{"title":"SCADA in automated test and measurement","authors":"T. K. Mitra","doi":"10.1109/PQ.1998.710332","DOIUrl":"https://doi.org/10.1109/PQ.1998.710332","url":null,"abstract":"In the present paper, a scheme of automated test and measurement used in laboratory automation is discussed. The use of SCADA in measurement automation applications is highlighted. Automated measurement with SCADA adds many new dimensions in the measurement domain. One case study is presented in order to outline some of the features attainable under this measurement scheme.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116789898","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of algorithm for ranking of contingency and system stability","authors":"Y. Kumar, A. Shandilya","doi":"10.1109/PQ.1998.710365","DOIUrl":"https://doi.org/10.1109/PQ.1998.710365","url":null,"abstract":"This paper describes a method for identification of system instability and contingency ranking. A quadratic equation of a power network is obtained. The value of B/sup 2/-4AC of this equation is calculated for each outage. Based on this value the information about whether the system is stable or unstable, is obtained. The distance of operating point of the system from the point where the system becomes unstable, is measured. An increment in this value will show that the system is going towards instability. Having the knowledge about the stability of the system, advanced steps can be taken to prevent the instability situation, before the system becomes too unstable. This method is tested on standard IEEE test systems.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125570151","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Variable structure control of four pole voltage source inverter for active filtering of nonlinear loads in 3-phase 4-wire systems","authors":"B. Singh, Anuradha, D. Kothari, A. Chandra","doi":"10.1109/PQ.1998.710360","DOIUrl":"https://doi.org/10.1109/PQ.1998.710360","url":null,"abstract":"This paper presents the analysis of four leg voltage source inverter (VSI) used as an active filter (AF) for reactive power compensation, load balancing, harmonic elimination and neutral current compensation in three-phase four-wire nonlinear loads. Variable structure control (VSC) of the average DC bus capacitor of the AF is employed. A hysteresis rule based carrierless pulse width modulation (PWM) current control scheme is employed to generate the gating signals to the switching devices of the active filter. A set of three single-phase diode bridge rectifiers feeding a resistive-capacitive load is used for nonlinear loads on three-phase four-wire power systems. The merits of the proposed method of control are: (1) less complex and reliable active filter configuration; (2) fast controller action; (3) negligible transients in the DC bus voltage of the active filter at the time of instant load changes; (4) gradual convergence of controlled supply currents to new steady state values at the occurrence of abrupt load changes; (5) total harmonic distortion (THD) of the compensated load has been brought well below the standard harmonic specification IEEE-519 limit; (6) neutral current is reduced below 1%; and (7) simultaneous balancing of unbalanced loads. Simulated results confirm the validity of the proposed approach for three-phase (12.5 kW)/two-phase (8.3 kW)/single-phase (4.2 kW) nonlinear loads. The suggested method is expected to be widely used in future for active power filter designs produced for load compensation.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131232643","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Static VAr compensation system for industries","authors":"V. Ambarani","doi":"10.1109/PQ.1998.710374","DOIUrl":"https://doi.org/10.1109/PQ.1998.710374","url":null,"abstract":"Industrial power supply networks today are polluted by various loads connected to them and their method of control. Consumers are required to meet the stringent requirements imposed by electric utility authorities at the supply network. Hence, it is very much essential for industrial plants to have a static VAr compensator (SVC) for both reactive volt-ampere and harmonics reduction at their premises. This approach not only reduces power tariffs but also improves the quality of the power supply. This paper outlines the various types of industrial loads, their effects at the network and the methods of compensation including SVCs.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133557806","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Role of advanced instrumentation in energy management","authors":"A. Thakare, S. Ladhake","doi":"10.1109/PQ.1998.710334","DOIUrl":"https://doi.org/10.1109/PQ.1998.710334","url":null,"abstract":"This paper presents an effective way of implementing advanced instrumentation in power network energy management systems (EMS) with increased efficiency of energy utilisation. This strategic management policy stresses emphasis with significance of technological interventions. It integrates energy management orientation and practice with operational manufacturing plans and practices. The method formulates the priorities, suggesting recommendations for implementing advanced process instrumentation improvement for energy saving.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133136071","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power quality '98-a critical view","authors":"S. Subramanian, K. R. Nayar, K. Srikrishna","doi":"10.1109/PQ.1998.710384","DOIUrl":"https://doi.org/10.1109/PQ.1998.710384","url":null,"abstract":"One important contributing factor to India's slow pace of development and unsatisfactory industrial growth is the poor quality of electrical power. This power is a basic essential attribute and the advancement of any society is measured by the efficient supply and use of this precious commodity. Forced power cuts, frequent shut downs, major power breakdowns in the grid, outages of the generators and transmission lines on a large scale, unexpected blackouts of long duration, unprecedented load shedding and consequent pitiable state of voltage and frequency regulations, are some of the regularly experienced flaws. A typical 1991 IBM study has shown that even in the US, a computer faces as many as one hundred and twenty power problems per week. Power quality envisages an economic, stable, reliable, secure and safe power transfer in a power system. The authors discuss these aspects as well as contingency analysis and protection.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"131 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114683851","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fuzzy control algorithm for universal active filter","authors":"B.N. Singh, H. Chandra, K. Al-haddad, B. Singh","doi":"10.1109/PQ.1998.710347","DOIUrl":"https://doi.org/10.1109/PQ.1998.710347","url":null,"abstract":"In this paper, a fuzzy algorithm is employed to control a three-phase unified power quality conditioner (UPQC). The UPQC is an active filter (AF) and it compensates the reactive power and harmonics in both the voltage and current caused by nonlinear loads. The UPQC makes use of two back-to-back connected IGBT-based voltage source inverters (VSIs) with a common DC bus. One inverter is connected in series while other is placed in shunt with the nonlinear load. The shunt inverter works as a current source and compensates current harmonics caused by nonlinear loads. The series inverter works as a voltage source and helps in compensating the voltage harmonics caused by nonlinear loads. A diode bridge rectifier feeding an R-L load is considered as a nonlinear current load while a source of voltage harmonics is considered in shunt with the load. With a view to examining the steady state and transient performance of the UPQC, a suitable mathematical model of the system is developed. The capability of the UPQC is demonstrated in the filtering of voltage and current harmonics along with the reactive power compensation of nonlinear loads. Simulated results are given and discussed in detail. Experimental results are also given.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132327324","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A universal active power filter for single-phase reactive power and harmonic compensation","authors":"B. Singh, K. Al-haddad, A. Chandra","doi":"10.1109/PQ.1998.710359","DOIUrl":"https://doi.org/10.1109/PQ.1998.710359","url":null,"abstract":"In modern power distribution systems, the majority of loads draw reactive power and/or harmonic currents from the AC source along with main active power currents. These nonunity power factor linear and nonlinear loads cause low efficiency of the power supply system, poor power factor, destruction of other equipment due to excessive stresses and EMI problems. Active filters have been considered an effective solution to reduce these problems. This paper presents an active power filter (APF) based on a simple control technique to provide reactive power and harmonics compensation for linear and nonlinear single-phase loads. A voltage source inverter with carrierless hysteresis PWM current control is used to form the APF. A simple PI DC bus voltage controller with a reduced energy storage capacitor is employed in the APF. A set of lagging/leading power factor linear loads and a diode rectifier-fed capacitive load and AC voltage regulator-fed inductive load as nonlinear loads are used to demonstrate the effectiveness of the proposed APF for reactive power and harmonic compensation. The detailed steady-state and dynamic performances of the APF are presented and discussed in brief.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122272400","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power quality park prospects in Mumbai, India","authors":"B. Banerjee, S. Joglakar, W.A. Moncrief","doi":"10.1109/PQ.1998.710328","DOIUrl":"https://doi.org/10.1109/PQ.1998.710328","url":null,"abstract":"BSES, Ltd. of Mumbai, Maharastra, India and EPRI have investigated the state of power quality in that electric utility. As a result, plans are offered for a power quality park, with special distribution features to maximize customer productivity.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"34 11","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114132896","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A need to review total harmonic distortion measurement in power systems","authors":"G. Mohanraj","doi":"10.1109/PQ.1998.710370","DOIUrl":"https://doi.org/10.1109/PQ.1998.710370","url":null,"abstract":"Introduction of thyristor drives and different types of loading pattern have brought in a lot of distortion in the waveforms, beyond the conventionally accepted 3rd, 5th, 7th, 11th & 13th harmonic disturbances. For analysis, the waveforms are decoded by harmonic analysers into various harmonic elements, so that the added sum gives the final waveform. This basic principle is based on Fourier series of estimation. The total harmonic distortion (THD) is conventionally mentioned as THD.%=(/spl radic/(V2/sup 2/+V3/sup 2/....VN/sup 2//V1/sup 2/))/spl times/100% As this value does not tally with the working parameters for comparison, the standards like IEEE 519, G 5/3 etc. have adopted limitations by direct summation. This paper presents a need for reviewing both so that the measurements can be compared easily with the working conditions. This is based on studies conducted at various sites during the last 8 years. Some of the waveforms recorded are presented here. This would easily pave a way for providing simpler protection in the power distribution systems.","PeriodicalId":280807,"journal":{"name":"Power Quality '98","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133337096","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}