R. Fernández, S. Gallego, F. J. Martínez, A. Márquez, I. Pascual, A. Beléndez
{"title":"Generation of diffractive optical elements onto photopolymer using liquid crystal on silicon displays","authors":"R. Fernández, S. Gallego, F. J. Martínez, A. Márquez, I. Pascual, A. Beléndez","doi":"10.1109/WIO.2017.8038111","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038111","url":null,"abstract":"In recent years, the optical storage and optical information processing technologies based on holographic and photonic techniques are suffering a huge improvement. On the other hand, Spatial Light Modulators (SLMs) based on LCoS microdisplays (PA-LCoS) open new possibilities to modulate the wavefront of a light beam. PA-LCoS are high resolution reflective devices which make possible the generation of Diffractive Optical Elements (DOE) with many important applications in photonics, communications of optical information processing, whenever it exists the possibility to have a recording material with the optimum characteristics for each application. Recently it is being explored the incorporation of photopolymers, initially used for holographic recording and data storage applications, to fabricate DOEs. Working with a setup based on a LCoS display as a master, we can store complex DOE, such as blazed gratings or diffractive lenses onto the photopolymers. We used a coverplating and index matching system on the material to avoid the influence of the thickness variation on the transmitted light.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125453475","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Tentrup, W. Luiten, P. Hooijschuur, R. van der Meer, P. Pinkse
{"title":"Two high-dimensional cartesian bases for quantum key distribution","authors":"T. Tentrup, W. Luiten, P. Hooijschuur, R. van der Meer, P. Pinkse","doi":"10.1109/WIO.2017.8038181","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038181","url":null,"abstract":"Quantum Key Distribution (QKD) provides a secure way of generating shared cryptographic keys between a sender (Alice) and a receiver (Bob). The original BB84 protocol uses a two-dimensional polarization basis, limiting the information content of a single photon to 1 bit. Using the transverse position of single photons as one basis and the Fourier space as a second basis, one can construct a pair of mutually unbiased higher-dimensional bases. This improves not only the security of the protocol, but also the key generation rate. We present experimental results with a Spatial-Light-Modulator-based encoding scheme employing two nearly orthogonal alphabets with on the order of 103 symbols each and an information content of about 10 bit.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121072281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Partially coherent optical diffraction tomography for label-free quantitative microscopy","authors":"J. Soto, J. Rodrigo, T. Alieva","doi":"10.1109/WIO.2017.8038185","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038185","url":null,"abstract":"In this work we present a tomographic technique for label-free quantitative microscopy that exploits the benefits of the partially coherent illumination. In contrast to conventional holographic techniques based on the coherent optical diffraction tomography (C-ODT), our approach uses an inexpensive non-interferometric setup comprising an electrically tunable lens and low spatially coherent illumination. This setup provides the refocusing needed for axially scan the sample and eventually producing a 3D stack of intensity images. Moreover, the partially coherent illumination avoids speckle noise, which plagues the C-ODT imaging methods. This technique has been developed for optically weak and almost non-absorbing objects that meet the conditions of the first Born approximation. We experimentally demonstrate the capability of the proposed technique by recovering the 3D refractive index distribution of biological samples such as blood cells and diatoms. The results are similar to those obtained by the C-ODT but using a simplified reconstruction process and a refocusing module that can be easily included in commercial widefield microscopes.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116643355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
F. Pla, P. Latorre-Carmona, E. Salvador-Balaguer, B. Javidi
{"title":"Gesture recognition using Integral Imaging","authors":"F. Pla, P. Latorre-Carmona, E. Salvador-Balaguer, B. Javidi","doi":"10.1109/WIO.2017.8038182","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038182","url":null,"abstract":"In this paper we present some results summarizing our previous work during the last few years in the analysis of Synthetic Aperture Integral Imaging (SAII) performance for human gesture recognition, with a particular emphasis in its accuracy in the presence of occlusions, also when comparing it with sensors and strategies that are commonly used for these tasks, like the RGB-D sensors. Experiments show that its performance compares favorably against monocular imaging and to RGB-D sensors and that gesture classification results support the increase in performance for SAII particularly under partial occlusions.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131187624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Spatiotemporal imaging of THz wave propagation: Polaritonics versus near-field imaging","authors":"H. Merbold","doi":"10.1109/WIO.2017.8038178","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038178","url":null,"abstract":"Two recently developed methods that allow visualizing the interaction of THz radiation with arbitrary structures, namely polaritonics and near-field imaging, are reviewed and compared. THz polaritonics, which relies on complex amplified laser systems, allows single-shot image acquisition in a plane perpendicular to the structures. THz near-field imaging, on the other hand, requires only femtosecond oscillators but is a slower raster scanning technique providing images parallel to the structure plane.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"79 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114118616","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Son, Hyoung Lee, Beom-Ryeol Lee, Ji-Sun Byeon, M. Park
{"title":"Holographic and light field displays: What are the differences?","authors":"J. Son, Hyoung Lee, Beom-Ryeol Lee, Ji-Sun Byeon, M. Park","doi":"10.1109/WIO.2017.8038184","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038184","url":null,"abstract":"Holographic and light field displays are currently the most researched 3-D imaging technologies. It is considered that the two imaging provide continuous parallaxes so that they can create a natural viewing environment. The main difference of the two imaging lies in their light fields in front of the display panel. The light fields in holographic displays are formed by phase conjugated rays from each hologram point and the light field display by an ever expanding fan beam from each pixel.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"41 3","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121006853","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Three-dimensional fluorescence imaging based on digital holography","authors":"O. Matoba, X. Quan, Y. Awatsuji","doi":"10.1109/WIO.2017.8038177","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038177","url":null,"abstract":"Fluorescence imaging is one of the important tools for biological field. For three-dimensional (3D) visualization of the fluorescence, we present two approaches. One is the common-path off-axis incoherent digital holography using dual gratings on dual Fresnel lenses. The other method is the image recovery of a defocused 2D fluorescence image by using the defocused distance obtained from the 3D phase imaging by off-axis digital holography. For the image recovery, the fluorescence bead image is blurred by the spherical aberration and wave propagation by the defocused distance. Spherical aberration is eliminated by Zernike polynomial and the defocused distance is obtained by numerical refocusing from the phase measurement in an off-axis digital holography. Both techniques can be applied to biological imaging.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126071864","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optical dot gain information","authors":"T. Fournel","doi":"10.1109/WIO.2017.8038112","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038112","url":null,"abstract":"Optical dot gain, a non-deterministic phenomenon to be taken into account when modeling halftone print reproduction, is revisited under information theory. Its impact is quantified at different scales in an attempt to better understand the dedicated “n-value”.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130291905","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Carnicer, I. Juvells, D. Maluenda, R. Martínez-Herrero
{"title":"Polarization measurements in the focal area","authors":"A. Carnicer, I. Juvells, D. Maluenda, R. Martínez-Herrero","doi":"10.1109/WIO.2017.8038109","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038109","url":null,"abstract":"Linear polarizers are present in all kind of optical systems. These devices behave as vector projectors in the polarization direction assuming quasi-transverse beams in the paraxial domain. Nevertheless, the performance of polarizers used in combination with focused beams requires a more in-depth analysis. Understanding this behavior is essential in microscopy applications because of the non-negligible longitudinal irradiance in the focal plane. In this talk, we discuss the effect of polarizers on the focused electric field. Experimental results show a good agreement with theoretical predictions based on considering linear polarizers as anisotropic plates.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133988170","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"3D tracking of micro object in liquid by parallel phase-shifting digital holographic microscope","authors":"Y. Awatsuji, T. Fukuda, P. Xia, O. Matoba","doi":"10.1109/WIO.2017.8038107","DOIUrl":"https://doi.org/10.1109/WIO.2017.8038107","url":null,"abstract":"The authors describe three-dimensional (3D) motion pictures of dynamic micro objects obtained by parallel phase-shifting digital holographic microscope. The microscope consisted of a Mach-Zehnder interferometer, an inverted magnification optical system, a continuous wave laser, and a polarization imaging camera. An alum crystal sinking in aqueous solution of alum was set for a dynamic micro object The shape and the size of the crystal were approximately regular octahedron and about 25μm in a side, respectvely. The 3D motion picture of the sinking alum crystal at the rate of 60 frames per second was obtained by the parallel phase-shifting digital holographic microscope. Also, the 3D tracking plot of the alum crystal sinking in aqueous solution of alum was achieved from the 3D motion picture.","PeriodicalId":258459,"journal":{"name":"2017 16th Workshop on Information Optics (WIO)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116460715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}