Russian Technological Journal最新文献

筛选
英文 中文
The use of complex structure splines in roadway design 在道路设计中使用复杂结构样条
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-111-122
V. I. Struchenkov, D. A. Karpov
{"title":"The use of complex structure splines in roadway design","authors":"V. I. Struchenkov, D. A. Karpov","doi":"10.32362/2500-316x-2024-12-1-111-122","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-111-122","url":null,"abstract":"Objectives. The aim of the work is to develop the theory of spline-approximation of a sequence of points on a plane for using compound splines with a complex structure. In contrast to a simple spline (e.g., polynomial), a compound spline contains repeating bundles of several elements. Such problems typically arise in the design of traces for railroads and highways. The plan (projection on the horizontal plane) of such a trace is a curve consisting of a repeating bundle of elements “line + clothoid + circle + clothoid ...,” which ensures continuity not only of curve and tangent but also of curvature. The number of spline elements, which is unknown, should be determined in the process of solving the design problem. An algorithm for solving the problem with respect to the spline, which consists of arcs conjugated by straight lines, was implemented and published in an earlier work. The approximating spline in the general case is a multivalued function, whose ordinates may be limited. Another significant factor that complicates the problem is the presence of clothoids that are not expressed analytically (in a formula). The algorithm for determining the number of elements of a spline with clothoids and constructing an initial approximation was also published earlier. The present work considers the next stage of solving the spline approximation problem: optimization using a nonlinear programming spline obtained at the first stage by means of the dynamic programming method.Methods. A new mathematical model in the form of a modified Lagrange function is used together with a special nonlinear programming algorithm to optimize spline parameters. In this case, it is possible to calculate the derivatives of the objective function by the spline parameters in the absence of its analytical expression through these parameters.Results. A mathematical model and algorithm for optimization of compound spline parameters comprising arcs of circles conjugated by clothoids and lines have been developed.Conclusions. The previously proposed two-step scheme for designing paths of linear structures is also suitable for the utilization of compound splines with clothoids.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"35 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139810260","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Implementation of bagging in time series forecasting 在时间序列预测中实施套袋法
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-101-110
I. V. Gramovich, D. Musatov, D. Petrusevich
{"title":"Implementation of bagging in time series forecasting","authors":"I. V. Gramovich, D. Musatov, D. Petrusevich","doi":"10.32362/2500-316x-2024-12-1-101-110","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-101-110","url":null,"abstract":"Objectives. The purpose of the article is to build different models of bagging, to compare the accuracy of their forecasts for the test period against standard models, and to draw conclusions about the possibility of further use of the bagging technique in time series modeling.Methods. This study examines the application of bagging to the random component of a time series formed after removing the trend and seasonal part. A bootstrapped series combining into a new random component is constructed. Based on the component thus obtained, a new model of the series is built. According to many authors, this approach allows the accuracy of the time series model to be improved by better estimating the distribution.Results. The theoretical part summarizes the characteristics of the different bagging models. The difference between them comes down to the bias estimate obtained, since the measurements making up the bootstraps are not random. We present a computational experiment in which time series models are constructed using the index of monetary income of the population, the macroeconomic statistics of the Russian Federation, and the stock price of Sberbank. Forecasts for the test period obtained by standard, neural network and bagging-based models for some time series are compared in the computational experiment. In the simplest implementation, bagging showed results comparable to ARIMA and ETS standard models, while and slightly inferior to neural network models for seasonal series. In the case of non-seasonal series, the ARIMA and ETS standard models gave the best results, while bagging models gave close results. Both groups of models significantly surpassed the result of neural network models.Conclusions. When using bagging, the best results are obtained when modeling seasonal time series. The quality of forecasts of seigniorage models is somewhat inferior to the quality of forecasts of neural network models, but is at the same level as that of standard ARIMA and ETS models. Bagging-based models should be used for time series modeling. Different functions over the values of the series when constructing bootstraps should be studied in future work.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"5 2","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139870356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Implementation of bagging in time series forecasting 在时间序列预测中实施套袋法
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-101-110
I. V. Gramovich, D. Musatov, D. Petrusevich
{"title":"Implementation of bagging in time series forecasting","authors":"I. V. Gramovich, D. Musatov, D. Petrusevich","doi":"10.32362/2500-316x-2024-12-1-101-110","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-101-110","url":null,"abstract":"Objectives. The purpose of the article is to build different models of bagging, to compare the accuracy of their forecasts for the test period against standard models, and to draw conclusions about the possibility of further use of the bagging technique in time series modeling.Methods. This study examines the application of bagging to the random component of a time series formed after removing the trend and seasonal part. A bootstrapped series combining into a new random component is constructed. Based on the component thus obtained, a new model of the series is built. According to many authors, this approach allows the accuracy of the time series model to be improved by better estimating the distribution.Results. The theoretical part summarizes the characteristics of the different bagging models. The difference between them comes down to the bias estimate obtained, since the measurements making up the bootstraps are not random. We present a computational experiment in which time series models are constructed using the index of monetary income of the population, the macroeconomic statistics of the Russian Federation, and the stock price of Sberbank. Forecasts for the test period obtained by standard, neural network and bagging-based models for some time series are compared in the computational experiment. In the simplest implementation, bagging showed results comparable to ARIMA and ETS standard models, while and slightly inferior to neural network models for seasonal series. In the case of non-seasonal series, the ARIMA and ETS standard models gave the best results, while bagging models gave close results. Both groups of models significantly surpassed the result of neural network models.Conclusions. When using bagging, the best results are obtained when modeling seasonal time series. The quality of forecasts of seigniorage models is somewhat inferior to the quality of forecasts of neural network models, but is at the same level as that of standard ARIMA and ETS models. Bagging-based models should be used for time series modeling. Different functions over the values of the series when constructing bootstraps should be studied in future work.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"38 6","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139810308","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mathematical model of a DC/DC converter based on SEPIC topology 基于 SEPIC 拓扑的 DC/DC 转换器数学模型
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-69-79
A. I. Lavrenov, V. K. Bityukov
{"title":"Mathematical model of a DC/DC converter based on SEPIC topology","authors":"A. I. Lavrenov, V. K. Bityukov","doi":"10.32362/2500-316x-2024-12-1-69-79","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-69-79","url":null,"abstract":"Objectives. A DC/DC converter based on SEPIC topology is a unipolar electronic device which converts an input positive voltage into a stabilized output voltage of the same polarity. It also has the ability to regulate polarity both below and above the input voltage. The aim of the paper is to analyze the DC/DC converter in its both operation phases, as well as to draw up equivalent circuits and obtain characterizing differential equations using Kirchhoff’s rules for each phase. Each system of differential equations is reduced to Cauchy equations, in order to be further transformed into a limiting continuous mathematical model. Each system of equations is converted into a matrix form and subsequently combined into a single matrix system.Methods. The construction of a limiting continuous mathematical model was accomplished using Kirchhoff’s rules. Multisim software was used for the computer simulation, thus enabling the calculated results of direct currents and voltages to be compared to those of the simulation.Results. Results show that the phase coordinates of the mathematical model tend towards the values of real currents and voltages of the converter at a switching frequency higher than 200 kHz. Fairly good agreement is established between the calculated values of currents and voltages and the values obtained by simulation (with varying fill factor and switching frequency).Conclusions. The resulting limiting continuous mathematical model of the DC/DC converter based on SEPIC topology allows for an estimation of the dependence of the currents flowing through the inductor windings and the voltages across the capacitors on a number of parameters. The limiting continuous mathematical model of the DC/DC converter based on SEPIC topology is the basis for its circuit design and physical-and-mathematical analysis.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"59 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139869860","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The use of complex structure splines in roadway design 在道路设计中使用复杂结构样条
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-111-122
V. I. Struchenkov, D. A. Karpov
{"title":"The use of complex structure splines in roadway design","authors":"V. I. Struchenkov, D. A. Karpov","doi":"10.32362/2500-316x-2024-12-1-111-122","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-111-122","url":null,"abstract":"Objectives. The aim of the work is to develop the theory of spline-approximation of a sequence of points on a plane for using compound splines with a complex structure. In contrast to a simple spline (e.g., polynomial), a compound spline contains repeating bundles of several elements. Such problems typically arise in the design of traces for railroads and highways. The plan (projection on the horizontal plane) of such a trace is a curve consisting of a repeating bundle of elements “line + clothoid + circle + clothoid ...,” which ensures continuity not only of curve and tangent but also of curvature. The number of spline elements, which is unknown, should be determined in the process of solving the design problem. An algorithm for solving the problem with respect to the spline, which consists of arcs conjugated by straight lines, was implemented and published in an earlier work. The approximating spline in the general case is a multivalued function, whose ordinates may be limited. Another significant factor that complicates the problem is the presence of clothoids that are not expressed analytically (in a formula). The algorithm for determining the number of elements of a spline with clothoids and constructing an initial approximation was also published earlier. The present work considers the next stage of solving the spline approximation problem: optimization using a nonlinear programming spline obtained at the first stage by means of the dynamic programming method.Methods. A new mathematical model in the form of a modified Lagrange function is used together with a special nonlinear programming algorithm to optimize spline parameters. In this case, it is possible to calculate the derivatives of the objective function by the spline parameters in the absence of its analytical expression through these parameters.Results. A mathematical model and algorithm for optimization of compound spline parameters comprising arcs of circles conjugated by clothoids and lines have been developed.Conclusions. The previously proposed two-step scheme for designing paths of linear structures is also suitable for the utilization of compound splines with clothoids.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"18 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139870363","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quality control of instruments for measuring the characteristics of bactericidal UV radiation 紫外线杀菌辐射特性测量仪器的质量控制
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-123-132
O. A. Minaeva, A. V. Ragutkin, S. Anevsky, R. Minaev, Th. T. Minh, I. A. Romanova
{"title":"Quality control of instruments for measuring the characteristics of bactericidal UV radiation","authors":"O. A. Minaeva, A. V. Ragutkin, S. Anevsky, R. Minaev, Th. T. Minh, I. A. Romanova","doi":"10.32362/2500-316x-2024-12-1-123-132","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-123-132","url":null,"abstract":"Objectives. Quality control of instruments for measuring bactericidal irradiance of ultraviolet (UV) radiation is based on studying the main metrological characteristics. These characteristics include: angular and spectral sensitivity; linearity range; and absolute calibration in irradiance units. Deviations of the angular sensitivity of measuring instruments from the ideal cosine characteristic can significantly impact error estimation. They can also lead to the distortion of measurement results and a significant difference in instrument readings. The aim of this work is to enhance accuracy in resolving metrological problems of determining irradiance of bactericidal radiation.Methods. An effective method of resolving this problem is to introduce correction coefficients for the angular sensitivity of radiometers, spectroradiometers and dosimeters. The values are calculated based on the results of measurements on the goniometer when testing measuring instruments. An important role is played by computer models and digital twins of measuring instruments based on the results of studies of the metrological characteristics of radiometers by means of software. This includes modeling the measuring task.Results. The study of angular dependence of bactericidal UV radiometer sensitivity complemented by an analysis of measurement results obtained by other authors allows determining the value of the angular sensitivity correction coefficients by the deviation of the angular sensitivity of the irradiance measuring instruments of bactericidal radiation from the standard cosine dependence.Conclusions. Deviations of the angular dependence of bactericidal radiation UV radiometer sensitivity from the cosine characteristic lead to a significant underestimation of the irradiance measurements results from extended emitters. An effective solution is the use of digital angular sensitivity correction coefficients to measure the irradiance of bactericidal radiation determined during tests. When assessing the quality of radiometers, spectroradiometers and dosimeters for bactericidal radiation, incomplete control of the main metrological characteristics of the measuring instruments creates risks of serious errors in the measurement results of bactericidal irradiance.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"109 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139870781","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Local spatial analysis of EEG signals using the Laplacian montage 利用拉普拉斯蒙太奇对脑电图信号进行局部空间分析
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-92-100
A. A. Slezkin, S. P. Stepina, N. Gusein-zade
{"title":"Local spatial analysis of EEG signals using the Laplacian montage","authors":"A. A. Slezkin, S. P. Stepina, N. Gusein-zade","doi":"10.32362/2500-316x-2024-12-1-92-100","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-92-100","url":null,"abstract":"Objectives. One pressing problem when recording brain activity signals by electroencephalography (EEG) is the need to reduce the effect of interference (artifacts). This study presents a method for resolving this problem using the Laplace differential operator. The aim is to determine the number of electrodes included in the Laplacian montage, as well as to clarify the requirements for the geometric shape of their placement, in order to ensure the best quality of EEG signal processing.Methods. The Laplacian montage method is based on the use of individual electrodes to determine the second derivative of the signal, proportional to the electric current at the corresponding point on the surface of the head. This approach allows the potential of neural activity of the source located in a small area limited by the electrode complex to be evaluated. By using a small number of equidistant electrodes placed around the target electrode, the Laplacian montage can produce a significantly higher quality signal from the area under the electrode complex.Results. Among all the methods for constructing the Laplacian montage discussed in the article, a complex consisting of 16 + 1 electrodes was shown to be preferable. The choice of the 16 + 1 scheme was determined by the best compromise between the quality of EEG signal processing and the complexity of manufacturing the electrode complex with given geometric parameters. The quality assessment was carried out by simulating the interference signal which allowed the correctness of the choice of installation design to be evaluated.Conclusions. The use of the Laplacian montage method can significantly reduce the effect of artifacts. The proposed montage scheme ensures a good suppression of interference signals, the sources of which are located far beyond the projection of the electrode complex. However, not all interference arising from sources deep inside the brain, can be effectively suppressed using the Laplacian montage scheme alone.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"88 14","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139810648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mathematical model of a DC/DC converter based on SEPIC topology 基于 SEPIC 拓扑的 DC/DC 转换器数学模型
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-69-79
A. I. Lavrenov, V. K. Bityukov
{"title":"Mathematical model of a DC/DC converter based on SEPIC topology","authors":"A. I. Lavrenov, V. K. Bityukov","doi":"10.32362/2500-316x-2024-12-1-69-79","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-69-79","url":null,"abstract":"Objectives. A DC/DC converter based on SEPIC topology is a unipolar electronic device which converts an input positive voltage into a stabilized output voltage of the same polarity. It also has the ability to regulate polarity both below and above the input voltage. The aim of the paper is to analyze the DC/DC converter in its both operation phases, as well as to draw up equivalent circuits and obtain characterizing differential equations using Kirchhoff’s rules for each phase. Each system of differential equations is reduced to Cauchy equations, in order to be further transformed into a limiting continuous mathematical model. Each system of equations is converted into a matrix form and subsequently combined into a single matrix system.Methods. The construction of a limiting continuous mathematical model was accomplished using Kirchhoff’s rules. Multisim software was used for the computer simulation, thus enabling the calculated results of direct currents and voltages to be compared to those of the simulation.Results. Results show that the phase coordinates of the mathematical model tend towards the values of real currents and voltages of the converter at a switching frequency higher than 200 kHz. Fairly good agreement is established between the calculated values of currents and voltages and the values obtained by simulation (with varying fill factor and switching frequency).Conclusions. The resulting limiting continuous mathematical model of the DC/DC converter based on SEPIC topology allows for an estimation of the dependence of the currents flowing through the inductor windings and the voltages across the capacitors on a number of parameters. The limiting continuous mathematical model of the DC/DC converter based on SEPIC topology is the basis for its circuit design and physical-and-mathematical analysis.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"31 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139810077","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Local spatial analysis of EEG signals using the Laplacian montage 利用拉普拉斯蒙太奇对脑电图信号进行局部空间分析
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-92-100
A. A. Slezkin, S. P. Stepina, N. Gusein-zade
{"title":"Local spatial analysis of EEG signals using the Laplacian montage","authors":"A. A. Slezkin, S. P. Stepina, N. Gusein-zade","doi":"10.32362/2500-316x-2024-12-1-92-100","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-92-100","url":null,"abstract":"Objectives. One pressing problem when recording brain activity signals by electroencephalography (EEG) is the need to reduce the effect of interference (artifacts). This study presents a method for resolving this problem using the Laplace differential operator. The aim is to determine the number of electrodes included in the Laplacian montage, as well as to clarify the requirements for the geometric shape of their placement, in order to ensure the best quality of EEG signal processing.Methods. The Laplacian montage method is based on the use of individual electrodes to determine the second derivative of the signal, proportional to the electric current at the corresponding point on the surface of the head. This approach allows the potential of neural activity of the source located in a small area limited by the electrode complex to be evaluated. By using a small number of equidistant electrodes placed around the target electrode, the Laplacian montage can produce a significantly higher quality signal from the area under the electrode complex.Results. Among all the methods for constructing the Laplacian montage discussed in the article, a complex consisting of 16 + 1 electrodes was shown to be preferable. The choice of the 16 + 1 scheme was determined by the best compromise between the quality of EEG signal processing and the complexity of manufacturing the electrode complex with given geometric parameters. The quality assessment was carried out by simulating the interference signal which allowed the correctness of the choice of installation design to be evaluated.Conclusions. The use of the Laplacian montage method can significantly reduce the effect of artifacts. The proposed montage scheme ensures a good suppression of interference signals, the sources of which are located far beyond the projection of the electrode complex. However, not all interference arising from sources deep inside the brain, can be effectively suppressed using the Laplacian montage scheme alone.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"91 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139870834","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quality control of instruments for measuring the characteristics of bactericidal UV radiation 紫外线杀菌辐射特性测量仪器的质量控制
Russian Technological Journal Pub Date : 2024-02-02 DOI: 10.32362/2500-316x-2024-12-1-123-132
O. A. Minaeva, A. V. Ragutkin, S. Anevsky, R. Minaev, Th. T. Minh, I. A. Romanova
{"title":"Quality control of instruments for measuring the characteristics of bactericidal UV radiation","authors":"O. A. Minaeva, A. V. Ragutkin, S. Anevsky, R. Minaev, Th. T. Minh, I. A. Romanova","doi":"10.32362/2500-316x-2024-12-1-123-132","DOIUrl":"https://doi.org/10.32362/2500-316x-2024-12-1-123-132","url":null,"abstract":"Objectives. Quality control of instruments for measuring bactericidal irradiance of ultraviolet (UV) radiation is based on studying the main metrological characteristics. These characteristics include: angular and spectral sensitivity; linearity range; and absolute calibration in irradiance units. Deviations of the angular sensitivity of measuring instruments from the ideal cosine characteristic can significantly impact error estimation. They can also lead to the distortion of measurement results and a significant difference in instrument readings. The aim of this work is to enhance accuracy in resolving metrological problems of determining irradiance of bactericidal radiation.Methods. An effective method of resolving this problem is to introduce correction coefficients for the angular sensitivity of radiometers, spectroradiometers and dosimeters. The values are calculated based on the results of measurements on the goniometer when testing measuring instruments. An important role is played by computer models and digital twins of measuring instruments based on the results of studies of the metrological characteristics of radiometers by means of software. This includes modeling the measuring task.Results. The study of angular dependence of bactericidal UV radiometer sensitivity complemented by an analysis of measurement results obtained by other authors allows determining the value of the angular sensitivity correction coefficients by the deviation of the angular sensitivity of the irradiance measuring instruments of bactericidal radiation from the standard cosine dependence.Conclusions. Deviations of the angular dependence of bactericidal radiation UV radiometer sensitivity from the cosine characteristic lead to a significant underestimation of the irradiance measurements results from extended emitters. An effective solution is the use of digital angular sensitivity correction coefficients to measure the irradiance of bactericidal radiation determined during tests. When assessing the quality of radiometers, spectroradiometers and dosimeters for bactericidal radiation, incomplete control of the main metrological characteristics of the measuring instruments creates risks of serious errors in the measurement results of bactericidal irradiance.","PeriodicalId":282368,"journal":{"name":"Russian Technological Journal","volume":"107 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139810749","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信