{"title":"Comparison of Radiation Dose of Abdomen Pelvis CT with Automatic Exposure Control according to Different Scout Image Acquisition: Standard and Obese Phantom Study","authors":"Yong-min Kim, K. Lee","doi":"10.31320/jksct.2021.23.2.1","DOIUrl":"https://doi.org/10.31320/jksct.2021.23.2.1","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133070754","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Quantitative analysis of image quality and radiation dose of ultra low dose chest CT using AI-based deep learning reconstruction algorithm ‘AiCE’","authors":"Dong-Hee Ko, Soo-Young Lee, H. Shim, P. Jeon","doi":"10.31320/jksct.2021.23.2.21","DOIUrl":"https://doi.org/10.31320/jksct.2021.23.2.21","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129460060","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Myeong-Jin Kim, Inho Choi, M. Jung, Hangyu Song, W. Yang
{"title":"A Study on the Image Quality and Dose Reduction According to the Variation of Tube Voltage and Scout Method in Chest CT","authors":"Myeong-Jin Kim, Inho Choi, M. Jung, Hangyu Song, W. Yang","doi":"10.31320/jksct.2021.23.2.39","DOIUrl":"https://doi.org/10.31320/jksct.2021.23.2.39","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125009220","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"When is the Optimal Time to Control High Heart Rate with Ivabradine during Coronary CT Angiography?","authors":"Soo-Jin Nam, U-In Jeon, Woong-Ki Kim, S. Ko","doi":"10.31320/jksct.2021.23.2.29","DOIUrl":"https://doi.org/10.31320/jksct.2021.23.2.29","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114328276","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Chang-Su Ko, In-Wan Cho, Ji-Won Kang, Woo-Jun Jeong, Hoon Song
{"title":"Comparative Analysis and Usefulness by Quantitative Evaluation of Deep Learning Image Reconstruction and Adaptive Statistical Iterative Reconstruction-V in Aortic Vessels CT","authors":"Chang-Su Ko, In-Wan Cho, Ji-Won Kang, Woo-Jun Jeong, Hoon Song","doi":"10.31320/jksct.2021.23.2.9","DOIUrl":"https://doi.org/10.31320/jksct.2021.23.2.9","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"115 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122222346","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jin-Seok Park, Young-Kyoon Kim, W. Chang, Yoon-Chul Nam, Mi-Sub Ahn, J. Yoon
{"title":"Evaluation of Usefulness of the Half Scan in CT Guided Interventional Radiology","authors":"Jin-Seok Park, Young-Kyoon Kim, W. Chang, Yoon-Chul Nam, Mi-Sub Ahn, J. Yoon","doi":"10.31320/jksct.2019.21.1.11","DOIUrl":"https://doi.org/10.31320/jksct.2019.21.1.11","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134561256","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Secure Patient Safety and Improve Exposure Defense during Mobile CT Examination for Device Development","authors":"Sung-Kun Bae, Sung Yeong Lee, Jae Min Lee","doi":"10.31320/jksct.2019.21.1.37","DOIUrl":"https://doi.org/10.31320/jksct.2019.21.1.37","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125830388","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimization of Radiation Dose and Image Quality using ADMIRE Algorithm and Quantitative Evaluation","authors":"Bumgu Son, Kibaek Lee, Hee-Don Yoon","doi":"10.31320/jksct.2019.21.1.1","DOIUrl":"https://doi.org/10.31320/jksct.2019.21.1.1","url":null,"abstract":"목적: 최신 반복적 재구성법인 ADMIRE 알고리즘을 물질의 종류, 검사 조건, 적용 단계에 관하여 정량적으로 평가하고 이를 활용하여 환자 피폭선량과 영상의 질을 최적화 하고자 한다. \u0000대상 및 방법: 증류수와 조영제의 혼합용액으로 밀도가 다른 네 종류의 물질 A(30~40 HU), B(60~70 HU), C(100~110 HU), D(200~210...","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115397103","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yeong-Han Kim, T. Nam, Sung-Kwan Kim, H. Chae, soon-ahn kwon, Chang-min Dae
{"title":"The Effect of the Change in the Volume and the Wall Thickness of Stomach by Adjusting Dosage of Water According to Gender and Weight in Stomach CT.","authors":"Yeong-Han Kim, T. Nam, Sung-Kwan Kim, H. Chae, soon-ahn kwon, Chang-min Dae","doi":"10.31320/jksct.2019.21.1.25","DOIUrl":"https://doi.org/10.31320/jksct.2019.21.1.25","url":null,"abstract":"","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132970508","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}