Keep on running: predicting battery performance by cell approach 继续运行:通过电池方法预测电池性能
A. S. Clegg
{"title":"Keep on running: predicting battery performance by cell approach","authors":"A. S. Clegg","doi":"10.1109/INTLEC.1992.268409","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268409","url":null,"abstract":"It is necessary to monitor valve-regulated lead-acid batteries at an individual cell/bloc level to ensure that their state of charge and state of health are fully understood. Monitoring systems must be designed carefully, to ensure there is no risk to personnel or property. Mathematical modeling of battery discharge data can reduce the extent and duration of a battery discharge test, while increasing the information produced. It reduces or even eliminates the need for independent load-banks by making possible accurate predictions of battery performance based on limited tests through the connected system load. It also makes possible accurate real-time predictions of battery performance during a discharge, yielding such dynamic information as time-to-run at present discharge rate.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127249131","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Power system controller in an intelligent telecom rectifier plant 智能电信整流装置中的电力系统控制器
U. Roth
{"title":"Power system controller in an intelligent telecom rectifier plant","authors":"U. Roth","doi":"10.1109/INTLEC.1992.268400","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268400","url":null,"abstract":"An intelligent power system controller (PSC) philosophy and concept for intelligent rectifier plants are presented. A modular, flexible control system is an ideal platform built for all necessary functions to fulfill all the requirements and the needs of owners, users, and operators of telecom plants. Changes or additions of functions are implemented only by software. High availability can be achieved by implemented fault tolerance. The reuse of high reliable, field installed and tested software blocks and functions is highly recommended.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127356409","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A manipulation and control scheme of paralleled diesel-generating sets in China 中国并联柴油发电机组操纵控制方案
Ren Wu
{"title":"A manipulation and control scheme of paralleled diesel-generating sets in China","authors":"Ren Wu","doi":"10.1109/INTLEC.1992.268413","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268413","url":null,"abstract":"Taking paralleled diesel generating sets as an example, the practical controller requirements of paralleled AC power supplies and the characteristics of parallel operation are analyzed. An automatic manipulation control scheme by means of a 'four-position' switcher is proposed. New ideas of load operation control and synchronizing control are presented. The novel optimal control scheme and fast phase-locked synchronizing control scheme are proposed. All research results are verified by digital simulation, micro-alternator simulation and set experiment, and are used in 300 kW diesel-generating sets.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127469390","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Parallel tuned resonant DC/DC converter topologies 并联调谐谐振DC/DC变换器拓扑结构
P. Jain
{"title":"Parallel tuned resonant DC/DC converter topologies","authors":"P. Jain","doi":"10.1109/INTLEC.1992.268460","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268460","url":null,"abstract":"The comparative performance of phase-shift modulated parallel tuned resonant DC/DC converter topologies is described. Three converter topologies (Type-A, Type-B and Type-C) are presented. The Type-A converter uses a series-tuned and parallel off-tuned resonant circuit. This converter topology exhibits near zero switching losses, at the expense of increased conduction losses. The Type-A converter is better suited for very high operating frequency and low input voltage with narrow range of variation. In the Type-B converter, both the series and parallel branches of the resonant circuit are tuned at the operating frequency. In this topology, 6 out of 8 switching losses are eliminated without additional penalty on the conduction losses. The Type-B converter is better suited for medium operating frequency and low input voltage with wide variation. The resonant circuit employed in the Type-C converter consists of a series inductor and a tuned parallel branch. In this topology, near zero switching losses are achieved without causing increased conduction losses. The Type-C converter topology is better suited for a very high operating frequency and high input voltage with wide variation.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121923855","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
On the design and experimentation of a high performance 25 A/48 V rectifier unit 高性能25a / 48v整流装置的设计与实验
J. Vieira, G. Gabiatti, I. Barbi
{"title":"On the design and experimentation of a high performance 25 A/48 V rectifier unit","authors":"J. Vieira, G. Gabiatti, I. Barbi","doi":"10.1109/INTLEC.1992.268390","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268390","url":null,"abstract":"A 25 A/48 V rectifier unit to be used as a battery charger for telecommunication applications is described. The unit is based on a modified version of the full-bridge zero-voltage switching pulse width modulated (FB-ZVS-PWM) DC/DC converter, which operates with no switching losses from no-load to full-load. The input stage is composed of a single-phase AC-to-DC converter with two diodes and two thyristors, which limit the inrush current, and it is used to disconnect the unit from the line in the case of malfunction. A 100-kHz operational prototype has been designed, fabricated and successfully tested in a laboratory. The overall measured efficiency is 94% at full load. Design procedure and experimental results are presented and discussed.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114872802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
On the use of duality in the dynamic analysis of switching power converters 对偶在开关电源变换器动态分析中的应用
A.S. Kislovski
{"title":"On the use of duality in the dynamic analysis of switching power converters","authors":"A.S. Kislovski","doi":"10.1109/INTLEC.1992.268452","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268452","url":null,"abstract":"Certain switching topologies produce a slowly varying current at their output. The injected-absorbed current analysis method, based on the slowly varying output voltage, can be used with these topologies if the roles of the output current and voltage are inversed. The approach is illustrated on a parallel resonant converter operating above resonances.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126290205","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A new power supply for fiber optic subscriber systems in transportable containers 一种用于可移动容器光纤用户系统的新型电源
S. Muroyama, N. Suzuki, H. Watanabe, M. Onozaki, Y. Kagawa
{"title":"A new power supply for fiber optic subscriber systems in transportable containers","authors":"S. Muroyama, N. Suzuki, H. Watanabe, M. Onozaki, Y. Kagawa","doi":"10.1109/INTLEC.1992.268433","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268433","url":null,"abstract":"Central terminal remote/terminal (CT/RT) fiber optic subscriber systems have been introduced to provide ISDN basic service. RT systems are installed in transportable containers or in customer buildings. A new RT system has been developed with a smaller container and a new power supply. The supply is highly efficient, small and lightweight. This is achieved by applying high-frequency conversion techniques. Test results show that the supply has sufficient capacity for use in RT systems installed in transportable containers.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"233 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125735783","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Field and laboratory studies to assess the state of health of valve-regulated lead acid batteries. I Conductance/capacity correlation studies 评估阀控铅酸电池健康状况的现场和实验室研究。1电导/容量相关性研究
D. Feder, T. Croda, K. S. Champlin, M. Hlavac
{"title":"Field and laboratory studies to assess the state of health of valve-regulated lead acid batteries. I Conductance/capacity correlation studies","authors":"D. Feder, T. Croda, K. S. Champlin, M. Hlavac","doi":"10.1109/INTLEC.1992.268438","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268438","url":null,"abstract":"Approximately 500 valve-regulated lead acid (VRLA) cells have been capacity tested, and measurements of conductance as well as conventional diagnostic parameters, such as float voltage and specific gravity, have been taken. Cells studied ranged from four to six years' service, from 200 to 1000 Ah in size and included a group of 6 V 200-Ah monoblocs. Although individual cell capacities ranged from 0% to 100%, there was essentially no correlation of capacity with the conventional diagnostic parameters of float voltage or specific gravity. By contrast, correlation of conductance with capacity was universally high, and sufficiently good to allow statistical prediction of capacity to be made from individual cell conductance values. Limited temperature test data, measured during discharge, show a significantly greater increase than would be expected in a vented (flooded) cell, of similar size and at similar rates. Additional data are needed to quantify this effect and determine necessary temperature correction factors for capacity discharge tests of VRLA cells.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"412 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115923754","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 31
Generalized modelling of constant frequency DC/DC resonant converter topologies 恒频DC/DC谐振变换器拓扑的广义建模
P. Jain, J. Quaicoe
{"title":"Generalized modelling of constant frequency DC/DC resonant converter topologies","authors":"P. Jain, J. Quaicoe","doi":"10.1109/INTLEC.1992.268444","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268444","url":null,"abstract":"A generalized model and an analysis of a constant frequency DC/DC resonant power converter are presented. Frequency-domain analysis is used to obtain generalized equations to describe the steady-state characteristics of the converter. Simulation results showing the effect of the leakage reactance of the high frequency transformer on the performance of the converter are presented. It is shown that the leakage reactance has a significant effect on the output voltage of the converter. A design example is provided to illustrate the use of the generalized equations and performance curves to design the converter.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131968537","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Introducing TMN concepts in the supervision and control of technologic plants 将TMN概念引入技术工厂的监督与控制
T. Milazzo, G. Monteleone, O. Pindaro, A. Vazzana
{"title":"Introducing TMN concepts in the supervision and control of technologic plants","authors":"T. Milazzo, G. Monteleone, O. Pindaro, A. Vazzana","doi":"10.1109/INTLEC.1992.268397","DOIUrl":"https://doi.org/10.1109/INTLEC.1992.268397","url":null,"abstract":"A supervision system is a very powerful management tool covering both the design of technological plants and their operation and maintenance. It is also a flexible support for diagnostic purposes, preventive maintenance and operational services planning. The strategy of using telecommunication management network (TMN) concepts allows an open approach in defining the network management architectures. This permits the integration of different TLC networks through a homogeneous interface. The adoption of such a strategy could significantly help in achieving cost reduction goals, permitting a unified management of the overall TLC environment.<<ETX>>","PeriodicalId":269215,"journal":{"name":"[Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131132112","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书