Journal of Electronics Cooling and Thermal Control最新文献

筛选
英文 中文
Techno-Economic and Sustainability Analysis of Potential Cooling Methods in Irish Data Centres 爱尔兰数据中心潜在冷却方法的技术经济和可持续性分析
Journal of Electronics Cooling and Thermal Control Pub Date : 2021-08-04 DOI: 10.4236/jectc.2021.103003
Lee Gibbons, T. Persoons, S. Alimohammadi
{"title":"Techno-Economic and Sustainability Analysis of Potential Cooling Methods in Irish Data Centres","authors":"Lee Gibbons, T. Persoons, S. Alimohammadi","doi":"10.4236/jectc.2021.103003","DOIUrl":"https://doi.org/10.4236/jectc.2021.103003","url":null,"abstract":"11% of Irish electricity was consumed by data centres in 2020. The Irish data centre industry and the cooling methods utilised require reformative actions in the coming years to meet EU Energy policies. The resell of heat, alternative cooling methods or carbon reduction methods are all possibilities to conform to these policies. This study aims to determine the viability of the resell of waste heat from data centres both technically and economically. This was determined using a novel application of thermodynamics to determine waste heat recovery potential in Irish data centres, and the current methods of heat generation for economical comparison. This paper also explores policy surrounding waste heat recovery within the industry. The Recoverable Carnot Equivalent Power (RCEP) is theoretically calculated for the three potential cooling methods for Irish data centres. These are air, hybrid, and immersion cooling techniques. This is the maximum useable heat that can be recovered from a data centre rack. This study is established under current operating conditions which are optimised for cooling performance, that air cooling has the highest potential RCEP of 0.39 kW/rack. This is approximately 8% of the input electrical power that can be captured as useable heat. Indicating that Irish data centres have the energy potential to be heat providers in the Irish economy. This study highlighted the technical and economic aspects of prevalent cooling techniques and determined air cooling heat recovery cost can be reduced to 0.01 €/kWhth using offsetting. This is financially competitive with current heating solutions in Ireland.","PeriodicalId":282136,"journal":{"name":"Journal of Electronics Cooling and Thermal Control","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122179528","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Modeling of Subcooled Boiling Heat Transfer to Cool Electronic Components in a Micro-Channel 微通道中冷却电子元件的过冷沸腾传热建模
Journal of Electronics Cooling and Thermal Control Pub Date : 1900-01-01 DOI: 10.4236/jectc.2020.91001
Hasan Abbasinejad, R. H. Abardeh
{"title":"Modeling of Subcooled Boiling Heat Transfer to Cool Electronic Components in a Micro-Channel","authors":"Hasan Abbasinejad, R. H. Abardeh","doi":"10.4236/jectc.2020.91001","DOIUrl":"https://doi.org/10.4236/jectc.2020.91001","url":null,"abstract":"This paper aims to model a subcooled flow boiling in a vertical stainless-steel micro-channel with an upward flow in 1 mm diameter, 40 mm length and 0.325 mm thickness tube. Water has been considered as a working fluid. The heat flux varies from 600 - 750 kW·m-2, input velocity from 1 - 2 m·s-1, and the subcooled temperature varies from 59.6 - 79.6 K. The working pressure and saturation temperature are 1 atm and 372.75 K, respectively. The results show that, the flow boiling keeps the temperature of the channel wall lower and more uniform than a single-phase flow, as long as the flow boiling does not reach the dry-out point. The onset point of dry-out depends on three factors, heat flux, inlet velocity, and subcooled temperature. In addition, the dry-out occurs at a point near the channel inlet with increased heat flux and subcooled temperature. Decreasing the inlet velocity would also cause the dry-out point to shift closer to the inlet of the channel.","PeriodicalId":282136,"journal":{"name":"Journal of Electronics Cooling and Thermal Control","volume":"146 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129760708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Theoretical Study on Energy of a Gaseous System Vis-a-Vis Mass and Temperature 气态系统相对于质量和温度能量的理论研究
Journal of Electronics Cooling and Thermal Control Pub Date : 1900-01-01 DOI: 10.4236/jectc.2023.121001
S. K. Karn, Necati Demiroglu
{"title":"A Theoretical Study on Energy of a Gaseous System Vis-a-Vis Mass and Temperature","authors":"S. K. Karn, Necati Demiroglu","doi":"10.4236/jectc.2023.121001","DOIUrl":"https://doi.org/10.4236/jectc.2023.121001","url":null,"abstract":"","PeriodicalId":282136,"journal":{"name":"Journal of Electronics Cooling and Thermal Control","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126270001","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimal Thermal Insulation Thickness in Isolated Air-Conditioned Buildings and Economic Analysis 隔离式空调建筑最佳保温厚度及经济分析
Journal of Electronics Cooling and Thermal Control Pub Date : 1900-01-01 DOI: 10.4236/jectc.2020.92002
M. Mohamed
{"title":"Optimal Thermal Insulation Thickness in Isolated Air-Conditioned Buildings and Economic Analysis","authors":"M. Mohamed","doi":"10.4236/jectc.2020.92002","DOIUrl":"https://doi.org/10.4236/jectc.2020.92002","url":null,"abstract":"The removal building heat load and electrical power consumption by air conditioning system are proportional to the outside conditions and solar radiation intensity. Building construction materials has substantial effects on the transmission heat through outer walls, ceiling and glazing windows. Good thermal isolation for buildings is important to reduce the transmitted heat and consumed power. The buildings models are constructed from common materials with 0 - 16 cm of thermal insulation thickness in the outer walls and ceilings, and double-layers glazing windows. The building heat loads were calculated for two types of walls and ceiling with and without thermal insulation. The cooling load temperature difference method, CLTD, was used to estimate the building heat load during a 24-hour each day throughout spring, summer, autumn and winter seasons. The annual cooling degree-day, CDD was used to estimate the optimal thermal insulation thickness and payback period with including the solar radiation effect on the outer walls surfaces. The average saved energy percentage in summer, spring, autumn and winter are 35.5%, 32.8%, 33.2% and 30.7% respectively, and average yearly saved energy is about of 33.5%. The optimal thermal insulation thickness was obtained between 7 - 12 cm and payback period of 20 - 30 month for some Egyptian Cities according to the Latitude and annual degree-days.","PeriodicalId":282136,"journal":{"name":"Journal of Electronics Cooling and Thermal Control","volume":"188 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122853083","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信