D. Mankoff, M. S. Kaplan
{"title":"Design And Development Of A Collimator And Robot For Use In Detector/collimator Studies","authors":"S. Kohlmyer, T. Lewellen, D. Mankoff, M. S. Kaplan","doi":"10.1109/NSSMIC.1993.701823","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701823","url":null,"abstract":"As part of a project aimed at understanding and accounting for collimator effects in SPECT (single photon emission computed tomography) and PET (positron emission tomography) images, a robot and collimator system is being constructed to accurately position a narrow beam of radiation. The beam from the collimator will have a diameter of no more than 5 mm FWTM (full width tenth maximum) at a distance of 30 cm and will improve, due to penumbra effects, as the distance decreases. Positioning will be done by a wrist (two degrees of angular motion) on a Cartesian arm (three degrees of linear motion) controlled by a CAMAC (Computer Automated Measurement and Control) system and LabView software on the Macintosh. Beam positioning error should be less than 2.5 mm at a distance of 30 cm. While the majority of the use will be in a bench environment, the design will also function within the tunnel of a whole body PET scanner or with a SPECT camera. With this in mind, the stepping motor drivers will toggle a signal, compatible with standard cardiac gating signals, to signify if the arm is stationary or in motion. This will allow sorting of many positions taken during the same acquisition on most PET and SPECT scanners. As a further convenience, the collimator assembly will have an internal laser that will aid in calibration of the robot and accurate positioning of the beam.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125276593","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
The DuAmp - An Alternative Input Configuration For Detector Preamplifiers DuAmp -检测器前置放大器的另一种输入配置
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701719
V. Jordanov, G. Knoll, H. Spieler, A. Huber, J.A. Pantazis
{"title":"The DuAmp - An Alternative Input Configuration For Detector Preamplifiers","authors":"V. Jordanov, G. Knoll, H. Spieler, A. Huber, J.A. Pantazis","doi":"10.1109/NSSMIC.1993.701719","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701719","url":null,"abstract":"An alternative type of detector-preamplifier configuration (DuAmp) has been assembled and tested* . The circuit employs two identical charge sensitive preamplifiers with the detector connected between the two preamplifier inputs. One of the preamplifiers is powered by voltage supplies referenced to ground potential, while the second one is powered by isolated supplies referenced to the bias voltage of the detector. The detector is biased by the voltage difference between the inputs of the two preamplifiers. The output of one of the preamplifiers is inverted and added to the output signal of the other preamplifier. The resultant signal is processed by pulse shaping electronics. For our application, the circuit has been shown to exhibit an overall noise level that is lower than that obtained using an equivalent single preamplifier in a conventional manner. A preliminary analysis of the circuit shows that the improvements are to be expected only in circumstances in which the ratio of detector to preamplifier capacitance is small.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125400094","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Noise characteristics of a SPECT simulation system SPECT仿真系统的噪声特性
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.373548
M. Bélanger, A. B. Dobrzeniecki, J. Yanch
{"title":"Noise characteristics of a SPECT simulation system","authors":"M. Bélanger, A. B. Dobrzeniecki, J. Yanch","doi":"10.1109/NSSMIC.1993.373548","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.373548","url":null,"abstract":"The noise characteristics of synthetic images generated by a Monte Carlo SPECT simulation package (Sim-SPECT) were examined. Sim-SPECT generates single planer projections via analog Monte Carlo methods but uses a directional photon cloning technique to simulate tomographic acquisition. Statistical noise characteristics were investigated in both single planar projection and tomographic acquisitions, the latter to assess the potential noise distortion of the directional cloning algorithm. The root-mean-square (EMS) and the noise power spectrum were two mathematical measures used to characterise the noise. NPS was estimated using spectral averaging techniques. Synthetic Sim-SPECT and experimental data (both single planar and tomographic acquisitions) were obtained using phantoms of identical dimensions and uniform activity.<<ETX>>","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"151 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116526415","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A Judgment System Being Able To Construct By Personal Computer 一种能用个人计算机构建的判断系统
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701784
Y. Narita, Yeng Chen, H. Tamamoto, R. Igarashi
{"title":"A Judgment System Being Able To Construct By Personal Computer","authors":"Y. Narita, Yeng Chen, H. Tamamoto, R. Igarashi","doi":"10.1109/NSSMIC.1993.701784","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701784","url":null,"abstract":"Since the judgment system which is adopted in a nuclear facility is well designed, users cannot easily get the explanation of rules and cannot modify registered rules. This paper refers to the development of judgment system with which people can construct judgment rules easily using a personal computer. We can apply the system to actual judgment process. With the present system by applying 3AND-3-OR judgment rule to within 60 items, we can obtain the result of 4-Stage-20-Item judgment. Because of its simplicity, the system proposed may be used by people who do not specialize in a computer. Our system can be operated under various DOS computers at a nearly real-time speed.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122412261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Operative Petrophysical Interpretation Of The Nuclear Well Logging Data 核测井资料的有效岩石物理解释
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701686
D. Kozhevnikov, N. Lazutkina
{"title":"Operative Petrophysical Interpretation Of The Nuclear Well Logging Data","authors":"D. Kozhevnikov, N. Lazutkina","doi":"10.1109/NSSMIC.1993.701686","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701686","url":null,"abstract":"A new approach to algorithmical support for operative petrophysical interpretation of nuclear well logging (CNL or SNP, NGRS or NGR, FDL) data is described. Original modules of individual interpretation takes into account radial heterogeneity of a tool-borehole-bed system by radial sensitivity and integral radial geometric factors for different zones. For complex interpretation componential analysis method with adaptive petrophisycal tuning and preliminary clastering of the geological section are used. Reliable extracting of reservoirs is obtained by determining of mineralogical composition of deposits and by petrophysical filtration according to evaluated dynamic porosity. Some results of the componential analysis for terrigeneous deposits of Tyumen Suite (West Siberia) are presented.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122547032","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Parametric X-rays As A Promising Radiation Mechanism For High Energy Particle Identification 参数x射线作为一种有前途的高能粒子识别辐射机制
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701657
V. Afanasenko, V. Baryshevsky, A. Lobko
{"title":"Parametric X-rays As A Promising Radiation Mechanism For High Energy Particle Identification","authors":"V. Afanasenko, V. Baryshevsky, A. Lobko","doi":"10.1109/NSSMIC.1993.701657","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701657","url":null,"abstract":"The development of new large accelerators arises a problem of the measurements of super-high energy beam parameters. One of the comparatively new physical effects, which can be used for solution of this problem is parametric X-rays (PX) generated by an ultra-relativistic particle passing in a single crystal with uniform velocity. Dependence of the PX intensity and angular distribution on the charged particle Lorenz factor is shown. The possibilities of the PX application for energy determination and identrfcation of the high energy particles and ions have been discussed.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124783668","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fast Bayesian techniques for attenuation corrected whole-body PET 衰减校正全身PET的快速贝叶斯技术
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.373625
E. Mumcuoglu, R. Leahy, S. Cherry
{"title":"Fast Bayesian techniques for attenuation corrected whole-body PET","authors":"E. Mumcuoglu, R. Leahy, S. Cherry","doi":"10.1109/NSSMIC.1993.373625","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.373625","url":null,"abstract":"The authors describe conjugate gradient algorithms for reconstruction of transmission and emission PET images. The reconstructions are based on a Bayesian formulation where the data are modeled as a collection of independent Poisson random variables and the image is modeled using a Markov random field. To ensure non-negativity of the solution a penalty function is used to convert the problem to one of unconstrained optimization. Preconditioners are used to enhance convergence rates. These methods generally achieve effective convergence in 15-25 iterations. Reconstructions are presented of an /sup 18/FDG whole body scan from data collected using a Siemens/CTI ECAT931 whole body system. These results indicate significant improvements in emission image quality using the Bayesian approach, in comparison to filtered backprojection, particularly when reprojections of the MAP transmission image are used in place of the standard attenuation correction factors.<<ETX>>","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126918451","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Gamma-rays Spectrometric System For Remote Detection And Control Of Fissile Materials 用于裂变材料远程探测和控制的伽马射线光谱测量系统
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701685
V. Baryshevsky, A.A. Khrutchinsky, V. Moroz, M.D. Dezhurko
{"title":"Gamma-rays Spectrometric System For Remote Detection And Control Of Fissile Materials","authors":"V. Baryshevsky, A.A. Khrutchinsky, V. Moroz, M.D. Dezhurko","doi":"10.1109/NSSMIC.1993.701685","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701685","url":null,"abstract":"","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"126 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123371801","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison Of Bayesian Methods For Sinogram Filtered Backprojection And Algebraic Reconstruction 正弦图滤波反投影与代数重建贝叶斯方法的比较
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701820
G. Chinn, Sung-Cheng Huang, S. Siegel, B. Kwan
{"title":"Comparison Of Bayesian Methods For Sinogram Filtered Backprojection And Algebraic Reconstruction","authors":"G. Chinn, Sung-Cheng Huang, S. Siegel, B. Kwan","doi":"10.1109/NSSMIC.1993.701820","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701820","url":null,"abstract":"Image reconstruction by Maximum a Posteriori sinogram restoration and Radon inversion (MAP-RI) was evaluated. Its equivalence with Maximum a Posteriori al- gebraic reconstruction (MAP-ART) was established. A fast practical implementation of MAP-RI was developed using truncated priors and filtered backprojection (MAP-FBP). Simulations using one plane of the Hoffman 3-D brain phan- tom at both low SNR and high SNR were used for quanti- tative comparisons of resolution and noise variance. Com- pared to conventional FBP with ramp cutoff at Nyquist, MAP-ART can produce images with 40% greater resolu- tion and comparable noise variance in the high activity re- gions of phantoms. In comparison, MAP-FBP can yield a 30% improvement in resolution with equivalent noise to FBP. However, MAP-FBP using an iterative expectation- maximization (EM) algorithm converges rapidly (< 10 iter- ations) with an order-of-magnitude lower cost per iteration compared to MAP-ART.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121543242","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A CCD Based X-ray Imaging System For Industrial Applications 基于CCD的工业x射线成像系统
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference Pub Date : 1993-10-31 DOI: 10.1109/NSSMIC.1993.701678
H. Chou, D. Lai, C.I. Hsu
{"title":"A CCD Based X-ray Imaging System For Industrial Applications","authors":"H. Chou, D. Lai, C.I. Hsu","doi":"10.1109/NSSMIC.1993.701678","DOIUrl":"https://doi.org/10.1109/NSSMIC.1993.701678","url":null,"abstract":"The presented x-ray imaging system is based on a typical industrial grade charge-coupled device (CCD) which is coupled to a phosphor screen and operated at room-temperature. Image acquisition and data analysis is performed using a commercial 8-bit frame grabber and a personal computer. The setup, noise reduction, and the response of fluorescent converters were evaluated with an x-ray tube. Measurements indicate that the system can achieve a spatial resolution of 16 line pairs per mm and a contrast of sensing a piece of 0.1 mm thick plastic sheet. Demonstrations have shown that the system can detect the fluid level in opaque plastic bottles, flaws in mechanical parts, wiring diagram in electrical parts, and to the extreme, 30 pm gold wires in plastic capped integrated circuit chips.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124385846","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信