2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)最新文献

筛选
英文 中文
Massive-Integrated On-Chip Gel Actuators for Single Cell Manipulation 用于单细胞操作的大规模集成芯片凝胶致动器
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249362
Yuha Koike, Y. Yokoyama, T. Hayakawa
{"title":"Massive-Integrated On-Chip Gel Actuators for Single Cell Manipulation","authors":"Yuha Koike, Y. Yokoyama, T. Hayakawa","doi":"10.1109/MHS48134.2019.9249362","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249362","url":null,"abstract":"In this paper, we present driving method of gel actuator for single cell manipulation. We fabricated gel actuator by using temperature response gel on microfluidic chip with light absorbing pattern. We succeed in catching and stimulate Euglena by using gel actuators.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115431989","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
CNN-based cellular contractile force evaluation algorithm 基于cnn的细胞收缩力评估算法
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249351
Honghan Li, D. Matsunaga, T. Matsui, S. Deguchi
{"title":"CNN-based cellular contractile force evaluation algorithm","authors":"Honghan Li, D. Matsunaga, T. Matsui, S. Deguchi","doi":"10.1109/MHS48134.2019.9249351","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249351","url":null,"abstract":"Cells are known to sense mechanical cues in the surrounding environment to regulate their functions including proliferation, differentiation, and pro- inflammation. Despite numerous studies, signaling pathways underlying the cellular mechanosensing remain to be fully understood partly because of the lack of tools that enable a comprehensive screening, a major technical requirement for advancing molecular mechanobiology. We have developed a new technique, with which the cellular contractile forces are evaluated with a high-throughput analysis capability. Specifically, we fabricate a substrate by treating the surface of silicone elastomers, soft enough for individual cells to deform them, with oxygen plasm so that an oxide layer is created. The presence of the surficial oxide layer endows hydrophilic properties that allow cells/proteins to be attached and a mechanical stiffness relatively high compared to the underneath untreated elastomers. Consequently, the surface layer is buckled upon cellular contraction to form wrinkles reflecting the extent of the cellular contractility. These wrinkles are visualized in real time with conventional light microscopy without fiducial markers because the reference geometry of the surface is known to be planar. These features suggest that this technology is utilized as an “assay” to determine the relative magnitude of the contractility among cells on the same substrate or to determine if the contractility is altered upon molecular perturbations such as genetic manipulation and drug administration. For allowing high-throughput analysis, we developed a new CNN (Convolutional Neural Network) architecture, which allows us to extract the pattern of the wrinkles. Thus, cellular contractility can now be evaluated in a higher throughput manner compared to conventional techniques such as traction force microscopy.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122162838","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Torso Control System with A Sensory Safety Bar for a Standing Mobility Device 用于站立移动装置的带有传感安全杆的躯干控制系统
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249303
Yang Chen, Diego Felipe Paez Granados, Kenji Suzuki
{"title":"Torso Control System with A Sensory Safety Bar for a Standing Mobility Device","authors":"Yang Chen, Diego Felipe Paez Granados, Kenji Suzuki","doi":"10.1109/MHS48134.2019.9249303","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249303","url":null,"abstract":"With a focus on lower-body mobility impairment, we have developed a device for standing mobility: Qolo, which allows a user with full lower-body paralysis to displace around in a standing posture. In this paper, we propose a torso control system for allowing a hands-free operation through what we hypothesize to be a natural motion of the upper body. We introduce a new interface of motion control of the intended users through an ergonomic bar at the user's waist level with an array of force sensitive resistor (FSR) on the surface. We present the interface and the user's intention detection algorithms and evaluate it with a set of five healthy participants to examine and compare the motion interface with a traditional bi-dimensional joystick. Results show that users are able to adapt and use the proposed interface at a cost of longer training and task completion time; pointing out a higher level of skill required in compensation for achieving hands-free control.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"101 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132039860","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Adhesion Properties of Nanowire Surface Fastener 纳米线表面紧固件的粘附性能
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249283
Yuhki Toku, Y. Ju
{"title":"Adhesion Properties of Nanowire Surface Fastener","authors":"Yuhki Toku, Y. Ju","doi":"10.1109/MHS48134.2019.9249283","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249283","url":null,"abstract":"The power devices that are attracting attention in the recent development of electric vehicles, specifically, SiC and GaN power devices (power semiconductors) are expected as key technologies for the 21st century because of high current control and high-frequency operation. However, because of the operating temperature exceeds 300 degrees due to high power, thermal damage on the mounting part of the electronic package cannot be prevented by the present solder technique. We recently developed a metallic nanowire surface fastener (NSF) to resolve the abovementioned problems (Fig. 1). This fastener can be used to connect electronic components on a substrate at room temperature using the van der Waals force between each nanowire. The NSF would be expected to apply huge filed such as wearable devices, assembling of power devices in the inverter of electronic vehicle. This study demonstrates a 64-pin NSF that behaves like a ball grid array for application to actual electronic devices. Additionally, we demonstrate the fabrication of NSF on the flexible substrate. Through the comparison of above both, the adhesion mechanism of NSF is discussed in this present study. We also introduce how to control the adhesion morphology to improve the adhesion strength, electronic conductivity, and thermal conductivity of the NSF.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134569792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Elucidation of Velvet Hand Illusion using LABNIRS toward a New Haptic Display 基于LABNIRS的丝绒手错觉研究
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249323
Hiraku Komura, Hiroaki Kosuzi, M. Ohka
{"title":"Elucidation of Velvet Hand Illusion using LABNIRS toward a New Haptic Display","authors":"Hiraku Komura, Hiroaki Kosuzi, M. Ohka","doi":"10.1109/MHS48134.2019.9249323","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249323","url":null,"abstract":"VHI (Velvet Hand Illusion) is an illusion phenomenon to make someone feel a smooth sensation like velvet fabric and it is expected to be applied to haptic devices. To achieve this goal, it is very important to elucidate the mechanism of VHI. In this research, we investigate whether the brain activation related to VHI can be measured with NIRS. As a result, it is confirmed that the right middle frontal gyrus plays an important role in illusion occurrence which is same as the previous fMRI research.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115367858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A Basic Idea of Identifying the Stiffness of an Elastic Rod along its Backbone 确定弹性杆沿其主干的刚度的基本思路
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249349
H. Mochiyama
{"title":"A Basic Idea of Identifying the Stiffness of an Elastic Rod along its Backbone","authors":"H. Mochiyama","doi":"10.1109/MHS48134.2019.9249349","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249349","url":null,"abstract":"In this paper, we present a basic idea for identifying the stiffness along an elastic rod which is considered as being useful for capturing the stiffness of any long and slender structure such as an animal trunk or a biological micro/nano wire. After formulating the rod stiffness identification problem based on the rod theory, we consider the problem to identifying a spring constant of one degree-of-freedom (DOF) spring, and show a reasonable solution in an optimal manner based on the force balance equation as the simplest example of stiffness identification. Then, we show that this simple idea can be extended to the case of an elastic rod analogously where we have to identify three stiffness parameters with respect to bending in two different directions and twisting at each point on the backbone curve of an elastic rod.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"199 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115524751","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Frequency Response of Honeycomb Structured IPMC Actuator Fabricated through 3D Printing with Dispersion Liquid 分散液3D打印蜂窝结构IPMC致动器的频率响应
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249289
Hiroyuki Nabae, Asuka Ishiki, T. Horiuchi, K. Asaka, G. Endo, K. Suzumori
{"title":"Frequency Response of Honeycomb Structured IPMC Actuator Fabricated through 3D Printing with Dispersion Liquid","authors":"Hiroyuki Nabae, Asuka Ishiki, T. Horiuchi, K. Asaka, G. Endo, K. Suzumori","doi":"10.1109/MHS48134.2019.9249289","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249289","url":null,"abstract":"Ionic Polymer Metal Composites (IPMCs) have tremendous potential in the field of soft robotics, but their applications are currently limited by the restraints of the fabrication process. This paper introduces a fabrication method that produces thinner 3D structures, which is advantageous for use in micro soft robots. In this study, a honeycomb structured IPMC actuator was fabricated through 3D printing with dispersion liquid that utilizes water and propanol as a solvent. The frequency response of the prototype was measured to evaluate the fabricated microstructure and the results show that the proposed method to manufacture IPMC actuators with microstructures was successful.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117080229","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Magnetized Cell-robot Propelled by Regular Tetrahedron Magnetic Actuation System 正四面体磁致动系统驱动的磁化细胞机器人
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249288
Yuguo Dai, Yuanyuan Chen, Yanmin Feng, Dixiao Chen, Xue Bai, Lin Feng
{"title":"Magnetized Cell-robot Propelled by Regular Tetrahedron Magnetic Actuation System","authors":"Yuguo Dai, Yuanyuan Chen, Yanmin Feng, Dixiao Chen, Xue Bai, Lin Feng","doi":"10.1109/MHS48134.2019.9249288","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249288","url":null,"abstract":"The multiple degrees of freedom motion of micro-nano robots in three-dimensional space(3D) using magnetic field, has promising applications in biomedical field, ranging from drug delivery to cancer treatment with zero harm to human body. This paper presented a newly established magnetic system consist of four electromagnetic coils inspired by the regular tetrahedron structure and the cell-robot is proposed for the first time in the world. With the minimum number of coils, interference between electromagnets can be effectively avoided while the magnetic field flux intensity in multiple directions can reach 2.8T/m. Most importantly, the cell-robot which is based on the macrophage is proposed for the first time in the world, and can be transported precisely to the vicinity of cancer cells, then the cell-robot will actively phagocytose the cancer cells and eventually kill them, achieving the cancer treatment at the cellular level, which would be instructive for achieving cell-level treatment in the future.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129788237","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A sample carrier device for tensile characterization of ultra-thin and small biomembrane 一种用于超薄小生物膜拉伸表征的样品载体装置
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249304
H. Kumon, S. Sakuma, Yuichi Murozaki, F. Arai
{"title":"A sample carrier device for tensile characterization of ultra-thin and small biomembrane","authors":"H. Kumon, S. Sakuma, Yuichi Murozaki, F. Arai","doi":"10.1109/MHS48134.2019.9249304","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249304","url":null,"abstract":"We have previously developed a tensile characterization system of ultra-thin and small biomembrane. In this system, we should align the membrane at the tip of the force sensor clamp having microhole array to fix the membrane sample. Since the throughput of the measurement depends on the alignment time, the method of sample alignment enables us to fix the sample with the short time of several minutes is highly desired. Therefore, we propose a carrier device utilizing a hollow fiber that can put the membrane sample. As a result, the alignment time was less than 1 minutes which was approximately 10 times faster than the previous methodee.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123716008","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Photoelastic stress measurement in real-time for surgery simulator using gel materials 用凝胶材料进行手术模拟器的实时光弹性应力测量
2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS) Pub Date : 2019-12-01 DOI: 10.1109/MHS48134.2019.9249277
Daichi Yamada, Simon Hori, C. Oka, J. Sakurai, S. Hata
{"title":"Photoelastic stress measurement in real-time for surgery simulator using gel materials","authors":"Daichi Yamada, Simon Hori, C. Oka, J. Sakurai, S. Hata","doi":"10.1109/MHS48134.2019.9249277","DOIUrl":"https://doi.org/10.1109/MHS48134.2019.9249277","url":null,"abstract":"In recent years, minimally invasive treatment aimed at reducing the physical and mental burden of patients as well as treating diseases has attracted attention. Catheter surgery is one of the minimally invasive treatments. This surgical technique can reduce invasion compared to incision and replacement with artificial vessels. Furthermore, it is known to be superior in terms of safety. On the other hand, in catheter surgery, visual information is limited to only a two-dimensional image by an X-ray camera. Therefore, there is a problem that stress is applied to the blood vessel wall and it is damaged, so doctors are required the skill of catheter surgery. This study is proposed a catheter surgery simulator that visualizes the stress applied to the blood vessel wall in realtime using photoelasticity. The blood vessel model used for the surgery simulator focused on PVA hydrogel. Previous experiments by our group have shown that PVA hydrogel can be applied to a surgical simulator. This study has developed an image processing program to measure stress in real-time. It has verified that the application to a surgery simulator is possible by this image processing program.","PeriodicalId":264161,"journal":{"name":"2019 International Symposium on Micro-NanoMechatronics and Human Science (MHS)","volume":"212 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115226554","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书