Heike Leutheuser, S. Doelfel, D. Schuldhaus, Samuel J. Reinfelder, B. Eskofier
{"title":"Performance Comparison of Two Step Segmentation Algorithms Using Different Step Activities","authors":"Heike Leutheuser, S. Doelfel, D. Schuldhaus, Samuel J. Reinfelder, B. Eskofier","doi":"10.1109/BSN.2014.37","DOIUrl":"https://doi.org/10.1109/BSN.2014.37","url":null,"abstract":"Insufficient physical activity is the 4th leading risk factor for mortality. The physical activity of a person is reflected in the walking behavior. Different methods for the calculation of the accurate step number exists and most of them are evaluated using different walking speeds measured on a treadmill or using a small sample size of overground walking. In this paper, we introduce the BaSA (Basic Step Activities) dataset consisting of four different step activities (walking, jogging, ascending, and descending stairs) that were performed under natural conditions. We further compare two step segmentation algorithms (a simple peak detection algorithm vs. subsequence Dynamic Time Warping (sDTW)). We calculated a multivariate Analysis of Variance (ANOVA) with repeated measures followed by multiple dependent t-tests with Bonferroni correction to test for significant differences in the two algorithms. sDTW performed equally good compared to the peak detection algorithm, but was not considerably better. In further analysis, continuous, real walking signals with transitions from one step activity to the other step activity should be considered to investigate the adaptability of these two step segmentation algorithms.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115584561","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimal Design for Symbiotic Wearable Wireless Sensors","authors":"P. Bagade, Ayan Banerjee, S. Gupta","doi":"10.1109/BSN.2014.31","DOIUrl":"https://doi.org/10.1109/BSN.2014.31","url":null,"abstract":"Sensors aesthetically embedded in accessories such as jewelry, piercings or contact lenses are being proposed recently. These symbiotic wearable wireless sensors are envisioned to operate on scarce harvested energy resources from the human body. In addition to the hardware and software constraints arising from the form-factor and low energy operations, there are safety requirements such as avoidance of physical injury. The design implications of these requirements are non-intuitive and may involve estimation of human physiological dynamics. The physical impact of a sensor operation can be controlled by appropriate design of multiple sensor components such as processor, radio, and optimization of data algorithm. For example, the risk of thermal injury to tissue can be reduced by limiting the sensing frequency, the computation power, and the radio duty cycle of body worn sensor. Hence, it is a challenging task to trace back a cause of a physical impact to hardware and software design decisions in a sensor. This paper proposes a novel non-linear optimization framework to consider safety and sustainability requirements that depend on the human physiology and derive system level design parameters of a sensor. We demonstrate our methodology using three case studies: a) continuously monitoring ECG sensor sustained by body heat, b) thermally safe network of implanted sensors, and c) infusion pump control algorithm to avoid hypoglycemia.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"94 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127072987","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wearable Localization by Particle Filter with the Assistance of Inertial and Visual Sensors","authors":"Sz-Pin Huang, J. Qiu, Chi-Chung Lo, Y. Tseng","doi":"10.1109/BSN.2014.15","DOIUrl":"https://doi.org/10.1109/BSN.2014.15","url":null,"abstract":"Indoor positioning has been intensively studied recently due to the exploding demands of indoor mobile applications. While numerous works have employed wireless signals or dead-reckoning techniques, wearable computing poses new opportunities as well as challenges to the localization problem. This research studies the wearable localization problem by proposing a particle filter-based scheme to fuse the inputs from wearable inertial and visual sensors on human body. Specifically, the filter takes inertial measurements, wireless signals, visual landmarks, and indoor floor plans as inputs for location tracking. The inertial signals imply human body movements, the wireless signals indicate a rough absolute region inside a building, while the visual landmarks provide relative angles viewed from particular positions to these markers. Furthermore, a head-mounted display provides intuitive and friendly interfaces to users. The proposed system has also been prototyped and tested in our campus, and the experiments demonstrate an average localization error of about one meter.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134395381","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Detection of Gait Phases Using Orient Specks for Mobile Clinical Gait Analysis","authors":"Robert L. Evans, D. Arvind","doi":"10.1109/BSN.2014.22","DOIUrl":"https://doi.org/10.1109/BSN.2014.22","url":null,"abstract":"This paper presents a hybrid method based on a feed-forward neural network (FNN) embedded in a hidden Markov model (HMM), for detecting phases in a gait cycle, based on data from inertial sensors attached to the lower body. The method was validated against the ground truth obtained concurrently from a Vicon optical motion capture system for five volunteers. The method was characterised using metrics such as sensitivity and specificity for sensor placements, and gait analysis. The results demonstrate that the proposed method is accurate within 23 milliseconds with the added advantages of mobility afforded by wireless sensors and the flexibility of the classification method.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133145984","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Caldara, D. Comotti, M. Galizzi, P. Locatelli, V. Re, D. Alimonti, M. Poloni, M. Rizzetti
{"title":"A Novel Body Sensor Network for Parkinson's Disease Patients Rehabilitation Assessment","authors":"M. Caldara, D. Comotti, M. Galizzi, P. Locatelli, V. Re, D. Alimonti, M. Poloni, M. Rizzetti","doi":"10.1109/BSN.2014.28","DOIUrl":"https://doi.org/10.1109/BSN.2014.28","url":null,"abstract":"A miniaturized wireless Attitude and Heading Reference System has been developed with the primary purpose to achieve a body sensor network for motor performance quantitative analysis of Parkinson's disease patients during rehabilitation sessions. The paper describes the performance of the single node, the peculiarities of the developed wearable network and the custom software developed specifically for the Extended Timed-Up-and-Go test. An experimental protocol on Parkinson's Disease patients is currently ongoing. This paper reports the preliminary results, involving 13 patients (mean age 64.6±9) with a moderate disease level and 4 controls (mean age 64.3±4). The data taken during rehabilitation exercise have been analyzed and outcomes are discussed.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116905455","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. Alshurafa, J. Eastwood, M. Pourhomayoun, Suneil Nyamathi, Lily Bao, B. Mortazavi, M. Sarrafzadeh
{"title":"Anti-Cheating: Detecting Self-Inflicted and Impersonator Cheaters for Remote Health Monitoring Systems with Wearable Sensors","authors":"N. Alshurafa, J. Eastwood, M. Pourhomayoun, Suneil Nyamathi, Lily Bao, B. Mortazavi, M. Sarrafzadeh","doi":"10.1109/BSN.2014.38","DOIUrl":"https://doi.org/10.1109/BSN.2014.38","url":null,"abstract":"In remote health monitoring of patient's physical activity, ensuring correctness and authenticity of the received data is essential. Although many activity monitoring systems, devices and techniques have been developed, preventing patient cheating of an activity monitor has been a primarily unaddressed challenge across the board. Patients can manually shake an activity monitor device (sensor) with their hand and watch their physical activity points or rewards increase, we define this as \"self-inflicted\" cheating. A second type of cheating, \"impersonator\" cheating, is when subjects hand the activity sensor over to a friend or second party to wear and perform physical activity on their behalf. In this paper, we propose two novel methods based on classification algorithms to address the cheating problems. The first classification framework improves the correctness of our data by detecting self-inflicted cheatings. The second technique is an advanced classification scheme that extracts and learns unique patient-specific activity patterns from prior data collected on a patient to distinguish the true subject from an impersonator. We tested our proposed techniques on Wanda, a remote health monitoring system used in our Women's Heart Health study of 90 African American women at risk of cardiovascular disease. We were able to distinguish cheating from other physical activities such as walking and running, as well as other common activities of daily living such as driving and playing video games. The self-inflicted cheating classifier achieved an accuracy of above 90% and an AUC of 99%. The impersonator cheater framework results in an average accuracy of above 90% and an average AUC of 94%. Our results provide insight into the randomness of cheating activities, successfully detects cheaters, and attempts to build more context-aware remote activity monitors that more accurately capture patient activity.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129585533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of TOA-Based Ranging Accuracy of a Miniature Ultra-Wideband Antenna for Human Motion Capture Applications","authors":"Manmohan Sharma, C. Parini, A. Alomainy","doi":"10.1109/BSN.2014.13","DOIUrl":"https://doi.org/10.1109/BSN.2014.13","url":null,"abstract":"This paper presents an investigative study of the ranging capabilities of a miniature tapered-slot UWB antenna and an analysis of the influence of the human body on the accuracy of range estimates. The study involves determining how precisely the point-to-point distance between two identical tapered-slot antennas can be deduced through the signal Time-of-Flight from the transmitting antenna to the receiving antenna. Channel Impulse Response and peak detection techniques have been used for range estimation. Both on-body and free-space scenarios have been considered for this study. Very high accuracy is observed in calculating the range estimates between the two antennas, both when the antennas are in free-space and when placed on the human body.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129115336","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ching-Mei Chen, R. Kwasnicki, Benny P. L. Lo, Guang-Zhong Yang
{"title":"Wearable Tissue Oxygenation Monitoring Sensor and a Forearm Vascular Phantom Design for Data Validation","authors":"Ching-Mei Chen, R. Kwasnicki, Benny P. L. Lo, Guang-Zhong Yang","doi":"10.1109/BSN.2014.33","DOIUrl":"https://doi.org/10.1109/BSN.2014.33","url":null,"abstract":"Photoplethysmography (PPG) is a well established method of measuring Heart Rate Variability (HRV) and blood oxygen saturation (SpO2) at the fingers, forehead or other areas of the body where pulsatile flow is present. However, obtaining reliable tissue oxygen saturation (StO2) from optical devices is more challenging due to a number of factors including motion and signal-to-noise ratio. Instrumentation of such devices as miniaturised wearable platforms would allow the device to be worn freely by patients in hospitals or at home. The purposes of this paper are to present: 1) a bespoke, low power StO2 sensor, 2) preliminary comparison to a commercially available photospectroscopy and laser Doppler machine (Oxygen 2 See, Medizintechnik, LEA, Germany) using a pressure cuff forearm ischaemia model, and 3) validation of fluid (blood) flow/relative haemoglobin measurements using a novel forearm phantom.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115770732","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Ahmadi, Edmond Mitchell, F. Destelle, Marc Gowing, N. O’Connor, C. Richter, Kieran Moran
{"title":"Automatic Activity Classification and Movement Assessment During a Sports Training Session Using Wearable Inertial Sensors","authors":"A. Ahmadi, Edmond Mitchell, F. Destelle, Marc Gowing, N. O’Connor, C. Richter, Kieran Moran","doi":"10.1109/BSN.2014.29","DOIUrl":"https://doi.org/10.1109/BSN.2014.29","url":null,"abstract":"Motion analysis technologies have been widely used to monitor the potential for injury and enhance athlete performance. However, most of these technologies are expensive, can only be used in laboratory environments and examine only a few trials of each movement action. In this paper, we present a novel ambulatory motion analysis framework using wearable inertial sensors to accurately assess all of an athlete's activities in an outdoor training environment. We firstly present a system that automatically classifies a large range of training activities using the Discrete Wavelet Transform (DWT) in conjunction with a Random forest classifier. The classifier is capable of successfully classifying various activities with up to 98% accuracy. Secondly, a computationally efficient gradient descent algorithm is used to estimate the relative orientations of the wearable inertial sensors mounted on the thigh and shank of a subject, from which the flexion-extension knee angle is calculated. Finally, a curve shift registration technique is applied to both generate normative data and determine if a subject's movement technique differed to the normative data in order to identify potential injury related factors. It is envisaged that the proposed framework could be utilized for accurate and automatic sports activity classification and reliable movement technique evaluation in various unconstrained environments.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131491802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Piezoelectric Pulse Generator and FM Transmission Circuit for Self-Powered BSN Nodes","authors":"Hao Jiang, M. Kiziroglou, D. Yates, E. Yeatman","doi":"10.1109/BSN.2014.19","DOIUrl":"https://doi.org/10.1109/BSN.2014.19","url":null,"abstract":"This paper presents a piezoelectric pulse generator for body sensing and wireless transmission. A steel rolling ball is used as a proof mass to provide a smooth motion excited by non-harmonic external vibrations. In addition, the proof mass in this prototype is implemented to achieve both impulse excitation of the piezoelectric cantilever by magnetic coupling, and self-synchronous switching. A new actuation mechanism to pre-bias a piezoelectric cantilever passively is demonstrated which enhances the energy extracted. Experimental results are presented to compare between the pre-biased and unbiased cases, showing 76% more extracted energy in the pre-biased case. A transmitter is designed which encodes the sensor signal by frequency modulation, to demonstrate the feasibility of building a self-powered body sensor network (BSN) node based on the demonstrated piezoelectric pulse generator.","PeriodicalId":270751,"journal":{"name":"2014 11th International Conference on Wearable and Implantable Body Sensor Networks","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116333106","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}