T. Stevenson, T. Wines, David Martin, W. Vickers, M. Laws
{"title":"HotSense: a high temperature piezoelectric platform for sensing and monitoring in extreme environments (Conference Presentation)","authors":"T. Stevenson, T. Wines, David Martin, W. Vickers, M. Laws","doi":"10.1117/12.2222139","DOIUrl":"https://doi.org/10.1117/12.2222139","url":null,"abstract":"Effective monitoring of asset integrity subject to corrosion and erosion while minimizing the exposure of personnel to difficult and hazardous working environments has always been a major problem in many industries. One solution of this problem is permanently installed ultrasonic monitoring equipment which can continuously provide information on the rate of corrosion or cracking, even in the most severe environments and at extreme temperatures to prevent the need for shutdown. Here, a permanently installed 5 MHz ultrasonic monitoring system based on our HotSense® technology is designed and investigated. The system applicability for wall thickness, crack monitoring and weld inspection in high temperature environments is demonstrated through experimental studies on a range of Schedule 40 pipes at temperatures up to 350 °C continuously. The applicability for this technology to be distributed to Aerospace and Nuclear sectors are also explored and preliminary results discussed.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116064533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Oil pipeline geohazard monitoring using optical fiber FBG strain sensors (Conference Presentation)","authors":"Andres Salazar-Ferro, A. Mendez","doi":"10.1117/12.2219542","DOIUrl":"https://doi.org/10.1117/12.2219542","url":null,"abstract":"Pipelines are naturally vulnerable to operational, environmental and man-made effects such as internal erosion and corrosion; mechanical deformation due to geophysical risks and ground movements; leaks from neglect and vandalism; as well as encroachments from nearby excavations or illegal intrusions. The actual detection and localization of incipient and advanced faults in pipelines is a very difficult, expensive and inexact task. Anything that operators can do to mitigate the effects of these faults will provide increased reliability, reduced downtime and maintenance costs, as well as increased revenues. This talk will review the on-line monitoring of an extensive network of oil pipelines in service in Colombia using optical fiber Bragg grating (FBG) strain sensors for the measurement of strains and bending caused by geohazard risks such as soil movements, landslides, settlements, flooding and seismic activity. The FBG sensors were mounted on the outside of the pipelines at discrete locations where geohazard risk was expected. The system has been in service for the past 3 years with over 1,000 strain sensors mounted. The technique has been reliable and effective in giving advanced warning of accumulated pipeline strains as well as possible ruptures.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"107 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124129339","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Hwang, Jungsoo Nam, Qi Shen, Sarah Trabia, J. Suhr, Dong‐Chan Lee, K. Kim
{"title":"Property modification of Nafion via polymer blending with ethylene vinyl alcohol \"polyimide\" (Conference Presentation)","authors":"T. Hwang, Jungsoo Nam, Qi Shen, Sarah Trabia, J. Suhr, Dong‐Chan Lee, K. Kim","doi":"10.1117/12.2220448","DOIUrl":"https://doi.org/10.1117/12.2220448","url":null,"abstract":"The blended ion exchange membrane between Nafion and ethylene vinyl alcohol (EVOH) was used for fabrication of the ionic polymer–metal composite (IPMC) to redeem inherent drawbacks of Nafion such as high cost or environment-unfriendliness. EVOH solution was blended in Nafion solution by a volume ratio of 15 and 30 % membranes were prepared through solution casting method. The prepared blended Nafion membranes can be fabricated IPMCs with deposition of platinum electrode onto its surface without crack or delamination. The surface resistance of all prepared IPMCs is measured through 2 point probe. This study investigated the chemical structure and thermal properties of prepared membranes. Moreover, we characterized the cross-section morphology and studied the electromechanical performances (displacement and blocking force) of prepared IPMC actuators. The IPMC actuators with proposed blended Nafion membranes were demonstrated comparable electromechanical performance by significantly reducing the content of Nafion.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115182652","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Hwang, V. Palmre, T. Stalbaum, Qi Shen, Sarah Trabia, K. Kim
{"title":"IPMC cilia system for artificial muscle applications (Conference Presentation)","authors":"T. Hwang, V. Palmre, T. Stalbaum, Qi Shen, Sarah Trabia, K. Kim","doi":"10.1117/12.2220447","DOIUrl":"https://doi.org/10.1117/12.2220447","url":null,"abstract":"Artificial muscle (AM) technology is an excellent candidate for creating cilia-based structures for bio-inspired locomotion, maneuvering, and acoustic systems. We developed an AM based cilia fiber which are soft, flexible, easily shaped and low power consumption. The developed cilium has a diameter of around 200 µm and prepared through polymer injection technique. Nafion was used for base polymer for cilia and fabricated IPMCs via platinum electroless plating process. The prepared cilia were characterized by Fourier transform infrared spectroscopy, differential scanning calorimetry, and thermogravimetric analysis. The 2 point probe was conducted to measure electrode surface resistance of prepared IPMCs. We further characterized the cross-sectional morphology and studied the electromechanical performances (displacement and blocking force) of the prepared IPMC actuators. Also we created prototype mm-sized AM fiber cilia array (3x20) and tested the actuation of AM cilia fiber under external electric field.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115627521","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nondestructive testing and hardness measurement based on contact resonance of piezoelectric cantilevers (Conference Presentation)","authors":"Faxin Li, Ji Fu","doi":"10.1117/12.2218592","DOIUrl":"https://doi.org/10.1117/12.2218592","url":null,"abstract":"A suitable defect identification parameter is very important in the field of nondestructive testing (NDT). In this work, we proposed a NDT method which detects the sample’s local contact stiffness (LCS) based on the contact resonance of a piezoelectric cantilever. Firstly, through finite element analysis we showed that LCS is quite sensitive to typical defects including debonding, voids, cracks and inclusions, making it a good identification parameter. Secondly, a homemade NDT system containing a piezoelectric unimorph cantilever was assembled to detect the sample’s LCS by tracking the contact resonance frequency (CRF) of the cantilever-sample system based on strain signals. Testing results indicated that this NDT system could detect the above mentioned defects efficiently. The cantilever-stiffness dependent detection sensitivity was specially investigated and the stiffer cantilevers were found to be more sensitive to small defects. Then, a piezoelectric bimorph cantilever was fabricated and the electromechanical impedance, other than the strain signals, was measured to track the CRF of the cantilever-system. The LCS is then derived by using the equivalent-circuit model. The electromechanical impedance based NDT system is more compact and can be further developed to be a portable device. Finally, a Vicker indenter is fabricated onto the bimorph tip and the contact area is derived from the measured LCS. Thus the NDT system turns to be a hardness tester without any optical devices. It is very useful for in-situ testing or testing on inner surfaces where conventional hardness tester is not applicable.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"353 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122789210","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design of a bullet beam pattern of a micro ultrasound transducer (Conference Presentation)","authors":"Y. Roh, Seongmin Lee","doi":"10.1117/12.2219568","DOIUrl":"https://doi.org/10.1117/12.2219568","url":null,"abstract":"Ultrasonic imaging transducer is often required to compose a beam pattern of a low sidelobe level and a small beam width over a long focal region to achieve good image resolution. Normal ultrasound transducers have many channels along its azimuth, which allows easy formation of the sound beam into a desired shape. However, micro-array transducers have no control of the beam pattern along their elevation. In this work, a new method is proposed to manipulate the beam pattern by using an acoustic multifocal lens and a shaded electrode on top of the piezoelectric layer. The shading technique split an initial uniform electrode into several segments and combined those segments to compose a desired beam pattern. For a given elevation width and frequency, the optimal pattern of the split electrodes was determined by means of the OptQuest-Nonlinear Program (OQ-NLP) algorithm to achieve the lowest sidelobe level. The requirement to achieve a small beam width with a long focal region was satisfied by employing an acoustic lens of three multiple focuses. Optimal geometry of the multifocal lens such as the radius of curvature and aperture diameter for each focal point was also determined by the OQ-NLP algorithm. For the optimization, a new index was devised to evaluate the on-axis response: focal region ratio = focal region / minimum beam width. The larger was the focal region ratio, the better was the beam pattern. Validity of the design has been verified through fabricating and characterizing an experimental prototype of the transducer.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131613015","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Self-repairing composite walls for pressurized space habitats","authors":"C. Dry","doi":"10.1117/12.2218553","DOIUrl":"https://doi.org/10.1117/12.2218553","url":null,"abstract":"A most important factor for human occupied habitats in space is to ensure that the pressurized habitat does not lose pressure catastrophically by the penetration of space debris or micrometeorites through the wall and into the pressurized space. Regenerative self repairing composites used for the space station habitat to prevent loss of pressure was demonstrated in tests The wall sample had ambient pressurized on one side with vacuum on the other, then was punctured all the way through; the pressure reading went from -26 inches of mercury to -26 inches and stayed there indefinitely. There was no loss of pressure! This will be a game changer for space habitat design. This represents a proposed test bed experimental effort on the International Space Station for self repairing regenerative walls of pressurized habitats, supported by significant puncture over vacuum and puncture testing performed to date, which will provide NASA with an innovative new light weight multi-hit superior Astronaut Protective Wall solution for pressurized space habitats.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114339584","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Junjie Liu, G. Mao, Xiaoqiang Huang, Zhanan Zou, S. Qu, Peng Wang
{"title":"Electromechanical behavior of a novel dielectric elastomer sensor for compressive force detection (Conference Presentation)","authors":"Junjie Liu, G. Mao, Xiaoqiang Huang, Zhanan Zou, S. Qu, Peng Wang","doi":"10.1117/12.2218769","DOIUrl":"https://doi.org/10.1117/12.2218769","url":null,"abstract":"Dielectric elastomers (DEs) have been extensively studied as DE actuators, DE generators, and DE sensors. Compared with DE actuators and generators, DE sensing application has the advantage that it is no need for high voltage. However, to realize the high sensitivity of the DE sensor, a well-designed structure is essential. A typical DE sensor consists of DE membrane covered by compliant electrodes on both sides. Expanding in the area and shrinking in the thickness of DE membrane subjected to external force will lead to the increasement of the capacitance. We propose a novel DE sensor to detect compressive force. The DE sensor consists of three layers. The two layers of outside can penetrate each other to deform the middle layer and achieve high sensitivity for compressive force measurement. This sensor consists of a series of sensor elements made of DE membrane with out-of-plane deformation. Each sensor element experiences highly inhomogeneous large deformation to obtain high sensitivity. We conduct the experiment to optimize the performance of the sensor element, and also the corresponding theoretical analysis is developed. The effects of the prestretches and the aspect ratios of the sensor element on the sensitivity are achieved. The soft sensor composed of a series of such sensor elements may comply with complicated surfaces and can be used to detect both the total value and the distribution of the compressive force exerted on the surface. Furthermore, the reliability of the sensor element is studied by additional experimental investigation. The experiment shows that the sensor element operates steadily after 2000 cyclic loadings. This study provides guidance for the design and performance analysis of soft sensors. This work has been published in the Journal of Applied Mechanics, 82(10), No. 101004 (2015).","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114851655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
John Day, H. Yoon, Jaehwan Kim, Sang H. Choi, K. D. Song
{"title":"Simulation study of a high power density rectenna array for biomedical implantable devices","authors":"John Day, H. Yoon, Jaehwan Kim, Sang H. Choi, K. D. Song","doi":"10.1117/12.2222603","DOIUrl":"https://doi.org/10.1117/12.2222603","url":null,"abstract":"The integration of wireless power transmission devices using microwaves into the biomedical field is close to a practical reality. Implanted biomedical devices need a long lasting power source or continuous power supply. Recent development of high efficiency rectenna technology enables continuous power supply to these implanted devices. Due to the size limit of most of medical devices, it is imperative to minimize the rectenna as well. The research reported in this paper reviews the effects of close packing the rectenna elements which show the potential of directly empowering the implanted devices, especially within a confined area. The rectenna array is tested in the X band frequency range.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132259394","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nonlinear phased array imaging","authors":"A. Croxford, Jingwei Cheng, J. Potter","doi":"10.1117/12.2224744","DOIUrl":"https://doi.org/10.1117/12.2224744","url":null,"abstract":"A technique is presented for imaging acoustic nonlinearity within a specimen using ultrasonic phased arrays. Acoustic nonlinearity is measured by evaluating the difference in energy of the transmission bandwidth within the diffuse field produced through different focusing modes. The two different modes being classical beam forming, where delays are applied to different element of a phased array to physically focus the energy at a single location (parallel firing) and focusing in post processing, whereby one element at a time is fired and a focused image produced in post processing (sequential firing). Although these two approaches are linearly equivalent the difference in physical displacement within the specimen leads to differences in nonlinear effects. These differences are localized to the areas where the amplitude is different, essentially confining the differences to the focal point. Direct measurement at the focal point are however difficult to make. In order to measure this the diffuse field is used. It is a statistical property of the diffuse field that it represents the total energy in the system. If the energy in the diffuse field for both the sequential and parallel firing case is measured then the difference between these, within the input signal bandwidth, is largely due to differences at the focal spot. This difference therefore gives a localized measurement of where energy is moving out of the transmission bandwidth due to nonlinear effects. This technique is used to image fatigue cracks and other damage types undetectable with conventional linear ultrasonic measurements.","PeriodicalId":255403,"journal":{"name":"SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring","volume":"9805 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129712837","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}