N. F. Ismail, A. Radzol, A. Z. Zulhanip, L. N. Ismail, N. S. Mohamad Hadis, K. Y. Lee
{"title":"Effect of Etching Time Variation on Porous Si of SERS Substrate for NS1 Detection","authors":"N. F. Ismail, A. Radzol, A. Z. Zulhanip, L. N. Ismail, N. S. Mohamad Hadis, K. Y. Lee","doi":"10.1109/IECBES48179.2021.9398818","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398818","url":null,"abstract":"Dengue is a major international public health issue. Since 2015, approximately more than 100,000 reported cases with roughly 200 fatal cases are reported yearly in Malaysia. Early detection of infection during the first five days is crucial for monitoring patients to help in reducing the fatality rate. Dengue virus nonstructural 1 (DENV NS1) protein has gained a lot of interest as an early biomarker for diagnosis of DENV infection. Currently, the presence of NS1 is detected through enzyme-linked immunosorbent assay (ELISA) and immuno-chromatographic (ICT) rapid test kit using patients' blood samples which is invasive and prone to blood infection risks. Interestingly, NS1 is also discovered in saliva but at much lower sensitivity performance at ∼64.7% due to its low concentration. In this study, an ultra-sensitive and specific technique known as Surface-Enhanced Raman Spectroscopy (SERS) is proposed for the detection of low concentration of NS1 in saliva. However, SERS performance is highly dependent on the SERS substrate to be used. In this study, electro-chemical etching technique is employed to fabricate porous silicon (porous Si) with variation in structural features served as the SERS substrate base. The focus of this paper is to report on the structural variation of porous Si due to the different etching time duration. Surface characterization of the sample is investigated through the Field Emission Scanning Electron Microscope (FESEM) and energy-dispersive X-ray spectroscopy (EDX). From the top-view, cross-shaped structures are observed, while from the cross-sectional view, triangle-shaped structures are observed. The size of the formed structure increases as etching time increases. However, at the etching time of 30 min, the constructed structure starts to connect with the neighboring structure producing uneven porous Si.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"453 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125785695","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A New Model of Packaging Design Process for Pharmaceutical: A Conceptual Paper","authors":"Amalia Mukhlas, S. Nadarajan, S. Ismail","doi":"10.1109/IECBES48179.2021.9398742","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398742","url":null,"abstract":"The study related to pharmaceutical packaging has come to attention for its importance to the quality of drugs and compliance achievement. The aims of this study is to provide a conceptual view of producing a new model of pharmaceutical drug packaging design to overcome existing problems. The proposed methods for this research is to use the process mining techniques to support the construction of a new model for pharmaceutical packaging design process improvement. A case study method was selected for the methodology of the research resulted the flow of packaging design process in pharmaceutical company. The study lengthens the knowledge of drug packaging design process and concludes the importance of drug packaging design process to be investigated for compliance fulfilment purposes. This study is significant to the strong implication of drug quality and safety outcomes for the patients.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126674376","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Review on PPG Compression Techniques and Implementations","authors":"Seeba Sulekha Abdulkader, U. Qidwai","doi":"10.1109/IECBES48179.2021.9398812","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398812","url":null,"abstract":"Photoplethysmography is a simple, widely used low cost technique to acquire important diagnostic information for assessing significant physiological parameters of the human body based on the amount of light reflected from or absorbed by the body. Photoplethysmogram (PPG) signal is recognized as one of the most powerful signals in the diagnosis of variations in heart rate and pulse rate, changes in blood oxygenation levels etc. With the great advancements in communication, information technology and Internet of Things (IoT), wearable health devices have been extensively used to measure PPG signals in telemedicine, remote health monitoring, ambulatory systems and in several mobile health systems. As these small wearable medical devices are battery operated and resource-constrained, dedicated and efficient compression techniques are required to optimally manage energy and memory requirements, without jeopardizing the relevant clinical morphologies. The paper focuses on the review of the existing PPG compression techniques, type of the compression used, the basic implementation and a comparative analysis of these techniques, which could help choose a suitable technique for specific applications.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"48 60","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120942123","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nerve Signal Propagates in the Mid-Infrared to Terahertz Spectral Range by a Mechanism Consistent with Ephaptic Coupling","authors":"K. Y. J. Voon, K. Ooi, C. Ong","doi":"10.1109/IECBES48179.2021.9398778","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398778","url":null,"abstract":"Understanding of the nerve signal propagation mechanism for the myelinated nerve fiber could contribute to the improved diagnosis and medical treatment of demyelinated nerve diseases. The existing nerve propagation models have gaps in their explanation of the role of myelin sheath in the nerve signal transmission process. In our hypothesis, we propose that the myelin forms a dielectric waveguide for the nerve signal to propagate non-synaptically via an electromagnetic wave transmission mechanism. In our study, we model the myelinated nerve fiber using experimentally-obtained optical parameters, and then reproduce the experimental study of ephaptic coupling through a nerve slice through an electromagnetic full-wave simulation. The waveguide propagation performance of the nerve signal is studied within the mid-infared and terahertz spectrum, and ephaptic coupling performance is studied for different separation gaps between two nerve fibers. It is expected that the study will provide a better understanding of the nature and experimental observation of wave propagation and ephaptic coupling through a nerve fiber.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116151151","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. Khairudin, A. Nasir, L. C. Chin, Z. Mohamed, C. Y. Fook
{"title":"An Improvement for Human Intestinal Parasites Detection Methodology using $k$-Means and Fast $k$-Means Clustering","authors":"N. Khairudin, A. Nasir, L. C. Chin, Z. Mohamed, C. Y. Fook","doi":"10.1109/IECBES48179.2021.9398734","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398734","url":null,"abstract":"Helminthiases disease is one of the diseases that leads to a significant impairment in mental and physical development in children and adolescents. It entail risks if not treated properly. Hence, it is very important to have a system that can diagnose the helminthiases disease efficiently. Hence, the goal of this research is to analyse the segmentation performance for the unsupervised colour image segmentation of human intestinal parasites based on helminth between standard $k$-means (KM) clustering algorithm and Fast $k$-means (FKM) clustering algorithm through modified global contrast stretching (MGCS) enhancement technique and colour conversion based on saturation (S) component. A total of 200 helminth parasite images have been analysed with the technique proposed, which consists of 50 images for each species of Ascaris Lumbricoides Ova (ALO), Entrobious Vermicularis Ova (EVO), Hookworm Ova (HWO), and Trichuris Trichiura Ova (TTO). Both KM and FKM have succeeded in segmenting the helminth parasites with almost similar results. However, FKM has surpassed KM in terms of processing time. FKM takes 694 seconds to finish the segmentation process, as compared to KM which takes 1112 seconds. Overall, FKM clustering has successfully segment the helminth parasites with less processing time and good segmentation performance of 99.33% for accuracy, 93.36% for sensitivity of and 99.43% for specificity. The results obtained shows that the approach technique is fast and suitable to segment the helminth parasites.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124961009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Nasir, N. Khairudin, L. C. Chin, T. A. Aris, Z. Mohamed
{"title":"Enhanced $k$-Means Clustering Algorithm for Detection of Human Intestinal Parasites","authors":"A. Nasir, N. Khairudin, L. C. Chin, T. A. Aris, Z. Mohamed","doi":"10.1109/IECBES48179.2021.9398801","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398801","url":null,"abstract":"Helminthiases disease has been diagnosed as one of the most common health problems in children and adults that is caused by human intestinal parasites named helminth. An immediate diagnosis system is required for the identification and classification of helminth to avoid the development of parasites in human intestine. In response to the needs for a rapid and precise identification of helminth, this research proposes analyzing the segmentation performance analysis of unsupervised colour image segmentation of helminth parasites through enhanced $k$-means clustering (EKM) algorithm on the modified global contrast stretching (MGCS) and the modified linear contrast stretching (MLCS) enhancement techniques. By segmenting the helminth parasites using EKM clustering algorithm, the concept of variance and a new version of transferring process for clustered members are used to assist the assignation of data to the proper centre during the process of clustering, so that good segmented image can be obtained. A total of 100 helminth parasites images have been analyzed with the approach comprising of 50 images from each species of the Ascaris Lumbricoides Ova (ALO) and the Trichuris Trichiura Ova (TTO). Overall, the average results generated by the enhanced $k$-means clustering algorithm on MGCS is higher than MLCS. The proposed technique achieved 99.88% accuracy, 95.68% sensitivity alongside 99.95% specificity. Ultimately, the result demonstrates that the proposed technique is suitable for image segmentation of the helminth parasites images.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"127 6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127555536","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Novel Pathological Stroke Classification System using NSST and WLEPCA","authors":"A. Yousif, Z. Omar, U. U. Sheikh, S. A. Khalid","doi":"10.1109/IECBES48179.2021.9398808","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398808","url":null,"abstract":"Stroke is a type of cerebrovascular disease, and it is one of the leading cause of death, with over six million deaths recorded annually. In this paper, a novel scheme for an accurate multi-class stroke disease classification named Pathological Stroke Classification System (PSCS) is introduced to classify stroke disease into six classes. Features are extracted using Nonsubsampled Shearlet Transform (NSST), which decomposes the fused image into the low-frequency band and k-bands of high frequency. The low-frequency band is further analyzed using a new scheme of feature reduction and selection using weighted local energy based principal component analysis (WLEPCA). Different subsets of principal vectors are applied to three decision models, k-Nearest Neighbors (KNN), random forest (RF), and Support Vector Machine (SVM). The RF-based classifier performed better than SVM and k-NN and achieved an accuracy of 96.10%. The proposed PSCS showed a promising result in stroke classification can be considered as a reliable and robust diagnostic tool for medical practitioners.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"140 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122397503","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"CFD Generated Tracer Indicator Flow Assessment using Perfusion MRI Analysis","authors":"U. N. A. Qohar","doi":"10.1109/IECBES48179.2021.9398769","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398769","url":null,"abstract":"The emergence of multi-scale blood flow modelling from well-proven blood flow models has made the simulation of blood circulation throughout a vascular system computationally fast and accurate. It has a great potential to use both in medical science and further in clinical application for diagnosis and treatment. A replication of perfusion magnetic resonance imaging (MRI) data is an implementation that produces digital reference data with known parameters. In this paper, we present an assessment and analysis of our blood flow model generated tracer indicator using a standard perfusion MRI analysis tool for medical data. The tracer indicator flow was generated using a multi-scale blood flow model in a vascular system to replicate dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) data. The aim is to initiate a digital phantom data generator development for validating standard DCE-MRI analysis tools. The generated tracer indicator flow was qualitatively resembling the real DCE-MRI data. Based on the perfusion MRI analysis using some tracer kinetic model (TKM), the chosen simulation setups well replicated the data for blood leakage in the extravascular tissue.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124875129","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. A. Abdul Aziz, M. Saripan, N. Ibrahim, F. F. Ahmad Saad, S. Suppiah, Siti Irma Fadhilah Ismail, R. M. Razali
{"title":"Combining ADAS-Cog Assessment with Hypometabolic Region of 18F-FDG PET/CT Brain Imaging for Alzheimer's Disease Detection","authors":"S. A. Abdul Aziz, M. Saripan, N. Ibrahim, F. F. Ahmad Saad, S. Suppiah, Siti Irma Fadhilah Ismail, R. M. Razali","doi":"10.1109/IECBES48179.2021.9398848","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398848","url":null,"abstract":"The Alzheimer's disease Assessment Scale-Cognitive subscale (ADAS-Cog) is a convenient tool to perform classifications of AD at mild, moderate, and severe levels with a combination of other neuropsychological tests and SPM12. ADAS-Cog showed a fairly acceptable discrimination for moderate AD with (AUC 0.6 [95% CI, 0.171-1.029]; sensitivity=0.818, specificity=0.600, $text{PPV}=0.655$, NPV=1.000) at a cut off scores ≥37. The best cut off scores for severe AD diagnosis was ≥48 (AUC 1.000, sensitivity=1.000, specificity=0.786, $text{PPV}=0.533, text{NPV}=1.001$). However, ADAS-Cog for mild AD was undetermined (AUC 0%) with all having Montreal Cognitive Assessment (MoCA) scores ≥17. This proved that ADAS-Cog was more reliable to differentiate between severe AD and patients with less effect of cognitive decline ($mathrm{P} < 0.0001$) with PPV of 100% and NPV of 93.3% compared with MoCA (PPV of 59.3% and NPV of 82.4%). These results tested the domains of cognitive parts that showed moderate correlation was associated with the Attention domain. Consequently, the strong correlations were associated with Memory, Concentration, and Abstraction. The most important domains that have a very strong correlation with ADAS-Cog scores were Executive functions, Orientation, and Language. SPM analysis with one-sample t-test within-group analysis was done selecting the total intracranial volume (TIV), MoCA scores, and ADAS-Cog scores as the covariates. The results showed that normal control had bilateral hypometabolism area at medial frontal gyrus, left caudate, left lateral orbital gyrus, right superior frontal gyrus, and left medial frontal gyrus. As expected, all hypometabolism areas across the three AD diagnostic groups were typically detected in clusters of more than 100 voxels showing correlations with reduced activity in multiple sites of the brain. In conclusion, the ADAS-Cog with a combination of PET brain analysis had given promising results in the detection of Alzheimer's disease and measuring the cognitive domain declination.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124921682","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Chea Chia Ping, Yap Yi Ting, D. Gouwanda, A. Gopalai, Chong Yu Zheng
{"title":"The Effect of Quadriceps Contractures on Gait and its Adaptation Strategy","authors":"Chea Chia Ping, Yap Yi Ting, D. Gouwanda, A. Gopalai, Chong Yu Zheng","doi":"10.1109/IECBES48179.2021.9398766","DOIUrl":"https://doi.org/10.1109/IECBES48179.2021.9398766","url":null,"abstract":"Muscle functions may adopt abnormal activation patterns to achieve ambulation in response to the contracture in the lower extremity muscles. This study implements a forward simulation based on dynamic optimization method to investigate gait compensation strategy adopted by a person with quadriceps contracture. A simulated controller optimization environment (SCONE) was used to solve the problem using the single shooting method. The results are in good agreement with experimental data and other studies. Some significant deviations were found, which were primarily attributed to the simplification of the musculoskeletal model used. The model exhibited reduced knee and hip flexion up to 90.63% and 77.72% at the impaired limb, which were potentially related to overactivity of rectus femoris and vasti, that generated excessive knee extension moment. The unimpaired limb exerted a greater vertical ground reaction force as a mean to maintain weight-bearing stability, in which gluteus maximus contributed a significant effort to support the contralateral limb, thus leading to an increase in knee flexion by 64.25%. The findings presented in this study provides another step forward in validating a physics-based simulation independent of the experimental data. The forward dynamic optimization is expected to be a valuable clinical and engineering tool in the future.","PeriodicalId":280910,"journal":{"name":"2020 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134276345","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}