2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)最新文献

筛选
英文 中文
Validation of Algorithms to Estimate Distribution Network Characteristics Using Power-Hardware-in-the-Loop Configuration 利用电源-硬件在环配置估计配电网特性的算法验证
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-10-23 DOI: 10.1109/AMPS.2017.8078349
Maria Segovia, Islam Rohouma, Q. Hong, S. Chrétien, P. Clarkson
{"title":"Validation of Algorithms to Estimate Distribution Network Characteristics Using Power-Hardware-in-the-Loop Configuration","authors":"Maria Segovia, Islam Rohouma, Q. Hong, S. Chrétien, P. Clarkson","doi":"10.1109/AMPS.2017.8078349","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078349","url":null,"abstract":"Distribution system operators (DSOs) require accurate knowledge of the status of the network in order to ensure the continuity and quality of power supply. In this context, the National Physical Laboratory (NPL) and the Power Network Demonstrations Centre (PNDC) have been working together in the development and validation of optimal sensor placement and network topology estimation algorithms. This paper presents the description of two of these algorithms as well as the topology configuration of the PNDC distribution network considered to gather measurements for the validation of the algorithms. A Power-Hardware-in-the-Loop (P-HiL) configuration has been used as the testbed, where a number of physical measurement devices are installed in the physical network and an extended number of devices are virtually installed in the simulate network. The applications of the proposed algorithms to the measurements along with results from the P-HiL tests are presented in the paper.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115617420","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Low-Cost Battery Monitoring by Converter-Based Electrochemical Impedance Spectroscopy 基于变换器的电化学阻抗谱低成本电池监测
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-10-23 DOI: 10.1109/AMPS.2017.8078334
R. Ferrero, Chao Wu, A. Carboni, S. Toscani, M. Angelis, H. George-Williams, E. Patelli, P. Pegoraro
{"title":"Low-Cost Battery Monitoring by Converter-Based Electrochemical Impedance Spectroscopy","authors":"R. Ferrero, Chao Wu, A. Carboni, S. Toscani, M. Angelis, H. George-Williams, E. Patelli, P. Pegoraro","doi":"10.1109/AMPS.2017.8078334","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078334","url":null,"abstract":"The use of batteries and other electrochemical devices in modern power systems is rapidly increasing, with stricter requirements in terms of cost, efficiency and reliability. Innovative monitoring solutions are therefore urged to allow a successful development of a wide range of emerging applications, including electric vehicles and large-scale energy storage to support renewable energy generation. Presently, a huge gap still exists between the accurate and sophisticated monitoring techniques commonly employed in laboratory tests, on the one hand, and the simple and rough solutions available in most commercial applications, on the other hand. The objective of this paper is therefore to contribute to the development of low-cost but accurate solutions for commercial battery condition monitoring, by proposing an embedded system that combines real-time digital signal processing with the high computational power and user friendly interface of a modern computer, at a cost comparable to a simple micro-controller. In more detail, the paper focuses on electrochemical impedance spectroscopy on a battery performed by a DC-DC power converter, and it explains how the proposed low-cost off-the-shelf hardware can control the converter, acquire the measurement signals, accurately process them in the time and frequency domains, and estimate the result uncertainty in real-time, which is necessary to promptly and reliably detect any variation in the battery condition.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117091303","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Employment of Interpolated DFT-based PMU Algorithms in Three-Phase Systems 基于插值dft的PMU算法在三相系统中的应用
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-10-23 DOI: 10.1109/AMPS.2017.8078336
R. Ferrero, P. Pegoraro, S. Toscani
{"title":"Employment of Interpolated DFT-based PMU Algorithms in Three-Phase Systems","authors":"R. Ferrero, P. Pegoraro, S. Toscani","doi":"10.1109/AMPS.2017.8078336","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078336","url":null,"abstract":"Phasor measurement units (PMUs) are the key measurement devices of modern power networks monitoring systems. The high accuracy and fast reporting rates required for PMU implementations ask for improvements in both hardware and software solutions. Depending on the characteristics of the monitored voltages and currents, the accuracy of PMU algorithms may represent the main contribution to the overall measurement performance. For this reason, research is ongoing in the field of signal processing techniques for phasor and frequency estimation. In this context, Interpolated Discrete Fourier Transform (IpDFT) is one of the most interesting techniques, mainly because it allows accurate measurements under off-nominal frequency conditions while preserving simplicity and computational efficiency. In this paper, the applicability of IpDFT to three-phase signals that are typical of power networks is discussed. Then, it is proposed to combine the advantages of IpDFT with those of the Space Vector approach for positive sequence synchrophasor and frequency measurements.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127465735","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Challenges for Smart Electricity Meters due to Dynamic Power Quality Conditions of the Grid: A Review 电网动态电能质量条件对智能电表的挑战综述
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-09-20 DOI: 10.1109/AMPS.2017.8078345
R. Q. Cetina, A. Roscoe, P. Wright
{"title":"Challenges for Smart Electricity Meters due to Dynamic Power Quality Conditions of the Grid: A Review","authors":"R. Q. Cetina, A. Roscoe, P. Wright","doi":"10.1109/AMPS.2017.8078345","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078345","url":null,"abstract":"During the last few years, Smart Electricity Meters have been deployed in several countries all around the world, replacing the trustable Electromechanical meter and even other electronic meters. Since the early deployments, many concerns and complaints from customers which do not trust Smart Meters accuracy have appeared. As a result, researchers of different institutions have been testing electricity meters under distorted waveform conditions and proposing methods to calibrate such meters in a more representative real world operative conditions. Applicable accuracy standards and regulations indicate a maximum distortion factor of 3% of the sinusoidal waveform for voltage and current during the calibration, which is not representative of many modern dynamic power quality scenarios. New tests and recommendations have been issued by regulatory bodies, but they are still not mandatory for meters to be certified. With many changes upcoming in the near future for the electrical Smart Grid like the inclusion of renewables, increasing non-linear loads, electric charging vehicles and other emerging technologies, the power quality conditions of the grid is expected to be significantly affected. In this paper, a review of the current and upcoming challenges for the smart meters is presented.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115156298","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 27
The Case for Redefinition of Frequency and ROCOF to Account for AC Power System Phase Steps 重新定义频率和ROCOF以考虑交流电力系统相位步进的情况
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-09-20 DOI: 10.1109/AMPS.2017.8078330
A. Roscoe, A. Dyśko, B. Marshall, M. Lee, H. Kirkham, G. Rietveld
{"title":"The Case for Redefinition of Frequency and ROCOF to Account for AC Power System Phase Steps","authors":"A. Roscoe, A. Dyśko, B. Marshall, M. Lee, H. Kirkham, G. Rietveld","doi":"10.1109/AMPS.2017.8078330","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078330","url":null,"abstract":"All conventional techniques for measuring frequency result in large deviations to the perceived or calculated frequency when the AC waveform undergoes a phase step. The deviation magnitude and duration are dependent on the phase step magnitude, and the applied windowing/filtering. Such phase steps do occur in the power system, and the erroneous frequency calculation can result in inappropriate reactions by some rapidly-responding control and protection systems. If the frequency measurand is further differentiated to ROCOF (Rate of Change of Frequency), the excursion magnitudes can become far larger than any normally expected values of ROCOF. This paper discusses the meaning of the terms frequency and ROCOF, and presents a modified concept of frequency and ROCOF. This is done by allowing rapid phase steps to be disaggregated from frequency in the AC waveform model equation. This allows new measurands “underlying frequency”, and “underlying ROCOF” to be defined, as a pair of linked parameters, independent from a separate dynamic phase parameter. These new measurands have the potential to offer much more useful and stable information to be sent to fast-acting control and protection systems, than the existing measurands of AC frequency and ROCOF, particularly during fault events and large switching or disconnection events.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"149 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122457856","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 45
Voltage Transducers Testing Procedure Based on the Best Linear Approximation 基于最佳线性逼近的电压传感器测试程序
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-09-01 DOI: 10.1109/AMPS.2017.8078326
M. Faifer, C. Laurano, R. Ottoboni, S. Toscani, M. Zanoni
{"title":"Voltage Transducers Testing Procedure Based on the Best Linear Approximation","authors":"M. Faifer, C. Laurano, R. Ottoboni, S. Toscani, M. Zanoni","doi":"10.1109/AMPS.2017.8078326","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078326","url":null,"abstract":"Attention towards power quality issues in distribution grids has increased noticeably in the last decade. Power quality assessment and monitoring require voltage transducers capable of measuring both fundamental and harmonics with adequate accuracy. Beside this, a systematic but simple procedure for evaluating the measurement performance of voltage transducers, able to quantify the impact of linear and nonlinear effects separately has not been proposed yet. In this paper, a testing method based on the concept of Best Linear Approximation (BLA) is introduced. The excitation signals resemble the voltage waveforms typically found in distribution networks, while the impact of noise and nonlinearity is evaluated in terms of sample variances. The approach is applied to the model of a typical voltage transformer by means of numerical simulations.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117128155","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
A Novel Combined Alternate Current Sensor for Variable-Frequency Scenario 一种新型变频组合式交流电流传感器
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-09-01 DOI: 10.1109/AMPS.2017.8078342
F. Du, Z. Liu, Weigang Chen, Y. Zhuo, M. Anheuser
{"title":"A Novel Combined Alternate Current Sensor for Variable-Frequency Scenario","authors":"F. Du, Z. Liu, Weigang Chen, Y. Zhuo, M. Anheuser","doi":"10.1109/AMPS.2017.8078342","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078342","url":null,"abstract":"Recent developments of variable frequency applications have accelerated the demand to look at the measurement technology on variable frequency signals. Most low voltage (LV) circuit breakers are designed to operate at a fixed frequency. Therefore, it is necessary to propose a variable-frequency measuring concept for LV protection devices. In this paper, we propose a novel combined alternate current sensor based on the Rogowski coil and iron-cored current transformer (CT), which can provide a high accuracy within the frequency range of 0.2Hz-200Hz and amplitude (up to several hundreds of kA). For the iron core CT, it covers the small current at ultra low frequency. For the Rogowski coil, it covers other current levels. In order to achieve the performance, an improved compensation method for the iron core CT is used to obtain higher accuracy and a combined integration method for the Rogowski coil is applied to expand the band of frequency, especially at ultra low frequency.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128481654","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
NB PLC and Software Defined Networking for Smart Grid Applications 智能电网应用的NB PLC和软件定义网络
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-09-01 DOI: 10.1109/AMPS.2017.8078348
S. Rinaldi, Federico Bonafini, P. Ferrari, A. Flammini, D. D. Cara, N. Panzavecchia, G. Tinè, A. Cataliotti, V. Cosentino, S. Guaiana
{"title":"NB PLC and Software Defined Networking for Smart Grid Applications","authors":"S. Rinaldi, Federico Bonafini, P. Ferrari, A. Flammini, D. D. Cara, N. Panzavecchia, G. Tinè, A. Cataliotti, V. Cosentino, S. Guaiana","doi":"10.1109/AMPS.2017.8078348","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078348","url":null,"abstract":"During the last years, the installation of Distributed Energy Resources (DERs) and the expected diffusion of Electrical Vehicles (EVs), is increasing the complexity of the distribution grid, making the management of the grid operated by Distribution System Operators (DSOs) more difficult. The Smart Grid approach tries to provide a response to these troubles, by means of a strong interaction between the power grid and Information and Communication Technology (ICT) infrastructures. The drawback of this approach is an increase in the management effort of the ICT infrastructures, for which the DSO are not prepared. Software Defined Networking (SDN) is an approach developed to manage complex ICT infrastructures of datacenters, and its main target is to simplify the network configuration and management. The Smart Grid could benefit from the use of an SDN approach for the management of the communication infrastructure, as highlighted from previous research works. The target of this paper is to present a real case application of the SDN technology for the management of DERs over the distribution grid. The communication between electrical devices placed along the power grid and the secondary substations is provided by using Modbus RTU protocol over narrowband power line communication (NB-PLC). The preliminary characterization highlights that the Round Trip Time (RTT) on NB-PLC segment is affected by the used frequency band and by the modulation scheme. In the worst case (i.e., transmission at 72 kHz and a BPSK coded modulation, for a total data rate of 4.9 kb/s), the RTT is in the order of 140 ms, compatible with the requirements of the application.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115481055","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A Testbed for the Experimental Characterization of Estimation Algorithms for Phasor Measurement Units 相量测量单元估计算法的实验表征试验平台
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-09-01 DOI: 10.1109/AMPS.2017.8078341
D. Gallo, C. Landi, M. Luiso, Pietro Tosato, D. Macii, D. Brunelli
{"title":"A Testbed for the Experimental Characterization of Estimation Algorithms for Phasor Measurement Units","authors":"D. Gallo, C. Landi, M. Luiso, Pietro Tosato, D. Macii, D. Brunelli","doi":"10.1109/AMPS.2017.8078341","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078341","url":null,"abstract":"The proliferation of estimation algorithms for Phasor Measurement Units (PMUs) makes performance analysis and comparison between different techniques a challenging task. This paper presents a testbed conceived to perform a flexible and accurate characterization of different estimation algorithms in various testing conditions reported in the IEEE Standard C37.118.1-2011 and its Amendment C37.118.1a-2014 while including additional uncertainty contributions, such as those due to measurement transducers, data acquisition and synchronization modules, which can be hardly considered in simulations. The testbed relies on a Fluke calibrator 6135A/PMUCAL and a PXI system equipped with data acquisition boards, a synchronization module, voltage and current transducers and a Virtual Instrument (VI) developed in LabVIEW. The testbed is remotely controlled and automated through Ethernet and GPIB interfaces. Different estimation algorithms can be easily included as dynamic link libraries (DLL) and replaced in the LabVIEW application by using a common function wrapper. The structure of the proposed testbed is particularly useful in development and prototyping stages.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121375638","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
The Improvement of System Damping by Grid Integration of PV Energy Sources 光伏能源并网改善系统阻尼
2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Pub Date : 2017-09-01 DOI: 10.1109/AMPS.2017.8078332
J. Hattingh, J. Rens, Gerhard Botha
{"title":"The Improvement of System Damping by Grid Integration of PV Energy Sources","authors":"J. Hattingh, J. Rens, Gerhard Botha","doi":"10.1109/AMPS.2017.8078332","DOIUrl":"https://doi.org/10.1109/AMPS.2017.8078332","url":null,"abstract":"The impact of static generators on power system small signal stability is evaluated by means of micro-synchrophasors collected in a distribution system using a class A Power Quality recorder that also functions as a Phasor Measurement Unit. Distributed generation of renewable energy could be a possible concern to the traditional power system where inertia of rotating generators is available during system disturbances. Field data is used to demonstrate that large grid-connected photovoltaic energy sources can improve system damping, mitigating some of the concerns on introducing static generation into power systems.","PeriodicalId":273139,"journal":{"name":"2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125193803","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书