2018 International Conference on Biomedical Engineering and Applications (ICBEA)最新文献

筛选
英文 中文
Design and Simulation of a CMOS Slew-Rate Enhanced OTA to Drive Heavy Capacitive Loads 驱动大容量负载的CMOS回转速率增强型OTA设计与仿真
2018 International Conference on Biomedical Engineering and Applications (ICBEA) Pub Date : 2018-07-01 DOI: 10.1109/ICBEA.2018.8471744
L. M. C. Freitas, F. M. Dias, G. Meynants, A. Xhakoni
{"title":"Design and Simulation of a CMOS Slew-Rate Enhanced OTA to Drive Heavy Capacitive Loads","authors":"L. M. C. Freitas, F. M. Dias, G. Meynants, A. Xhakoni","doi":"10.1109/ICBEA.2018.8471744","DOIUrl":"https://doi.org/10.1109/ICBEA.2018.8471744","url":null,"abstract":"Flicker noise is one of the main noise contributors in CMOS Image Sensors. After great effort from universities and industry in reducing thermal noise, in modern CMOS imagers the bottleneck in achieving lower noise performance is now flicker noise. This paper presents a new method to reduce the flicker noise contribution in the overall sensor noise budget by means of reducing the time for Double Sampling, so that it more effectively filters the flicker noise spectrum introduced by the pixel source follower amplifier. In addition, this paper also proposes a way to promote and ensure no column induced lag from column readout circuitry through strong and stable references. The proposed amplifier circuit buffers the reference voltage while Double Sampling operation performed in the analogue domain, is taking place. It not only shortens the time between samples, but also reduces the current consumption, reducing part of the sensor power heat dissipation. Finally, the proposed architecture can be used in different applications where high resolution and stable references are needed, e.g. to supply the references for massive column parallel analogue circuits which are typical in modern CMOS Image Sensor designs. The design and simulation of the proposed high Slew-Rate driver circuit are verified with a circuit containing 3000 readout columns.","PeriodicalId":260321,"journal":{"name":"2018 International Conference on Biomedical Engineering and Applications (ICBEA)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126692464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A Smart Wireless System for Modeling Visual Searching Behavior and Assessing Reaction Time in Sports and Rehabilitation Activities 运动和康复活动中视觉搜索行为建模和反应时间评估的智能无线系统
2018 International Conference on Biomedical Engineering and Applications (ICBEA) Pub Date : 2018-07-01 DOI: 10.1109/ICBEA.2018.8471734
Boubaker Ben Ali, Olfa Oueslati, E. Dugas
{"title":"A Smart Wireless System for Modeling Visual Searching Behavior and Assessing Reaction Time in Sports and Rehabilitation Activities","authors":"Boubaker Ben Ali, Olfa Oueslati, E. Dugas","doi":"10.1109/ICBEA.2018.8471734","DOIUrl":"https://doi.org/10.1109/ICBEA.2018.8471734","url":null,"abstract":"The implementation of wireless electronic simulation signals, as an approach for visual searching behavior recognition, is not a straightforward task. This paper discusses modeling human interactions in a real game by wireless electronic visual stimuli, which could led Human Computer Interaction (HCI) researchers in sports science and education science to take benefits from using electronic models, stimuli and measure features. Methodology standardization would allow the comparison of results, the reliability of findings and the easy integration of the various behavior recognition systems created. The aim of this paper is: First, to present a leading validation experimental process for B-percept behavior modeling and decision- making and assessing system. Second, to provide directions on which the future research efforts, for modeling and assessing behavior, using HCI should be focused on.","PeriodicalId":260321,"journal":{"name":"2018 International Conference on Biomedical Engineering and Applications (ICBEA)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116966240","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Image Denoise FPGA Implementation Using a Moving Average Filter with Contour Detection 基于移动平均滤波器和轮廓检测的图像去噪FPGA实现
2018 International Conference on Biomedical Engineering and Applications (ICBEA) Pub Date : 2018-07-01 DOI: 10.1109/ICBEA.2018.8471740
Ricardo Jardim, F. M. Dias
{"title":"Image Denoise FPGA Implementation Using a Moving Average Filter with Contour Detection","authors":"Ricardo Jardim, F. M. Dias","doi":"10.1109/ICBEA.2018.8471740","DOIUrl":"https://doi.org/10.1109/ICBEA.2018.8471740","url":null,"abstract":"A Moving Average Filter should be among the first filters, if not the first, one should consider when speed, good precision and low to medium hardware resources are what is required for implementing image noise reduction on a physical device. The technique is fairly simple to implement, but if taken a straight forward approach, the result will be a blurry image which is undesirable. Since the human eye is most sensitive to the sharp tone transition, we introduced a contour detection technique. Because the inherently lack of floating point representation, except for the most modern FPGA's versions, all the calculations were done in fixed point. Also, images used were scaled up to 10×103colour levels (a bit higher than 213bits). Real results of double precision 64-bit were achieved through Matlab and then compared to a Zynq-7000 FPGA using 64-bit fixed point calculations. The error difference obtained between both implementations was 1×10−4.","PeriodicalId":260321,"journal":{"name":"2018 International Conference on Biomedical Engineering and Applications (ICBEA)","volume":"87 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115881547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Hybrid Brain Computer Interface for Movement Control of Upper Limb Prostheses 用于上肢假体运动控制的脑机混合接口
2018 International Conference on Biomedical Engineering and Applications (ICBEA) Pub Date : 2018-07-01 DOI: 10.1109/ICBEA.2018.8471729
Heba Aly, S. Youssef, Cherine Fathy
{"title":"Hybrid Brain Computer Interface for Movement Control of Upper Limb Prostheses","authors":"Heba Aly, S. Youssef, Cherine Fathy","doi":"10.1109/ICBEA.2018.8471729","DOIUrl":"https://doi.org/10.1109/ICBEA.2018.8471729","url":null,"abstract":"Electroencephalography (EEG) and Electromyography (EMG) signals are playing significant role in controlling bio-robotics applications, such as prostheses. Brain Computer Interfaces (BCIs) for amputees allow them to use their remaining functionalities as control possibilities by turning brain signals into commands for external devices. However, BCIs that use the EEG signals alone are not yet fully acceptable in bio-robotic applications. Myoelectric control systems use EMG signals recorded on the residual muscles of amputated limbs to control prosthesis, but the residual muscles cannot often provide enough signal to control a multiple degrees of freedom prosthetics. This paper introduces a new hybrid BCI model that integrates EEG and EMG signal processing with machine learning models to efficiently improve classification accuracy and increase the control performance of different upper limb movements for above elbow amputees. Experiments have been carried out on a large dataset of 64 channel EEG signals, combined with 32 channel surface EMG (sEMG) signals, acquired simultaneously from above-elbow amputees to decode five hand and wrist motions. Classification accuracy is used for evaluating the classification performance with 5-fold cross validation. Experimental results demonstrate that the proposed model achieves a high classification accuracy, exceeding 98.8%, using 6th order Autoregressive (AR) model coefficients with three proposed combined set of features from time domain, frequency domain and entropies. This suggested model outperforms previously proposed models in the literature with up to 8.9% improvement ratio; this implies that Hybrid-BCI can be reliably used to improve the control performance of upper limb movements. Furthermore, the model may be easily applied into real-time hybrid BCI application.","PeriodicalId":260321,"journal":{"name":"2018 International Conference on Biomedical Engineering and Applications (ICBEA)","volume":"684 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122464575","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
A Real-Time QRS Complex Detector Based on Discrete Wavelet Transform and Adaptive Threshold as Standalone Application on ARM Microcontrollers 基于离散小波变换和自适应阈值的实时QRS复杂检测器在ARM单片机上的独立应用
2018 International Conference on Biomedical Engineering and Applications (ICBEA) Pub Date : 2018-07-01 DOI: 10.1109/ICBEA.2018.8471741
Victor H. Rodriguez, C. Medrano, I. Plaza
{"title":"A Real-Time QRS Complex Detector Based on Discrete Wavelet Transform and Adaptive Threshold as Standalone Application on ARM Microcontrollers","authors":"Victor H. Rodriguez, C. Medrano, I. Plaza","doi":"10.1109/ICBEA.2018.8471741","DOIUrl":"https://doi.org/10.1109/ICBEA.2018.8471741","url":null,"abstract":"The electrocardiogram (ECG) is one of the most used tools to detect the health state of the heart. The QRS complex is an important waveform in an ECG signal and it serves as reference point for most ECG signal processing algorithms. In this paper a real-time QRS complex detector based on discrete wavelet transform (DWT) is proposed. In contrast with other algorithms, ours is able to automatically select the detail coefficients that will be used to detect the QRS complex after applying the DWT to the signal. The algorithm was compared with other published methods and evaluated with two datasets, one of them with arrhythmia and the other in healthy conditions. The results for the signals with arrhythmia were 99.30% for sensitivity, 99.61% for positive predictivity and 1.12% for error detection rate, while in the signals in healthy conditions the values were of 99.95%, 99.98% and 0.0006% respectively. Finally, the algorithm was implemented on an ARM microcontroller showing its real-time processing capability","PeriodicalId":260321,"journal":{"name":"2018 International Conference on Biomedical Engineering and Applications (ICBEA)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123524642","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书