{"title":"Modeling of Subcooled Boiling Heat Transfer to Cool Electronic Components in a Micro-Channel","authors":"Hasan Abbasinejad, R. H. Abardeh","doi":"10.4236/jectc.2020.91001","DOIUrl":null,"url":null,"abstract":"This paper aims to model a subcooled flow boiling in a vertical stainless-steel micro-channel with an upward flow in 1 mm diameter, 40 mm length and 0.325 mm thickness tube. Water has been considered as a working fluid. The heat flux varies from 600 - 750 kW·m-2, input velocity from 1 - 2 m·s-1, and the subcooled temperature varies from 59.6 - 79.6 K. The working pressure and saturation temperature are 1 atm and 372.75 K, respectively. The results show that, the flow boiling keeps the temperature of the channel wall lower and more uniform than a single-phase flow, as long as the flow boiling does not reach the dry-out point. The onset point of dry-out depends on three factors, heat flux, inlet velocity, and subcooled temperature. In addition, the dry-out occurs at a point near the channel inlet with increased heat flux and subcooled temperature. Decreasing the inlet velocity would also cause the dry-out point to shift closer to the inlet of the channel.","PeriodicalId":282136,"journal":{"name":"Journal of Electronics Cooling and Thermal Control","volume":"146 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronics Cooling and Thermal Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/jectc.2020.91001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper aims to model a subcooled flow boiling in a vertical stainless-steel micro-channel with an upward flow in 1 mm diameter, 40 mm length and 0.325 mm thickness tube. Water has been considered as a working fluid. The heat flux varies from 600 - 750 kW·m-2, input velocity from 1 - 2 m·s-1, and the subcooled temperature varies from 59.6 - 79.6 K. The working pressure and saturation temperature are 1 atm and 372.75 K, respectively. The results show that, the flow boiling keeps the temperature of the channel wall lower and more uniform than a single-phase flow, as long as the flow boiling does not reach the dry-out point. The onset point of dry-out depends on three factors, heat flux, inlet velocity, and subcooled temperature. In addition, the dry-out occurs at a point near the channel inlet with increased heat flux and subcooled temperature. Decreasing the inlet velocity would also cause the dry-out point to shift closer to the inlet of the channel.